Effect of reference electrode in the nanoFET (field-effect transistor)-based biosensor experiment

被引:1
|
作者
Seo, Yeong-Tai [1 ,2 ]
Jang, Kuk Jin [2 ]
Lee, Min-Ho [2 ]
Seong, Woo-Kyeong [2 ]
Lee, Kook-Nyung [2 ]
Kim, Yong-Kweon [1 ]
机构
[1] Seoul Natl Univ, Sch Elect Engn & Comp Sci, Seoul 151744, South Korea
[2] KETI, Med IT Convergence Res Ctr, Songnam 463816, Gyeonggi Do, South Korea
来源
MICRO & NANO LETTERS | 2014年 / 9卷 / 12期
关键词
SENSORS;
D O I
10.1049/mnl.2014.0405
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The reference electrode in an electrolyte solution affects the surface potential of the nanoFET (field-effect transistor) channel which can result in a false signal to be measured in the FET channel during bio- and chemical sensing experiments. In this reported work, it was demonstrated that different sensing results that were obtained were affected by the choice of the reference electrode through a pH and ion concentration sensing experiment. Three types of reference electrodes were compared: the SCE (saturated calomel reference electrode), the Ag/AgCl tube and the integrated Ag/AgCl electrode. The pH sensitivity equivalent to the surface potential was evaluated: 32.3, 34.6 and 16.3 mV/pH in the case of the SCE, the refillable tube type Ag/AgCl and the integrated Ag/AgCl, respectively.
引用
收藏
页码:874 / 876
页数:3
相关论文
共 50 条
  • [1] MINIATURIZED REFERENCE ELECTRODE BASED ON A PERCHLORATE-SELECTIVE FIELD-EFFECT TRANSISTOR
    POTTER, W
    DUMSCHAT, C
    CAMMANN, K
    ANALYTICAL CHEMISTRY, 1995, 67 (24) : 4586 - 4588
  • [2] Graphene Field-Effect Transistor for Biosensor
    Matsumoto, Kazuhiko
    Hayashi, Ryota
    Kanai, Yasushi
    Inoue, Koichi
    Ono, Takao
    2016 23RD INTERNATIONAL WORKSHOP ON ACTIVE-MATRIX FLATPANEL DISPLAYS AND DEVICES (AM-FPD), 2016, : 45 - 46
  • [3] FIELD-EFFECT TRANSISTOR AS A SOLID-STATE REFERENCE ELECTRODE
    COMTE, PA
    JANATA, J
    ANALYTICA CHIMICA ACTA, 1978, 101 (02) : 247 - 252
  • [4] RNA Detection Based on Graphene Field-Effect Transistor Biosensor
    Tian, Meng
    Xu, Shicai
    Zhang, Junye
    Wang, Xiaoxin
    Li, Zhenhua
    Liu, Huilan
    Song, Ruihong
    Yu, Ziheng
    Wang, Jihua
    ADVANCES IN CONDENSED MATTER PHYSICS, 2018, 2018
  • [5] ELECTROCHEMICAL REFERENCE ELECTRODE FOR THE ION-SELECTIVE FIELD-EFFECT TRANSISTOR
    TAHARA, S
    YOSHII, M
    OKA, S
    CHEMISTRY LETTERS, 1982, (03) : 307 - 310
  • [6] A Platinum Reference Electrode for Ion-Sensitive Field-Effect Transistor
    Zhao, Dan
    Zhang, Junkai
    Zhang, Jingwei
    Xu, Ming
    Wu, Dongping
    IEEE SENSORS JOURNAL, 2019, 19 (06) : 2003 - 2008
  • [7] Design Architecture of Field-effect Transistor with Back Gate Electrode for Biosensor Application
    Fathil, M. F. M.
    Arshad, M. K. Md
    Hashim, U.
    Ruslinda, A. R.
    Gopinath, Subash C. B.
    Nuzaihan, M. M. N.
    Ayub, R. M.
    Adzhri, R.
    Zaki, M.
    Azman, A. H.
    INTERNATIONAL CONFERENCE ON NANO-ELECTRONIC TECHNOLOGY DEVICES AND MATERIALS (IC-NET 2015), 2016, 1733
  • [8] Field-Effect Transistor with a Plasmonic Fiber Optic Gate Electrode as a Multivariable Biosensor Device
    Hasler, Roger
    Reiner-Rozman, Ciril
    Fossati, Stefan
    Aspermair, Patrik
    Dostalek, Jakub
    Lee, Seungho
    Ibanez, Maria
    Bintinger, Johannes
    Knoll, Wolfgang
    ACS SENSORS, 2022, 7 (02) : 504 - 512
  • [9] Performance Analysis of Feedback Field-Effect Transistor-Based Biosensor
    Singh, Deepika
    Patil, Ganesh C.
    IEEE SENSORS JOURNAL, 2020, 20 (22) : 13269 - 13276
  • [10] Field-Effect Transistor-Based Biosensor for pH Sensing and Mapping
    Ren, Huihui
    Liang, Kun
    Li, Dingwei
    Chen, Yitong
    Tang, Yingjie
    Wang, Yan
    Li, Fanfan
    Liu, Guolei
    Zhu, Bowen
    ADVANCED SENSOR RESEARCH, 2023, 2 (08):