摘要
The long-term performance of the bond between carbon fibre reinforced polymer composite (CFRP) fabrics and concrete substrate is crucial to estimations of the reliability of externally strengthened concrete structures. This paper presents the experimental results and analysis of 162 pull-off tests using nine concrete slabs under various environmental conditions, i.e., wet/dry cyclic exposure and full-immersion exposure of 3.5% salt-water at a temperature of 60 degrees C. The main objective of this study was to assess the effects on the bond performance of CFRP-strengthened concrete slabs during 12 months of exposure in a marine environment. Five types of failure modes were observed in the tested samples. The test results confirmed that 12 months of exposure in a marine environment had a low effect on the epoxy performance between CFRP and concrete. The results also indicated the marginal increase of pull-off strength values after 12 months of environmental exposure.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 16 条
  • [2] Experimental Study on Bond Strength of CFRP-concrete Interface in Sulfate Environment
    Liu S.
    Zhao J.
    Zhang J.
    Wang Z.
    Yang Z.
    Tiedao Xuebao/Journal of the China Railway Society, 2019, 41 (01): : 138 - 143
  • [3] Modifying CFRP-concrete bond characteristics from pull-out testing
    Haddad, Rami Haythem
    Al-Rousan, Rajai
    Ghanma, Lina
    Nimri, Zaid
    MAGAZINE OF CONCRETE RESEARCH, 2015, 67 (13) : 707 - 717
  • [4] Experimental and statistical dry-fracture assessment of the CFRP-concrete interface bond
    Boyajian, David
    Zirakian, Tadeh
    Boyajian, Christof
    Chen, Shen-En
    STRUCTURES, 2022, 36 : 580 - 588
  • [5] Bond characterization between concrete substrate and repairing SFRC using pull-off testing
    Bonaldo, E
    Barros, JAO
    Lourenço, PB
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2005, 25 (06) : 463 - 474
  • [6] Bond characterization between concrete substrate and repairing SFRC using pull-off testing
    Bonaldo, Everaldo
    Barros, Joaquim A.O.
    Lourenço, Paulo B.
    International Journal of Adhesion and Adhesives, 2005, 25 (06): : 463 - 474
  • [7] Prediction on compressive strength concrete using modified pull-off testing method (MPTM)
    Yang, Suhang
    Xu, Zhifeng
    Bian, Zhengning
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 250 (250)
  • [8] Effect of hot and humid acid rain environment on shear bond properties of CFRP-concrete interface
    Yi F.
    Yang J.
    Ma Z.
    Yin Y.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2023, 40 (08): : 4757 - 4767
  • [9] Evaluation of Pull-Off Tests as a FRP-Concrete Bond Testing Method in the Laboratory and Field
    Mate, Oscar R.
    Atadero, Rebecca A.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2014, 19 (02)
  • [10] Influence of substrate moisture state and roughness on interface microstructure and bond strength: Slant shear vs. pull-off testing
    Bentz, Dale P.
    De la Varga, Igor
    Munoz, Jose F.
    Spragg, Robert P.
    Graybeal, Benjamin A.
    Hussey, Daniel S.
    Jacobson, David L.
    Jones, Scott Z.
    LaManna, Jacob M.
    CEMENT & CONCRETE COMPOSITES, 2018, 87 : 63 - 72