On-line and real-time monitoring of organophilic pervaporation by mass spectrometry

被引:10
|
作者
Brazinha, Carla [1 ]
Fonseca, A. P. [2 ]
Teodoro, O. M. N. D. [2 ]
Crespo, Joao G. [1 ]
机构
[1] Univ Nova Lisboa, FCT, Dept Chem, REQUIMTE CQFB, P-2829516 Caparica, Portugal
[2] Univ Nova Lisboa, FCT, Dept Phys, CEFITEC, P-2829 Caparica, Portugal
关键词
Organophilic pervaporation; Fractionated condensation; Aroma/flavour recovery; Bioethanol; On-line mass spectrometry; Real-time monitoring; AROMA COMPOUNDS; SEPARATION; RECOVERY; MIXTURES; SORPTION;
D O I
10.1016/j.memsci.2009.10.009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This work demonstrates experimentally the use of mass spectrometry (MS) for on-line, quantitative monitoring of organophilic pervaporation processes operated not only under variable conditions of temperature of condensation/downstream pressure but also when using complex multi-component feed streams. Due to its high sensitivity, mass spectrometry is particularly suitable for on-line monitoring of aromas in dilute streams under reduced pressure, as happens with natural aromas in permeate streams. Mass spectrometry is also suitable for on-line monitoring of solvent and co-solvent permeants (water and ethanol in the selected case study), enabling for on-line determination of selectivity of the solutes of interest. A new method of calibration is proposed and validated, which correlates the intensity of the characteristic mass peak m(i)/z for each compound of interest with its partial pressure in the permeate stream. Moreover, mass spectrometry proves to be a powerful tool for studying the fractionation of aromas, recovered by integrated pervaporation-condensation processes, allowing on-line monitoring of each solute vapour in the permeate stream. Additionally, this technique enables for accurate transient studies due to the possibility of acquiring one data point every 12-15 s (potentially less, if desired) in real-time. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 92
页数:10
相关论文
共 50 条
  • [1] On-line mass spectrometry: Real-time monitoring and kinetics analysis for the photolysis of idoxifene
    Brum, J
    Dell'Orco, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (11) : 741 - 745
  • [2] Advanced oxidation of caffeine in water:: On-line and real-time monitoring by electrospray ionization mass spectrometry
    Dalmázio, I
    Santos, LS
    Lopes, RP
    Eberlin, MN
    Augusti, R
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (16) : 5982 - 5988
  • [3] Perspectives and limitations of using on-line mass spectrometry for monitoring of pervaporation processes
    Brazinha, Carla
    Crespo, Joao G.
    DESALINATION, 2006, 199 (1-3) : 334 - 336
  • [4] Supersonic jet spectrometry for on-line real-time monitoring of dioxins and their precursors
    Imasaka, T
    Matsumoto, J
    Uchimura, T
    Saito, G
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES II, 1999, 3853 : 34 - 41
  • [5] Process monitoring on-line & in real-time
    DePalma, Angelo
    GENETIC ENGINEERING NEWS, 2006, 26 (15): : 50 - 51
  • [6] Photocatalytic degradation of phenol and trichloroethylene: On-line and real-time monitoring via membrane introduction mass spectrometry
    Nogueira, RFP
    Alberici, RM
    Mendes, MA
    Jardim, WF
    Eberlin, MN
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (05) : 1754 - 1758
  • [7] Photocatalytic degradation of phenol and trichloroethylene: On-line and real-time monitoring via membrane introduction mass spectrometry
    Department of Civil Engineering, Institute of Chemistry, State University of Campinas-UNICAMP, 13083-970 Campinas, SP, Brazil
    Ind. Eng. Chem. Res., 5 (1754-1758):
  • [8] Real-time monitoring biomass pyrolysis via on-line photoionization ultrahigh-resolution mass spectrometry
    Zhou, Zhongyue
    Chen, Xiamin
    Ma, Hao
    Liu, Chunjiang
    Zhou, Chaoqun
    Qi, Fei
    FUEL, 2019, 235 : 962 - 971
  • [9] Real-time, on-line monitoring of organic chemical reactions using extractive electrospray ionization tandem mass spectrometry
    Zhu, Liang
    Gamez, Gerardo
    Chen, Huan Wen
    Huang, Hao Xi
    Chingin, Konstantin
    Zenobi, Renato
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (19) : 2993 - 2998
  • [10] Real-time on-line flow cytometry for bioprocess monitoring
    Broger, Tobias
    Odermatt, Res P.
    Huber, Pascal
    Sonnleitner, Bernhard
    JOURNAL OF BIOTECHNOLOGY, 2011, 154 (04) : 240 - 247