Test-retest reliability of two-dimensional video analysis during running

被引:52
|
作者
Dingenen, Bart [1 ]
Barton, Christian [2 ,3 ,4 ]
Janssen, Tessa [1 ]
Benoit, Anke [1 ]
Malliaras, Peter [3 ,5 ]
机构
[1] UHasselt, Fac Med & Life Sci, Biomed Res Inst, Rehabil Res Ctr, Diepenbeek, Belgium
[2] La Trobe Univ, Sch Allied Hlth, La Trobe Sport & Exercise Med Res Ctr, Bundoora, Vic, Australia
[3] Complete Sports Care, Hawthorn, Vic, Australia
[4] Univ Melbourne, St Vincents Hosp, Dept Surg, Melbourne, Vic, Australia
[5] Monash Univ, Fac Med Nursing & Hlth Sci, Sch Primary & Allied Hlth Care, Dept Physiotherapy, Clayton, Vic, Australia
关键词
Running; Kinematics; Two-dimensional video analysis; Reliability; PATELLOFEMORAL PAIN SYNDROME; ILIOTIBIAL BAND SYNDROME; TIBIAL STRESS-FRACTURE; STRENGTHENING PROGRAM; FEMALE RUNNERS; FOOT STRIKE; BIOMECHANICS; GAIT; HIP; INJURY;
D O I
10.1016/j.ptsp.2018.06.009
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To examine test-retest reliability of two-dimensional measured frontal and sagittal plane kinematics during running, and to determine how many steps to include to reach and maintain a stable mean. Design: Reliability study. Setting: Research laboratory. Participants: Twenty-one recreational runners. Main outcome measures: Lateral trunk position, contralateral pelvic drop, femoral adduction, hip adduction, knee flexion and ankle dorsiflexion during midstance, and foot and tibia inclination at initial contact were measured with two-dimensional video analysis during running for 10 consecutive steps for both legs. All participants were tested twice one week apart. A sequential estimation method was used to determine the number of steps needed to reach a stable mean. Intraclass correlation coefficients (ICC) and smallest detectable differences (SDD) were calculated. Results: The minimal number of steps was 6.3 +/- 0.3. Lateral trunk position, femoral adduction and foot inclination showed excellent reliability (ICC 0.90-0.99; SDD 1.3 degrees-2.3 degrees). Tibia inclination and ankle dorsiflexion showed good to excellent reliability (ICC 0.73-0.92; SDD 2.2 degrees-4.8 degrees). Hip adduction and knee flexion showed good reliability (ICC 0.82-0.89; SDD 2.3 degrees-3.8 degrees). Contralateral pelvic drop showed moderate to good reliability (ICC 0.59-0.77; SDD 2.7 degrees-2.8 degrees). Conclusion: Two-dimensional video analysis is reliable to assess running kinematics on different days. The mean of at least 7 steps should be included. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [1] The test-retest reliability of ride perception during treadmill and outdoor running
    Agresta, Cristine E.
    Peacock, Jillian
    Guadagnino, Sam
    Carmichael, Alicia
    Gonzalez, Richard
    FOOTWEAR SCIENCE, 2022, 14 (01) : 34 - 44
  • [2] Concurrent validity and test-retest reliability for the assessment of body segment lengths using two-dimensional video-recordings in weightlifting
    Lenz, Hannes
    Sandau, Ingo
    Witt, Maren
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2024, 12 (01):
  • [3] Cluster analysis for test-retest Reliability
    Roy, Debdulal Dutta
    INTERNATIONAL JOURNAL OF PSYCHOLOGICAL RESEARCH, 2010, 3 (01): : 131 - 139
  • [4] Test-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameters
    Jaen-Carrillo, Diego
    Ruiz-Alias, Santiago A.
    Chicano-Gutierrez, Jose M.
    Ruiz-Malagon, Emilio J.
    Roche-Seruendo, Luis E.
    Garcia-Pinillos, Felipe
    SENSORS, 2022, 22 (09)
  • [5] RELIABILITY OF TWO-DIMENSIONAL VIDEO-BASED RUNNING GAIT ANALYSIS
    Reinking, Mark F.
    Dugan, Leigh
    Ripple, Nolan
    Schleper, Karen
    Scholz, Henry
    Spadino, Jesse
    Stahl, Cameron
    McPoil, Thomas G.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2018, 13 (03): : 453 - 461
  • [6] Test-retest reliability of selected ground reaction force parameters and their symmetry during running
    Bennell, K
    Crossley, K
    Wrigley, T
    Nitschke, A
    JOURNAL OF APPLIED BIOMECHANICS, 1999, 15 (03) : 330 - 336
  • [7] Test-retest reliability of 3-dimensional computerized gait analysis
    Westhoff, B
    Hirsch, MA
    Hefter, H
    Wild, A
    Krauspe, R
    SPORTVERLETZUNG-SPORTSCHADEN, 2004, 18 (02) : 76 - 79
  • [8] Test-retest variability for quantitative two-dimensional and Doppler measurements in the fetus
    Allen, Catherine C.
    Keller, Regina
    Barnard, Krystle C.
    Gao, Zhiqian
    King, Eileen C.
    Michelfelder, Erik C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (01): : 142 - 149
  • [9] TEST-RETEST RELIABILITY OF ACTIVITY VECTOR ANALYSIS
    MERENDA, PF
    CLARKE, WV
    PSYCHOLOGICAL REPORTS, 1959, 5 (01) : 27 - 30
  • [10] Test-Retest Reliability and Construct Validity of the Standardized Video Interview
    Jayakumar, Kishore L.
    ACADEMIC MEDICINE, 2018, 93 (11) : 1599 - 1599