Nonlinear Variable Resistor-Based FCL for Fault Ride-Through Performance Enhancement of DFIG-Based Wind Turbines

被引:0
|
作者
Firouzi, Mehdi [1 ]
Shafiee, Mohammadreza [2 ]
Nasiri, Mojtaba [3 ]
机构
[1] Islamic Azad Univ, Abhar Branch, Dept Elect Engn, Abhar, Iran
[2] Univ Semnan, Dept Elect & Comp Engn, Semnan, Iran
[3] Trinity Coll Dublin, Sch Engn, Solar Energy Applicat Grp, Dublin 2, Ireland
关键词
CURRENT LIMITER; STABILITY ENHANCEMENT; TRANSIENT STABILITY; IMPROVEMENT; CAPABILITY; GENERATOR; SCHEMES; FARMS;
D O I
10.1155/2021/9934887
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fault ride-through (FRT) requirement is a matter of great concern for doubly fed induction generator (DFIG-) based wind turbines (WTs). This study presents a nonlinear variable resistor- (NVR-) based bridge-type fault current limiter (BFCL) to augment the FRT performance of DFIG-based WTs. First, the BFCL operation and nonlinear control design consideration of the proposed NVR-based BFCL are presented. Then, the NVR-BFCL performance is validated through simulation in PSCAD/EMTDC software. In addition, the NVR-based BFCL performance is compared with the fixed resistor- (FR-) based BFCL for a three-phase symmetrical short circuit fault at the grid side. Simulation results reveal that the NVR-based BFCL provides a smooth and effective FRT scheme and outperforms the FR-based BFCL.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines
    Dang, Hoang P.
    Pico, Hugo Villegas N.
    IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (03) : 2060 - 2074
  • [2] Sliding Mode Controller-Based BFCL for Fault Ride-Through Performance Enhancement of DFIG-Based Wind Turbines
    Firouzi, Mehdi
    Nasiri, Mojtaba
    Mobayen, Saleh
    Gharehpetian, G. B.
    COMPLEXITY, 2020, 2020 (2020)
  • [3] Modeling of complete fault ride-through processes for DFIG-Based wind turbines
    Li, Weixing
    Chao, Pupu
    Liang, Xiaodong
    Sun, Yong
    Qi, Jinling
    Chang, Xuefei
    RENEWABLE ENERGY, 2018, 118 : 1001 - 1014
  • [4] High Voltage Ride-Through of DFIG-based Wind Turbines
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Koch, F.
    Erlich, I.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1477 - 1484
  • [5] Study of fault ride-through for DFIG based wind turbines
    Bing, X
    Fox, B
    Flynn, D
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 411 - 416
  • [6] A new hybrid multilevel converter for DFIG-based wind turbines fault ride-through and transient stability enhancement
    Arthur E. A. Amorim
    Daniel Carletti
    Jussara F. Fardin
    Lucas F. Encarnação
    Domingos S. L. Simonetti
    Electrical Engineering, 2020, 102 : 1035 - 1050
  • [7] A new hybrid multilevel converter for DFIG-based wind turbines fault ride-through and transient stability enhancement
    Amorim, Arthur E. A.
    Carletti, Daniel
    Fardin, Jussara F.
    Encarnacao, Lucas F.
    Simonetti, Domingos S. L.
    ELECTRICAL ENGINEERING, 2020, 102 (02) : 1035 - 1050
  • [8] Fault-Ride Through Capability Enhancement of DFIG-Based Wind Turbines by SFCL
    Abdellatif, Walid S. E.
    Alaboudy, Ali H. Kasem
    Azmy, Ahmed M.
    2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 1104 - 1109
  • [9] Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm
    M. Kenan Döşoğlu
    Nonlinear Dynamics, 2017, 89 : 2683 - 2694
  • [10] Improving the Fault Ride-through Capability of DFIG-Based Wind Turbines Using the Dynamic Impedance
    Liang, Yabo
    Cao, Yunzhu
    Li, Lei
    Sheng, Yaru
    Niu, Jian
    He, Jianan
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1185 - 1189