MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers

被引:50
|
作者
Wehner, J. [1 ]
Weissler, B. [2 ,3 ]
Dueppenbecker, P. M. [1 ,4 ]
Gebhardt, P. [4 ]
Goldschmidt, B. [1 ]
Schug, D. [1 ]
Kiessling, F. [5 ]
Schulz, V. [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Dept Phys Mol Imaging Syst, Inst Expt Mol Imaging Syst, D-52074 Aachen, Germany
[2] Philips Res Europe, Aachen, Germany
[3] Rhein Westfal TH Aachen, Inst Hochfrequenztech, D-52062 Aachen, Germany
[4] Kings Coll London, London WC2R 2LS, England
[5] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, D-52062 Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 06期
基金
英国惠康基金;
关键词
PET; MRI; silicon photo multiplier; multimodality imaging; instrumentation; INTERFERENCE; DETECTOR; SCANNER;
D O I
10.1088/0031-9155/60/6/2231
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PET (positron emission tomography) with its high sensitivity in combination with MRI (magnetic resonance imaging) providing anatomic information with good soft-tissue contrast is considered to be a promising hybrid imaging modality. However, the integration of a PET detector into an MRI system is a challenging task since the MRI system is a sensitive device for external disturbances and provides a harsh environment for electronic devices. Consequently, the PET detector has to be transparent for the MRI system and insensitive to electromagnetic disturbances. Due to the variety of MRI protocols imposing a wide range of requirements regarding the MR-compatibility, an extensive study is mandatory to reliably assess worst-case interference phenomena between the PET detector and the MRI scanner. We have built the first preclinical PET insert, designed for a clinical 3 T MRI, using digital silicon photomultipliers (digital SiPM, type DPC 3200-22, Philips Digital Photon Counting). Since no thorough interference investigation with this new digital sensor has been reported so far, we present in this work such a comprehensive MR-compatibility study. Acceptable distortion of the B-0 field homogeneity (volume RMS = 0.08 ppm, peak-to-peak value = 0.71 ppm) has been found for the PET detector installed. The signal-to-noise ratio degradation stays between 2-15% for activities up to 21 MBq. Ghosting artifacts were only found for demanding EPI (echo planar imaging) sequences with read-out gradients in Z direction caused by additional eddy currents originated from the PET detector. On the PET side, interference mainly between the gradient system and the PET detector occurred: extreme gradient tests were executed using synthetic sequences with triangular pulse shape and maximum slew rate. Under this condition, a relative degradation of the energy (<= 10%) and timing (<= 15%) resolution was noticed. However, barely measurable performance deterioration occurred when morphological MRI protocols are conducted certifying that the overall PET performance parameters remain unharmed.
引用
收藏
页码:2231 / 2255
页数:25
相关论文
共 20 条
  • [1] MR-compatibility study of a preclinical digital PET/MRI insert
    Jakob Wehner
    Björn Weissler
    Peter Dueppenbecker
    Pierre Gebhardt
    Benjamin Goldschmidt
    Christoph Lerche
    Andre Salomon
    David Schug
    Volkmar Schulz
    EJNMMI Physics, 1 (Suppl 1)
  • [2] MR-compatibility study of a preclinical digital PET/MRI insert Abstracts
    不详
    EJNMMI PHYSICS, 2014, 1
  • [3] PET/MRI insert using digital SiPMs: Investigation of MR-compatibility
    Wehner, Jakob
    Weissler, Bjoern
    Dueppenbecker, Peter
    Gebhardt, Pierre
    Schug, David
    Ruetten, Walter
    Kiessling, Fabian
    Schulz, Volkmar
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 116 - 121
  • [4] Evaluation of PET performance and MR compatibility of a preclinical PET/MR insert with digital silicon photomultiplier technology
    Patrick Hallen
    David Schug
    Jakob Wehner
    Bjorn Weissler
    Pierre Gebhardt
    Benjamin Goldschmidt
    Andre Salomon
    Peter Duppenbecker
    Fabian Kiessling
    Volkmar Schultz
    EJNMMI Physics, 2 (Suppl 1)
  • [5] MR-compatibility of a high-resolution small animal PET insert operating inside a 7 T MRI
    Thiessen, J. D.
    Shams, E.
    Stortz, G.
    Schellenberg, G.
    Bishop, D.
    Khan, M. S.
    Kozlowski, P.
    Retiere, F.
    Sossi, V.
    Thompson, C. J.
    Goertzen, A. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22): : 7934 - 7956
  • [6] PET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators
    Schug, David
    Wehner, Jakob
    Dueppenbecker, Peter Michael
    Weissler, Bjoern
    Gebhardt, Pierre
    Goldschmidt, Benjamin
    Salomon, Andre
    Kiessling, Fabian
    Schulz, Volkmar
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (18): : 7045 - 7067
  • [7] Assessment of MR-compatibility of SiPM PET insert using short optical fiber bundles for small animal research
    Kang, H. G.
    Hong, S. J.
    Ko, G. B.
    Yoon, H. S.
    Song, I. C.
    Rhee, J. T.
    Lee, J. S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [8] MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system
    Omidvari, Negar
    Topping, Geoffrey
    Cabello, Jorge
    Paul, Stephan
    Schwaiger, Markus
    Ziegler, Sibylle, I
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09):
  • [9] Design concept of world's first preclinical PET/MR insert with fully digital silicon photomultiplier technology
    Weissler, Bjoern
    Gebhardt, Pierre
    Dueppenbecker, Peter
    Goldschmidt, Benj Amin
    Salomon, Andre
    Schug, David
    Wehner, Jakob
    Lerche, Christoph
    Wirtz, Daniel
    Renz, Wolfgang
    Schumacher, Katharina
    Zwaans, Ben
    Marsden, Paul
    Kiessling, Fabian
    Schulz, Volkmar
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2113 - 2116
  • [10] PET performance evaluation of a preclinical digital PET/MRI insert
    David Schug
    Christoph Lerche
    Peter Dueppenbecker
    Pierre Gebhardt
    Benjamin Goldschmidt
    Andre Salomon
    Jakob Wehner
    Bjoern Weissler
    Fabian Kiessling
    Volkmar Schulz
    EJNMMI Physics, 1 (Suppl 1)