DFIG-based Wind Energy Conversion Systems Under Unbalanced Voltage Dips

被引:0
|
作者
Tourou, Pavlos [1 ]
Sourkounis, Constantinos [1 ]
机构
[1] Ruhr Univ Bochum, Fac Elect Engn & Informat Technol, Inst Power Syst Technol & Power Mechatron, D-44801 Bochum, Germany
关键词
wind energy; doubly-fed induction generator; DFIG; unbalanced faults; low voltage ride-through; reactive power; wind power integration; negative sequence control; FED INDUCTION GENERATOR; CONVERTERS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the uptake of wind power increasing steadily on a global level, the grid compatibility of wind energy conversion systems (WECS) must be improved to ensure that electrical networks with a high wind penetration remain stable and reliable. For this reason WECS must now be able to remain connected to the grid during balanced and unbalanced grid faults and to provide ancillary services such as reactive power support to the grid as stipulated by the grid code requirements. Unbalanced grid voltages can have significant negative effects on the performance of wind energy conversion systems equipped with doubly-fed induction generators. These effects can decrease the lifetime of the system and in extreme cases they can lead to violation of the grid code requirements. In this paper a control strategy is presented, which minimizes torque oscillations and total active power oscillations in the DFIG that arise due to unbalanced voltage conditions in the grid.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 50 条
  • [1] Control and Protection of a DFIG-Based Wind Turbine under Unbalanced Grid Voltage Dips
    Zhou, Peng
    He, Yikang
    Sun, Dan
    Zhu, Jianguo
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 2375 - +
  • [2] Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
    Rahimi, Mohsen
    Parniani, Mostafa
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 60 : 82 - 95
  • [3] Evaluation of the Control Limit of Rotor-Side Converters in DFIG-based Wind Energy Conversion Systems under Symmetrical Voltage Dips
    Zhou, Honglin
    Yang, Geng
    Geng, Hua
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [4] A novel control scheme for DFIG-based wind energy systems under unbalanced grid conditions
    Fan, Lingling
    Yin, Haiping
    Miao, Zhixin
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (02) : 254 - 262
  • [5] A DFIG-based Wind Turbine Operation under Balanced and Unbalanced Grid Voltage Conditions
    Boukili, Yassine
    Aguiar, A. Pedro
    Carvalho, Adriano
    IFAC PAPERSONLINE, 2020, 53 (02): : 12835 - 12840
  • [6] Control of DFIG-Based wind generation systems under unbalanced network supply
    Wang, Yi
    Xu, Lie
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 430 - +
  • [7] Negative Sequence Compensation Techniques of DFIG-based Wind Energy Systems under Unbalanced Grid Conditions
    Fan, Lingling
    Yin, Haiping
    Kavasseri, Rajesh
    2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 83 - 88
  • [8] Thermal Analysis of Power Converters for DFIG-Based Wind Energy Conversion Systems during Voltage Sags
    de Oliveira, Igor Rodrigues
    Tofoli, Fernando Lessa
    Mendes, Victor Flores
    ENERGIES, 2022, 15 (09)
  • [9] Control ofa DFIG-based wind turbine under unbalanced grid voltage dips based on anew method to separate positive and negative sequence components
    Wang, Yun
    Cao, Guangzhong
    Wang, Yun, 1607, Science Press (35): : 1607 - 1613
  • [10] A control strategy for DFIG-based systems operating under unbalanced grid voltage conditions
    Gonzalez, Guillermo N.
    Angelo, Cristian H. De
    Aligia, Diego A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 142