Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: A planning comparison

被引:30
|
作者
Broggi, Sara [1 ]
Perna, Lucia [1 ]
Bonsignore, Francesco [2 ]
Rinaldin, Giuseppe [1 ]
Fiorino, Claudio [1 ]
Chiara, Anna [3 ]
Frigerio, Cristina [2 ]
Butti, Ivana [2 ]
Sangalli, Giulia [2 ]
Dell'Oca, Italo [3 ]
Di Muzio, Nadia [3 ]
Cattaneo, Giovanni Mauro [1 ]
Declich, Fausto [2 ]
机构
[1] Ist Sci San Raffaele, Dept Med Phys, I-20132 Milan, Italy
[2] Osped A Manzoni, Dept Med Phys, Lecce, Italy
[3] Ist Sci San Raffaele, Dept Radiotherapy, I-20132 Milan, Italy
来源
关键词
Head and neck cancer; Volumetric arc techniques; IMRT; Dosimetrical comparison; OROPHARYNGEAL CANCER; HELICAL TOMOTHERAPY; ARC THERAPY; IMRT; CARCINOMA; SMARTARC; SHOOT; STEP;
D O I
10.1016/j.ejmp.2014.07.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare helical Tomotherapy (HT), two volumetric-modulated arc techniques and conventional fixed-field intensity modulated techniques (S-IMRT) for head-neck (HN) cancers. Methods and materials: Eighteen HN patients were considered. Four treatment plans were generated for each patient: HT, S-IMRT optimised with Eclipse treatment planning system and two volumetric techniques using Elekta-Oncentra approach (VMAT) and Varian-RapidArc (RA), using two full arcs. All techniques were optimised to simultaneously deliver 66Gy to PTV1 (GTV and enlarged nodes) and 54Gy to PTV2 (subclinical and electively treated nodes). Comparisons were assessed on several dosimetric parameters and, secondarily, on planned MUs and delivery time. Results: Concerning PTV coverage, significantly better results were found for HT and RA. HT significantly improved the target coverage both compared to S-IMRT and VMAT. No significant differences were found between S-IMRT and volumetric techniques in terms of dose homogeneity. For OARs, all the techniques were able to satisfy all hard constraints; significantly better results were found for HT, especially in the intermediate dose range (15-30 Gy). S-IMRT reached a significantly better OARs sparing with respect to VMAT and RA. No significant differences were found for body mean dose, excepting higher values of V5 -V10 for HT. A reduction of planned MUs and delivery treatment time was found with volumetric techniques. Conclusions: The objectives of satisfying target coverage and sparing of critical structures were reached with all techniques. S-IMRT techniques were found more advantageous compared to RA and VMAT for OARs sparing. HT reached the best overall treatment plan quality. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:973 / 979
页数:7
相关论文
共 50 条
  • [1] A Planning Comparison between RapidArc and Intensity Modulated Radiotherapy for Head and Neck cancer
    Jiang, R.
    Fleck, A.
    Schaly, B.
    Charland, P.
    Zhan, L.
    Alliet, K.
    Rachakonda, R.
    Osei, E.
    MEDICAL PHYSICS, 2012, 39 (07) : 4637 - 4637
  • [2] Volumetric Modulated Arc Therapy for Head and Neck Cancer: A Dosimetric and Treatment Planning Comparison with Intensity Modulated Radiotherapy Techniques
    Goswami, Brijesh
    Yadav, Suresh
    Jain, Rakesh Kumar
    Goswami, Pradeep
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (03)
  • [3] A comparison of forward and inverse treatment planning for intensity-modulated radiotherapy of head and neck cancer
    Bär, W
    Schwarz, M
    Alber, M
    Bos, LJ
    Mijnheer, BJ
    Rasch, C
    Schneider, C
    Nüsslin, F
    Damen, EMF
    RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) : 251 - 258
  • [4] Radiotherapy of prostate and head-and-neck tumour: An optimal treatment planning comparison for intensity modulated radiotherapy and volumetric modulated arctherapy techniques
    Murtaza, Ghulam
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2024, 74 (01) : 16 - 20
  • [5] Skin dose: Comparison of intensity modulated radiotherapy and three field conformal techniques for head and neck cancer
    Noh, E.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S475 - S476
  • [6] Re-planning of intensity modulated radiotherapy (IMRT) for head and neck cancer patients
    Dogan, N.
    Cuttino, L.
    Shumadine, J.
    Song, S.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S229 - S229
  • [7] The role of intensity-modulated radiotherapy in head and neck cancer
    Bhide, S. A.
    Kazi, R.
    Newbold, K.
    Harrington, K. J.
    Nutting, C. M.
    INDIAN JOURNAL OF CANCER, 2010, 47 (03) : 267 - 273
  • [8] INTENSITY MODULATED RADIOTHERAPY (IMRT) IN PATIENTS WITH HEAD AND NECK CANCER
    Van den Weyngaert, D.
    Van Gestel, D.
    Dom, B.
    Schrijvers, D.
    Vermorken, J. B.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S258 - S258
  • [9] A comparison of photon and proton radiotherapy treatment planning techniques in head and neck cancer
    Church, D.
    Paterson, C.
    Currie, S.
    Houston, P.
    Valentine, R.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S809 - S810
  • [10] Target coverage in head and neck cancer treated with intensity-modulated radiotherapy: A comparison between conventional and conformal techniques
    Palazzi, Mauro
    Orlandi, Ester
    Pignoli, Emanuele
    Lualdi, Manuela
    Zonca, Giancarlo
    Sangalli, Claudia
    Stucchi, Claudio
    Olmi, Patrizia
    TUMORI JOURNAL, 2006, 92 (06): : 503 - 510