Micro-Electro-Mechanical Systems/Near-Infrared Validation of Different Sampling Modes and Sample Sets Coupled with Multiple Models

被引:2
|
作者
Wu, Zhisheng [1 ,2 ,3 ]
Shi, Xinyuan [1 ,2 ,3 ]
Wan, Guang [1 ]
Xu, Manfei [1 ]
Zhan, Xueyan [1 ]
Qiao, Yanjiang [1 ,2 ,3 ]
机构
[1] Beijing Univ Chinese Med, Sch Chinese Pharm, Beijing 100102, Peoples R China
[2] TCM, TCM informat Engn State Adm, Key Lab, Beijing, Peoples R China
[3] Beijing Key Lab Basic & Dev Res Chinese Med, Beijing, Peoples R China
关键词
near-infrared; accuracy profile; integrating sphere; process analytical technology; fiber optic sensor; ETHANOL PRECIPITATION PROCESS; LONICERA-JAPONICA SOLUTION; CHLOROGENIC ACID; QUALITY-CONTROL; NIR MODEL; SPECTROSCOPY; EXTRACTION; QUANTIFICATION; DISCRIMINATION; CHEMOMETRICS;
D O I
10.1055/s-0034-1396152
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
The aim of the present study was to demonstrate the reliability of micro-electro-mechanical systems/near-infrared technology by investigating analytical models of two modes of sampling (integrating sphere and fiber optic probe modes) and different sample sets. Baicalin in Yinhuang tablets was used as an example, and the experimental procedure included the optimization of spectral pretreatments, selection of wavelength regions using interval partial least squares, moving window partial least squares, and validation of the method using an accuracy profile. The results demonstrated that models that use the integrating sphere mode are better than those that use fiber optic probe modes. Spectra that use fiber optic probe modes tend to be more susceptible to interference information because the intensity of the incident light on a fiber optic probe mode is significantly weaker than that on an integrating sphere mode. According to the test set validation result of the method parameters, such as accuracy, precision, risk, and linearity, the selection of variables was found to make no significant difference to the performance of the full spectral model. The performance of the models whose sample sets ranged widely in concentration (i.e., 1-4%) was found to be better than that of models whose samples had relatively narrow ranges (i.e., 1-2%). The establishment and validation of this method can be used to clarify the analytical guideline in Chinese herbal medicine about two sampling modes and different sample sets in the micro-electro-mechanical systems/near-infrared technique.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 19 条
  • [1] Applying Kirigami Models in Teaching Micro-electro-mechanical Systems
    Liang, Yung C.
    PROCEEDINGS OF THE 2013 THIRD INTERDISCIPLINARY ENGINEERING DESIGN EDUCATION CONFERENCE (IEDEC 2013), 2013, : 83 - 86
  • [2] Noise reduction and estimation in multiple micro-electro-mechanical inertial systems
    Waegli, Adrian
    Skaloud, Jan
    Guerrier, Stephane
    Eulalia Pares, Maria
    Colomina, Ismael
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (06)
  • [3] Arthropod motion-sensing hairs: Biological models for micro-electro-mechanical systems
    Humphrey, Joseph A.C.
    Barth, Friedrich G.
    American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD, 2000, 366 : 115 - 120
  • [4] Improved simulation for strongly coupled micro-electro-mechanical systems: resonant vacuum sensor optimization
    Folkmer, B.
    Siber, A.
    Bley, W. Großse
    Sandmaier, H.
    Lang, W.
    Sensors and Actuators, A: Physical, 1999, 74 (01): : 190 - 192
  • [5] Comparison of generalized differential quadrature and Galerkin methods for the analysis of micro-electro-mechanical coupled systems
    Sadeghian, Hamed
    Rezazadeh, Ghader
    COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2009, 14 (06) : 2807 - 2816
  • [6] Improved simulation for strongly coupled micro-electro-mechanical systems: resonant vacuum sensor optimization
    Folkmer, B
    Siber, A
    Bley, WG
    Sandmaier, H
    Lang, W
    SENSORS AND ACTUATORS A-PHYSICAL, 1999, 74 (1-3) : 190 - 192
  • [7] Review and comparison of different support loss models for micro-electro-mechanical systems resonators undergoing in-plane vibration
    Chouvion, B.
    McWilliam, S.
    Popov, A. A.
    Fox, C. H. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2012, 226 (C1) : 283 - 295
  • [8] Design of a micro-opto-electro-mechanical-system-based near-infrared hyperspectral imager
    Egloff, Thomas
    Knobbe, Jens
    Sinzinger, Stefan
    Grueger, Heinrich
    APPLIED OPTICS, 2009, 48 (34) : 6583 - 6593
  • [9] Three-dimensional profile measurement of micro-electro-mechanical systems structures based on infrared light reflection interference
    Shi, Jianhua
    Han, Bingchen
    LASER PHYSICS, 2017, 27 (11)
  • [10] Hitless Wavelength Selective Switch Using Vertically Coupled Microring Resonator Manipulated by Micro-Electro-Mechanical Systems Structure
    Yamada, Takuma
    Kokubun, Yasuo
    APPLIED PHYSICS EXPRESS, 2009, 2 (06)