A mathematical method for quantifying in vivo mechanical behaviour of heel pad under dynamic load

被引:17
|
作者
Naemi, Roozbeh [1 ]
Chatzistergos, Panagiotis E. [1 ]
Chockalingam, Nachiappan [1 ]
机构
[1] Staffordshire Univ, Fac Hlth Sci, Stoke On Trent ST4 2DE, Staffs, England
关键词
Biomechanics; Plantar soft tissue; Ultrasound indentation; Viscoelastic; Stress-strain model; STANCE PHASE; FAT PAD; FOOT; TISSUE; MODEL; SIMULATION; IMPACT;
D O I
10.1007/s11517-015-1316-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical behaviour of the heel pad, as a shock attenuating interface during a foot strike, determines the loading on the musculoskeletal system during walking. The mathematical models that describe the force deformation relationship of the heel pad structure can determine the mechanical behaviour of heel pad under load. Hence, the purpose of this study was to propose a method of quantifying the heel pad stress-strain relationship using force-deformation data from an indentation test. The energy input and energy returned densities were calculated by numerically integrating the area below the stress-strain curve during loading and unloading, respectively. Elastic energy and energy absorbed densities were calculated as the sum of and the difference between energy input and energy returned densities, respectively. By fitting the energy function, derived from a nonlinear viscoelastic model, to the energy density-strain data, the elastic and viscous model parameters were quantified. The viscous and elastic exponent model parameters were significantly correlated with maximum strain, indicating the need to perform indentation tests at realistic maximum strains relevant to walking. The proposed method showed to be able to differentiate between the elastic and viscous components of the heel pad response to loading and to allow quantifying the corresponding stress-strain model parameters.
引用
收藏
页码:341 / 350
页数:10
相关论文
共 50 条
  • [1] A mathematical method for quantifying in vivo mechanical behaviour of heel pad under dynamic load
    Roozbeh Naemi
    Panagiotis E. Chatzistergos
    Nachiappan Chockalingam
    Medical & Biological Engineering & Computing, 2016, 54 : 341 - 350
  • [2] IN-VIVO EXAMINATION OF THE DYNAMIC PROPERTIES OF THE HUMAN HEEL PAD
    KINOSHITA, H
    OGAWA, T
    KUZUHARA, K
    IKUTA, K
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (06) : 312 - 319
  • [3] Investigations on the viscoelastic behaviour of a human healthy heel pad: In vivo compression tests and numerical analysis
    Matteoli, Sara
    Fontanella, Chiara G.
    Carniel, Emanuele L.
    Wilhjelm, Jens E.
    Virga, Antonio
    Corbin, Nadege
    Corvi, Andrea
    Natali, Arturo N.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H3) : 334 - 342
  • [4] Dynamic material characterization of the human heel pad based on in vivo experimental tests and numerical analysis
    Kardeh, M.
    Vogl, T. J.
    Huebner, F.
    Nelson, K.
    Stief, F.
    Silber, G.
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) : 940 - 945
  • [5] THE MECHANICAL CHARACTERISTICS OF THE HUMAN HEEL PAD DURING FOOT STRIKE IN RUNNING - AN IN-VIVO CINERADIOGRAPHIC STUDY
    DECLERCQ, D
    AERTS, P
    KUNNEN, M
    JOURNAL OF BIOMECHANICS, 1994, 27 (10) : 1213 - &
  • [6] Shear wave elastography can assess the in-vivo nonlinear mechanical behavior of heel-pad
    Chatzistergos, Panagiotis E.
    Behforootan, Sara
    Allan, David
    Naemi, Roozbeh
    Chockalingam, Nachiappan
    JOURNAL OF BIOMECHANICS, 2018, 80 : 144 - 150
  • [7] Influence of age, gender, and obesity on the mechanical properties of the heel pad under walking impact conditions
    Alcántara, Enrique
    Forner, Arturo
    Ferrús, Elena
    García, Ana-Cruz
    Ramiro, José
    1600, Human Kinetics Publishers Inc. (18):
  • [8] Influence of age, gender, and obesity on the mechanical properties of the heel pad under walking impact conditions
    Alcántara, E
    Forner, A
    Ferrús, E
    García, AC
    Ramiro, J
    JOURNAL OF APPLIED BIOMECHANICS, 2002, 18 (04) : 345 - 356
  • [9] The behaviour of DLC under high mechanical and thermal load
    Reisel, G
    Steinhäuser, S
    Wielage, B
    DIAMOND AND RELATED MATERIALS, 2004, 13 (4-8) : 1516 - 1520
  • [10] Investigation on the load-displacement curves of a human healthy heel pad: In vivo compression data compared to numerical results
    Fontanella, C. G.
    Matteoli, S.
    Carniel, E. L.
    Wilhjelm, J. E.
    Virga, A.
    Corvi, A.
    Natali, A. N.
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (09) : 1253 - 1259