Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT

被引:15
|
作者
Abbene, Leonardo [1 ]
Principato, Fabio [1 ]
Buttacavoli, Antonino [1 ]
Gerardi, Gaetano [1 ]
Bettelli, Manuele [2 ]
Zappettini, Andrea [2 ]
Altieri, Saverio [3 ,4 ]
Auricchio, Natalia [5 ]
Caroli, Ezio [5 ]
Zanettini, Silvia [6 ]
Protti, Nicoletta [3 ,4 ]
机构
[1] Univ Palermo, Dept Phys & Chem DiFC Emilio Segre, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[2] CNR, IMEM, Parco Area Sci 37-A, I-43100 Parma, Italy
[3] Univ Pavia, Dept Phys, Via Agostino Bassi 6, I-27100 Pavia, Italy
[4] Nucl Phys Natl Inst INFN, Unit Pavia, Via Agostino Bassi 6, I-27100 Pavia, Italy
[5] OAS Bologna, INAF, I-40129 Bologna, Italy
[6] Due2lab srl, Via Paolo Borsellino 2, I-42019 Scandiano, Italy
关键词
CZT detectors; X-ray and gamma-ray detectors; BNCT; NEUTRON-CAPTURE THERAPY; THICK CDTE DETECTOR; COMPTON CAMERA; PG-SPECT; SYSTEM; ARRAYS;
D O I
10.3390/s22041502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, new high-resolution cadmium-zinc-telluride (CZT) drift strip detectors for room temperature gamma-ray spectroscopic imaging were developed by our group. The CZT detectors equipped with orthogonal anode/cathode collecting strips, drift strips and dedicated pulse processing allow a detection area of 6 x 20 mm(2) and excellent room temperature spectroscopic performance (0.82% FWHM at 661.7 keV). In this work, we investigated the potentialities of these detectors for prompt gamma-ray spectroscopy (PGS) in boron neutron capture therapy (BNCT). The detectors, exploiting the measurement of the 478 keV prompt gamma rays emitted by 94% Li-7 nuclides from the B-10(n, alpha)Li-7 reaction, are very appealing for the development of single-photon emission computed tomography (SPECT) systems and Compton cameras in BNCT. High-resolution gamma-ray spectra from B-10 samples under thermal neutrons were measured at the T.R.I.G.A. Mark II research nuclear reactor of the University of Pavia (Italy).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] CZT detectors with 3-D readout for gamma-ray spectroscopy and imaging
    Matteson, JL
    Pelling, MR
    Skelton, RT
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 1 - 13
  • [2] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C.
    Longoni, A.
    Perotti, F.
    Labanti, C.
    Rossi, E.
    Lechner, P.
    Soltau, H.
    Strüder, Lothar
    IEEE Transactions on Nuclear Science, 2002, 49 II (03) : 995 - 1000
  • [3] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 25 - 28
  • [4] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 995 - 1000
  • [5] The development of coplanar CZT strip detectors for gamma-ray astronomy
    McConnell, ML
    Hamel, LA
    Macri, JR
    McClish, M
    Ryan, JM
    GAMMA 2001, 2001, 587 : 909 - 913
  • [6] Use of CZT as 3D Detectors for Gamma-Ray Astronomy
    Quadrini, E.
    Alderighi, M.
    Uslenghi, M.
    Auricchio, N.
    Caroli, E.
    Schiavone, F.
    Donati, A.
    Natalucci, L.
    Ubertini, P.
    Del Sordo, S.
    Casini, F.
    Bastia, P.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4973 - +
  • [7] Evaluation of CZT Drift Strip Detectors for Use in 3-D Molecular Breast Imaging
    Owe, S. R. H.
    Kuvvetli, I.
    Cherlin, A.
    Harris, B.
    Tomita, H.
    Baistow, I.
    Tcherniak, D.
    Budtz-Jorgensen, C.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (02) : 113 - 123
  • [8] Spatial variation of energy resolution in 3-D position sensitive CZT gamma-ray spectrometers
    Univ of Michigan, Ann Arbor, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (628-633):
  • [9] Spatial variation of energy resolution in 3-D position sensitive CZT gamma-ray spectrometers
    Li, W
    He, Z
    Knoll, GF
    Wehe, DK
    Stahle, CM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 187 - 192
  • [10] High-resolution gamma-ray spectroscopy of hypernuclei with germanium detectors
    Tanida, K
    Tamura, H
    Abe, D
    Ajimura, S
    Akikawa, P
    Araki, K
    Bhang, HC
    Chrien, RE
    Eugenio, P
    Frankling, GB
    Fujii, Y
    Fukuda, T
    Gan, L
    Hashimoto, O
    Hotchi, H
    Imai, K
    Kakiguchi, Y
    Khaustov, P
    Kim, JH
    Kim, YD
    Kohri, H
    May, M
    Miyoshi, T
    Murakami, T
    Nagae, T
    Nakano, J
    Noumi, H
    Ozawa, K
    Outa, H
    Pile, PH
    Quinn, BP
    Rusek, A
    Saito, T
    Sasao, J
    Sato, Y
    Satoh, S
    Sawafta, RI
    Schumacher, RA
    Sekimoto, M
    Takahashi, T
    Tamagawa, T
    Tang, L
    Xia, HH
    Yuan, L
    Zhou, SH
    Zhou, LH
    Zhu, XF
    NUCLEAR PHYSICS A, 2001, 684 : 560C - 562C