Evaluation of Dentin Tubule Plugging Efficiencies and Effects on Dentin Surface Roughness of Dentin Desensitizing Agents, the Er,Cr:YSGG Laser, and Their Combination After Erosion-abrasion Cycles: An In Vitro Study

被引:2
|
作者
Okur, E. [1 ]
Eyuboglu, G. B. [1 ]
机构
[1] Karadeniz Tech Univ, Sch Dent, Dept Restorat Dent, Ortahisar Trabzon, Turkey
关键词
SODIUM-FLUORIDE VARNISH; BACTERIAL PLAQUE RETENTION; ORAL HARD MATERIALS; CLINICAL-EVALUATION; BOND STRENGTH; HUMAN ENAMEL; YAG LASER; ND-YAG; HYPERSENSITIVITY; IRRADIATION;
D O I
10.2341/21-086-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purposes of this in vitro study were to evaluate the tubule plugging efficiencies and effects on the surface roughness of dentin of different dentin desensitizing agents (DDAs; Teethmate Desensitizer, Kuraray; Gluma Desensitizer, Kulzer; Clinpro White Varnish, 3M ESPE; Enamelast, Ultradent) and the Er,Cr:YSGG laser (Biolase, Waterlase), both alone and in combination with DDAs, after application and after an erosion-abrasion cycle. Methods and Materials: For surface roughness examinations, superficial buccal dentin specimens were divided into 10 groups: the control, Teethmate Desensitizer, Gluma Desensitizer, Enamelast, Clipro White Varnish, Er,Cr:YSGG Laser, Teethmate Desensitizer-Laser, Gluma Desensitizer-Laser, and Enamelast-Laser, and Clinpro White Varnish-Laser groups. Profilometric analyses and scanning electron microscopy (SEM) examinations were performed after applications and after a 5-day erosive-abrasive cycle. For the statistical analysis of surface roughness measurements, 2-way analysis of variance (ANOVA), 1-way ANOVA, and Tukey post hoc test were used. Results: Among the treatments, only DDAs alone did not cause increase in surface roughness after application. All of the laser applications increased the surface roughness of dentin, and after the erosion-abrasion cycle, all of the test groups had increased surface roughness. However, SEM images showed that morphological changes were less frequently observed in all of the experimental groups than in the control group. In addition, all of the laser-DDA combinations had stronger tubule occlusion effects than did DDAs alone, even after erosion-abrasion. Conclusions: All of the test treatments showed protective effects on dentin surfaces against the negative effects of erosion-abrasion. The addition of the laser to DDA applications increased tubular plugging efficiencies of DDAs, and the tubule plugs of the combination treatments were resistant to the erosion-abrasion cycle.
引用
收藏
页码:E35 / E51
页数:17
相关论文
共 28 条
  • [1] Occluding Efficiency of Different Desensitizing Agents and Er,Cr:YSGG Laser on Dentin Tubules
    Uslu, Y. S.
    Donmez, N.
    Gungor, A. S.
    Akalin, T. T.
    Ulukapi, H.
    OPERATIVE DENTISTRY, 2024, 49 (02) : 166 - 177
  • [2] Influence of Er,Cr:YSGG laser, associated or not to desensitizing agents, in the prevention of acid erosion in bovine root dentin
    Brenda Ferreira Arantes
    Laura de Oliveira Mendonça
    Regina Guenka Palma-Dibb
    Juliana Jendiroba Faraoni
    Denise Tornavoi de Castro
    Vinícius Rangel Geraldo-Martins
    Cesar Penazzo Lepri
    Lasers in Medical Science, 2019, 34 : 893 - 900
  • [3] Analysis of surface roughness of enamel and dentin after Er,Cr:YSGG laser irradiation
    Hossain, M
    Nakamura, Y
    Yamada, Y
    Suzuki, N
    Murakami, Y
    Matsumoto, K
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (06): : 297 - 303
  • [4] Influence of Er,Cr:YSGG laser, associated or not to desensitizing agents, in the prevention of acid erosion in bovine root dentin
    Arantes, Brenda Ferreira
    Mendonca, Laura de Oliveira
    Palma-Dibb, Regina Guenka
    Faraoni, Juliana Jendiroba
    de Castro, Denise Tornavoi
    Geraldo-Martins, Vinicius Rangel
    Lepri, Cesar Penazzo
    LASERS IN MEDICAL SCIENCE, 2019, 34 (05) : 893 - 900
  • [5] Er,Cr:YSGG Laser Surface Modification Effect on Dentin Bonding to Zirconia: An In Vitro Study
    Chemaly, Nancy
    Franzen, Rene
    Daou, Maha
    Karam, Mia
    Mhanna, Rami
    Kozlova, Yuliya
    Habre, Pascale
    PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY, 2022, 40 (08) : 573 - 579
  • [6] In Vitro Study of Er,Cr:YSGG Laser Effects When Used for the Prevention of Dentin Demineralization
    Ferreira, Elizabete dos Santos
    Kato Prates, Ilka Tiemy
    Machado dos Santos, Sergio Luiz, Jr.
    Del Valle, Matheus
    Zezell, Denise M.
    Ana, Patricia A.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2, 2019, 70 (02): : 825 - 829
  • [7] Effect of duration of Er,Cr:YSGG laser etching on dentin morphology: an in vitro study
    Mahdisiar F.
    Mirzaei A.
    Fallah A.
    Gutknecht N.
    Akhoundan S.
    Lasers in Dental Science, 2018, 2 (4) : 213 - 219
  • [9] Evaluation of microtensile bond strength of glass ionomer cements to dentin after conditioning with the Er, Cr: YSGG laser
    Jordehi, Atefeh Yousefi
    Ghasemi, Amir
    Zadeh, Maryam Moezi
    Fekrazad, Reza
    PHOTOMEDICINE AND LASER SURGERY, 2007, 25 (05) : 402 - 406
  • [10] Antibacterial effect of Er,Cr:YSGG laser and chlorhexidine 2% against Entrococcus faecalis in dentin tubules (in vitro study)
    Kangarloo, Ali
    Salar, Omid
    Zerafatjou, Golaleh
    Kalhori, Katayoun A. M.
    Sohrabi, Mona
    Fekrazad, Reza
    LASER PHYSICS, 2021, 31 (08)