DNAPL delineation with soil and groundwater sampling

被引:0
|
作者
Gavaskar, A [1 ]
Rosansky, S [1 ]
Naber, S [1 ]
Gupta, N [1 ]
Sass, B [1 ]
Sminchak, J [1 ]
DeVane, MP [1 ]
Holdsworth, T [1 ]
机构
[1] Battelle Mem Inst, Columbus, OH 43201 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chlorinated solvent contamination consisting primarily of trichloroethylene (TCE) is present at Launch Complex 34 (LC34), Cape Canaveral Air Station, Florida. The presence of dense nonaqueous phase liquid (DNAPL) was confirmed following groundwater and soil sampling for chlorinated volatile organic compounds (CVOCs) during preliminary site characterization. Detailed site characterization was conducted in two stages. The Stage 1 soil sampling in the suspected DNAPL zone was used to prepare a Stage 2 soil sampling plan based on a statistical design to map the DNAPL source zone boundaries, determine the horizontal and vertical distribution of the DNAPL, and estimate the total TCE and DNAPL masses. Groundwater(organic and inorganic) analysis and hydraulic parameter measurements were conducted to track the progress of the remediation, evaluate DNAPL migration potential, and evaluate aquifer quality before and after treatment. Depth-discrete soil and groundwater sampling was found to be an efficient way of characterizing the DNAPL source zone to enable the design of the remediation technology application, as well as to track remediation progress and effectiveness.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [1] Spatial in situ delineation of soil and groundwater contamination with environmental CPT
    Neuhaus, M
    FIELD SCREENING EUROPE 2001, 2002, : 71 - 78
  • [2] SOIL-GAS SURVEYS FOR DETECTION AND DELINEATION OF GROUNDWATER CONTAMINATION
    KERFOOT, HB
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1990, 9 (05) : 157 - 163
  • [3] Cone penetrometer testing for characterization and sampling of soil and groundwater
    Edelman, SH
    Holguin, AR
    SAMPLING ENVIRONMENTAL MEDIA, 1996, 1282 : 192 - 206
  • [4] Soil and groundwater sampling - How good is good practice?
    Epps, RJ
    Leonard, RE
    Robinson, SJ
    GEOENVIRONMENTAL ENGINEERING: CONTAMINATED GROUND: FATE OF POLLUTANTS AND REMEDIATION, 1998, : 17 - 25
  • [5] DNAPL distribution in the source zone: Effect of soil structure and uncertainty reduction with increased sampling density
    Pantazidou, Marina
    Liu, Ke
    JOURNAL OF CONTAMINANT HYDROLOGY, 2008, 96 (1-4) : 169 - 186
  • [6] Soil gas radon emanometry: A tool for delineation of fractures for groundwater in granitic terrains
    Reddy, D. V.
    Sukhija, B. S.
    Nagabhushanam, P.
    Reddy, G. K.
    Kumar, Devender
    Lachassagne, P.
    JOURNAL OF HYDROLOGY, 2006, 329 (1-2) : 186 - 195
  • [7] Delineation of groundwater and soil contamination using EM survey at an industrial abandoned site
    Zhang Shaohong
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [8] A multi-stage sampling strategy for the delineation of soil pollution in a contaminated brownfield
    Verstraete, S.
    Van Meirvenne, M.
    ENVIRONMENTAL POLLUTION, 2008, 154 (02) : 184 - 191
  • [9] Soil-landscape delineation to define spatial sampling domains for hillslope hydrology
    Park, SJ
    van de Giesen, N
    JOURNAL OF HYDROLOGY, 2004, 295 (1-4) : 28 - 46
  • [10] Effects of Tween 80 in groundwater on DNAPL migration and distribution
    Cheng, Zhou
    Xu, Hong-Xia
    Wu, Ji-Chun
    Wu, Ming
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (03): : 1068 - 1077