Common Carotid Artery Wall Localization in B-mode Ultrasound Images for Initialization of Artery Wall Tracking Methods

被引:0
|
作者
Dorazil, Jan [1 ]
Riha, Kamil [1 ]
Dutta, Malay Kishore [2 ]
机构
[1] Brno Univ Technol, Dept Telecommun, Brno, Czech Republic
[2] Dr APJ Abdul Kalam Tech Univ, Ctr Adv Studies, Lucknow, Uttar Pradesh, India
关键词
artery wall localization; B-mode; common carotid artery; ultrasound; Viola-Jones; TRANSVERSE SECTIONS;
D O I
10.1109/tsp.2019.8769077
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Analysis of the movement of the common carotid artery (CCA) wall in ultrasound sequences can be used for diagnosis of many cardiovascular diseases. In this paper we introduce a method for localization of the CCA wall contour (approximated by a circle) inside an ultrasound image, which can be used in real-time applications for initialization of an artery wall tracking method. First we detect a rectangular region of interest (ROI) using a recently proposed method based on the Viola-Jones detector. Next we perform an exhaustive search over all possible circles inside the ROI. Circle which maximizes a particular criterion represents the final estimate. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform in terms of precision and misdetection rates.
引用
收藏
页码:605 / 608
页数:4
相关论文
共 50 条
  • [1] B-MODE ULTRASOUND IMAGES OF THE CAROTID-ARTERY WALL - CORRELATION OF ULTRASOUND WITH HISTOLOGICAL MEASUREMENTS
    GAMBLE, G
    BEAUMONT, B
    SMITH, H
    ZORN, J
    SANDERS, G
    MERRILEES, M
    MACMAHON, S
    SHARPE, N
    ATHEROSCLEROSIS, 1993, 102 (02) : 163 - 173
  • [2] Carotid artery wall motion in humans, estimated from B-mode ultrasound images
    Golemati, S
    Sassano, A
    Lever, MJ
    Bharath, AA
    Dhanjil, S
    Nicolaides, AN
    JOURNAL OF PHYSIOLOGY-LONDON, 2000, 525 : 11P - 12P
  • [3] Quantification of the wall inhomogeneity in B-mode sonographic images of the carotid artery
    Sandrock, M
    Cheng, DC
    Schmitz, D
    Schmidt-Trucksäss, A
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (12) : 1395 - 1404
  • [4] Carotid artery wall motion estimated from B-mode ultrasound using region tracking and block matching
    Golemati, S
    Sassano, A
    Lever, MJ
    Bharath, AA
    Dhanjil, S
    Nicolaides, AN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 387 - 399
  • [5] Carotid Wall Motion Analysis Based on B-Mode Ultrasound Images
    Hopkins, Warren
    Gao, Hao
    Das, Saroj
    Long, Quan
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 871 - 874
  • [6] Automated detection of the carotid artery wall in B-mode ultrasound images using active contours initialized by the Hough transform
    Stoitsis, J.
    Golemati, S.
    Kendros, S.
    Nikita, K. S.
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 3146 - 3149
  • [7] Blood flow generation in B-MODE ultrasound images of the carotid artery
    Hamou, AK
    El-Sakka, MR
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 2945 - 2948
  • [8] Robust Carotid Artery Recognition in Longitudinal B-Mode Ultrasound Images
    Sifakis, Emmanouil G.
    Golemati, Spyretta
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2014, 23 (09) : 3762 - 3772
  • [9] Automatic segmentation of the lumen of the carotid artery in ultrasound B-mode images
    Santos, Andre M. F.
    Tavares, Joao Manuel R. S.
    Sousa, Luisa
    Santos, Rosa
    Castro, Pedro
    Azevedo, Elsa
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [10] Using two methods for recognition common carotid artery of B-mode longitudinal ultrasound image
    Wan, Jun
    Ruan, Qiuqi
    Li, Wei
    2010 IEEE 10TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS (ICSP2010), VOLS I-III, 2010, : 1753 - 1756