Characterization of large TSV MPPC arrays (4 x 4 ch and 8 x 8 ch) in scintillation spectrometry

被引:8
|
作者
Grodzicka-Kobylka, M. [1 ]
Szczesniak, T. [1 ]
Moszynski, M. [1 ]
Korolczuk, S. [1 ]
Baszak, J. [2 ]
Kapusta, M. [1 ]
机构
[1] Natl Ctr Nucl Res, A Soltana 7, PL-05400 Otwock, Poland
[2] Hamamatsu Photon Deutschland GmbH, Arzbergerstr 10, D-82211 Herrsching, Germany
关键词
MPPC; Energy resolution; Excess noise factor; SILICON PHOTOMULTIPLIERS; ENERGY RESOLUTION; LIGHT YIELD; BGO;
D O I
10.1016/j.nima.2017.07.006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The main objective of this work was to characterize the new multi-pixel photon counter (MPPC) arrays with a 12 x 12 mm(2) and a 24 x 24 mm(2) active area, made using through-silicon via (TSV) technology and with trenches introduced between the cells, in gamma-ray spectrometry with five different scintillators:CsI:Tl, NaI:Tl, LSO/ LYSO, BGO, and LaBr3. The results of the study are compared to those obtained previously with the older sample of the 12 x 12 mm(2) MPPC array made as a monolithic device. TSV MPPC array with the size of 24 x 24 mm(2) is one of the first commercially available SiPM with such a large active area and with the dead space between channels minimized to only 0.2 mm. Moreover, in these devices, Hamamatsu introduced trenches between cells to reduce cross-talk. Hence excess noise factor (ENF) was also reduced from a value of 1.7 to 1.2 in comparison to the "old'' monolithic sample (data for the same overvoltage of 1.3V). Whereby for the new MPPCs, the optimum operating voltage is higher by about 0.6V. In consequence, this higher optimal overvoltage means a higher photon detection efficiency (PDE) and number of photoelectrons, and leads to improved energy resolution. Energy resolution measured for the 662keV full energy peak in a Cs-137 gamma-source spectrum recorded with 12 x 12 mm(2) TSV MPPC and two CsI:Tl scintillators (12 x 12 x 12 mm(3) and 1 x 1 in) equals to 5.8% and 6.8%, respectively. For the "old'' MPPC with the same CsI:Tl scintillators energy resolution is equal to 6.4% and 7.1%, respectively. These improved TSV MPPC arrays can be commercially used for scintillation light readout of "large'' crystals with a diameter of 1 x 1 in or 2 x 2 in, suitable for gamma spectrometry in a wide range of applications. The combination of new 8 x 8 ch (24 x 24 mm(2)) TSV MPPC and 2 x 2 in NaI:Tl gives an excellent energy resolution below 8%, despite the incomplete match of the scintillator surface to the active area of MPPC and loss of the part of the light. (C) 2017 Published by Elsevier B. V.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 50 条
  • [1] Characterization of TSV MPPC Arrays (4x4 ch and 8x8 ch) in scintillation spectrometry
    Grodzicka, M.
    Szezesniak, T.
    Moszynski, M.
    Korolczuk, S.
    Baszak, J.
    Kapusta, M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Characterization of 4x4 ch MPPC array in scintillation spectrometry
    Grodzicka, M.
    Moszynski, M.
    Szczesniak, T.
    Szawlowski, M.
    Baszak, J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [3] Characterization of 4x4ch MPPC Array in Scintillation Spectrometry
    Grodzicka, M.
    Moszynski, M.
    Szczesniak, T.
    Szawlowski, M.
    Baszak, J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 327 - 330
  • [4] Gain-Integrated 8 x 8 Silicon Photonics Multicast Switch With On-Chip 2 x 4-ch. SOAs
    Konoike, Ryotaro
    Matsuura, Hiroyuki
    Suzuki, Keijiro
    Matsumoto, Takeshi
    Kurahashi, Teruo
    Uetake, Ayahito
    Takabayashi, Kazumasa
    Akiyama, Suguru
    Sekiguchi, Shigeaki
    Namiki, Shu
    Kawashima, Hitoshi
    Ikeda, Kazuhiro
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2020, 38 (11) : 2930 - 2937
  • [5] CMOS 4x4 and 8x8 Butler Matrices
    Cetinoneri, Berke
    Atesal, Yusuf A.
    Kim, Jeong-Geun
    Rebeiz, Gabriel M.
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 69 - 72
  • [6] REACTIONS OF S4N4 WITH DIPHOSPHINES, PH2P(X)PPH2 (X = NC4H8N, CH2CH2)
    THOMAS, CJ
    RAO, MNS
    ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 1993, 619 (02): : 433 - 436
  • [7] A 25 Gb/s x 4-ch, 8 x 8 mm2 small size optical transceiver module for optical interconnection
    Matsushima, Naoki
    Chujo, Norio
    Takai, Toshiaki
    Yazaki, Toru
    Kawamura, Daichi
    Matsuoka, Yasunobu
    Lee, Yong
    Yamashita, Hiroki
    Takemoto, Takashi
    Arimoto, Hideo
    Ishigami, Yoshiaki
    Yamazaki, Kinya
    Sunaga, Yoshinori
    2013 IEEE 3RD CPMT SYMPOSIUM JAPAN (ICSJ 2013), 2013,
  • [8] Design and Implementation of Single-Layer 4x4 and 8x8 Butler Matrices for Multibeam Antenna Arrays
    Adamidis, George A.
    Vardiambasis, Ioannis O.
    Ioannidou, Melina P.
    Kapetanakis, Theodoros N.
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2019, 2019
  • [9] Low-Complexity Integrated Architecture of 4x4, 4x8, 8x4 and 8x8 Inverse Integer Transforms of VC-1
    Wang, Yi-Jung
    Chang, Chih Chi
    Wu, Guo Zua
    Chen, Oscal T. -C.
    2009 52ND IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 2009, : 543 - +
  • [10] Atmospheric chemistry of CxF2x+1CH=CH2 (x=1, 2, 4, 6 and 8): Radiative efficiencies and global warming potentials
    Andersen, Mads P. Sulbaek
    Waterland, Robert L.
    Sander, Stanley P.
    Nielsen, Ole J.
    Wallington, Timothy J.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2012, 233 : 50 - 52