Solar beating for emergency diesel generators

被引:0
|
作者
Archibald, JP [1 ]
机构
[1] Amer Solar Inc, Annandale, VA 22003 USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Emergency diesel generators use large amounts of electric resistance heat to keep the engines warm and ready to start, all year. The annual electric use for mid sized generators (150 KW-1,000 KW) in outdoor enclosures can be 10,000 to 30,000 kwhr in mild climates with 4,000 heating degree days (65 F base). With over 600,000 emergency diesel generators installed in the US, standby electric heating consumes an estimated 6 billion kilowatt hours and $360 million per year. The electricity is consumed to heat the jacket water of the engine by means of an electric resistance cartridge heater. The heaters deliver 130 degree F water to the engine. An alternative to electric heating of the jacket water, is to solar heat the air in the enclosure up to 110 F. This reduces the heat loss from the engine and therefore reduces the electricity consumption of the electric resistance heater. The paper describes the opportunity to solar heat emergency generators. The design and construction of three systems for the US Geological Survey in Reston, VA is described.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [1] DETERMINATION OF THE RELIABILITY OF EMERGENCY DIESEL GENERATORS
    SOMMER, P
    ATOMKERNENERGIE-KERNTECHNIK, 1980, 35 (01): : 65 - 66
  • [2] Investigation on Performances and Functions of Power Emergency Diesel Generators
    Zhang, ZiChong
    Liu, YuQuan
    Mo, WenXiong
    Wang, HongBin
    An, ZhiGuo
    Liu, Han
    Luo, LinHuan
    Wang, Zhong
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 437 - 448
  • [3] Emergency Diesel Generators for Run Down Conditions.
    Anon
    Electra, 1983, (86): : 23 - 30
  • [4] Simulation and Dynamic Process Analysis of Nuclear Emergency Diesel Generators
    Yao Lian-fu
    Liu Qian
    Li Shi
    Zhang Zhen-yu
    PROCEEDINGS OF THE 2011 INTERNATIONAL CONFERENCE ON INFORMATICS, CYBERNETICS, AND COMPUTER ENGINEERING (ICCE2011), VOL 3: COMPUTER NETWORKS AND ELECTRONIC ENGINEERING, 2011, 112 : 107 - +
  • [5] Risk-informed testing program for emergency diesel generators
    Hämäläinen, A
    Jänkälä, K
    Vaurio, J
    PROBABILISTIC SAFETY ASSESSMENT AND MANAGEMENT, VOL 1- 6, 2004, : 2326 - 2331
  • [6] Technical article. Analysis of emergency diesel generators for improved reliability
    Krawczak, A.T.
    Wilson, B.K.
    Shock and Vibration Digest, 1994, 26 (03):
  • [7] Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions
    Marqusee, Jeffrey
    Jenket , Donald, II
    APPLIED ENERGY, 2020, 268 (268)
  • [8] COMPARISON OF COSTS FOR SOLAR ELECTRIC SOURCES WITH DIESEL GENERATORS IN REMOTE LOCATIONS
    MANASSE, FK
    REVUE DE PHYSIQUE APPLIQUEE, 1980, 15 (03): : 369 - 376
  • [9] Gamesa Electric signed the contract for the supply of ten generators for emergency diesel application
    不详
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2015, 60 (07): : 486 - 486
  • [10] AN AGING SIMULATION MODEL FOR THE EMERGENCY DIESEL GENERATORS OF ANGRA 2 BY SUPPLEMENTARY VARIABLES
    Santos de Oliveira, Iona Maghali
    Ferreira Frutuoso e Melo, Paulo Fernando
    de Pinho, Marcos Oliveira
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 1, 2008, : 27 - 33