Immediate postpartum etonogestrel implant: a contraception option with long-term continuation

被引:26
|
作者
Wilson, Susan [1 ]
Tennant, Corina [1 ]
Sammel, Mary D. [2 ,3 ]
Schreiber, Courtney [1 ]
机构
[1] Hosp Univ Penn, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Biostat & Epidemiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Perelman Sch Med, Ctr Clin Epidemiol & Biostat CCEB, Philadelphia, PA 19104 USA
关键词
Subdermal implant; Long-acting reversible contraception; Immediate postpartum contraception; Rapid repeat pregnancy; ACTING REVERSIBLE CONTRACEPTION; ADOLESCENTS; INITIATION; PREGNANCY; INSERTION;
D O I
10.1016/j.contraception.2014.05.006
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine 3-year continuation rates of the etonogestrel contraceptive implant when inserted immediately postpartum and to identify factors associated with discontinuation. Study Design: A retrospective cohort of 262 women who had the contraceptive implant inserted immediately postpartum between January 2008 and March 2009 was collected from electronic medical records. Continuation rates at 1, 2 and 3 years were estimated. Adverse effects leading to removal of the implant were recorded. Multivariable Cox proportional hazard models were performed to determine factors associated with early discontinuation. Results: Large subsets of the study patients were adolescent (28.2%) and multigravid (71.8%) and presented for fewer than six prenatal visits (38.5%). Follow-up rates were over 70% at each of the 3 years. Adolescents and women with fewer than six prenatal visits had the highest continuation rates at 1 year, 94.5% and 94.1%, respectively. The cumulative implant continuation rate after 3 years was 66.3%. Multivariable analysis indicated that having six or more prenatal care visits was the only independent predictor of early discontinuation, with a hazard ratio of 3.1 (p=0.04) and 1.8 (p=<0.01) at 1 and 3 years, respectively. The most commonly reported reasons for early removal were abnormal bleeding (41.2%) and weight gain (19.1%). Conclusion: The contraceptive implant has high continuation over its 3-year lifespan when inserted immediately postpartum. Continuation rates were highest among populations most vulnerable to rapid repeat and unintended pregnancies. Implications: The etonogestrel implant, when placed immediately postpartum for contraception, can have high continuation rates of use for up to 3 years duration. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [1] LONG-TERM CONTINUATION RATES AFTER IMMEDIATE POSTPARTUM INSERTION OF ETONOGESTREL IMPLANT IN A HIGH-RISK URBAN POPULATION
    Tennant, C.
    Schreiber, C.
    CONTRACEPTION, 2012, 86 (03) : 294 - 294
  • [2] OFFERING ADOLESCENTS IMMEDIATE POSTPARTUM ETONOGESTREL IMPLANT: CONTINUATION AND REPEAT PREGNANCY RATES
    Tocce, K.
    Jheeder, J.
    McHugh, C.
    Teal, S.
    CONTRACEPTION, 2011, 84 (03) : 303 - 303
  • [3] IMMEDIATE POSTPARTUM INSERTION OF ETONOGESTREL IMPLANT: IMPACT ON CONTINUATION AND SATISFACTION AT 12 MONTHS
    Eisenberg, D.
    Benzoni, N.
    Zhao, Q.
    Madden, T.
    Secura, G.
    CONTRACEPTION, 2014, 90 (03) : 318 - 319
  • [4] Immediate Postpartum Placement of an Etonogestrel Implant (Implanon) Improves Contraceptive Continuation and Reduces Unplanned Pregnancy
    Nodler, J. L.
    Smith, H. J.
    Arbuckle, J. L.
    Jauk, V. C.
    Hoover, K. H.
    Biggio, J. R.
    FERTILITY AND STERILITY, 2013, 99 (03) : S19 - S19
  • [5] UTILIZATION OF IMMEDIATE POSTPARTUM ETONOGESTREL CONTRACEPTIVE IMPLANT.
    Mills, B. B.
    Van Deman, J., III
    Heberlein, E. C.
    Picklesimer, A. H.
    FERTILITY AND STERILITY, 2016, 106 (03) : E8 - E8
  • [6] The subdermal etonogestrel implant is a safe and acceptable post-abortal method of long-term contraception
    Hanson, M.
    Connolly, S.
    Slater, S.
    CONTRACEPTION, 2008, 78 (02) : 172 - 173
  • [7] OFFERING ADOLESCENTS IMMEDIATE POSTPARTUM ETONOGESTREL IMPLANT: 2-YEAR CONTINUATION AND REPEAT PREGNANCY RATES
    Tocce, K.
    Sheeder, J.
    Teal, S.
    CONTRACEPTION, 2012, 86 (03) : 295 - 295
  • [8] CONTINUATION OF THE ETONOGESTREL IMPLANT IN WOMEN UNDERGOING IMMEDIATE POSTABORTION PLACEMENT
    Madden, T.
    Eisenberg, D.
    Zhao, Q.
    Buckel, C.
    Secura, G.
    Peipert, J.
    CONTRACEPTION, 2012, 86 (03) : 295 - 295
  • [9] Continuation of the Etonogestrel Implant in Women Undergoing Immediate Postabortion Placement
    Madden, Tessa
    Eisenberg, David L.
    Zhao, Qiuhong
    Buckel, Christina
    Secura, Gina M.
    Peipert, Jeffrey F.
    OBSTETRICS AND GYNECOLOGY, 2012, 120 (05): : 1053 - 1059
  • [10] Association of Immediate Postpartum Etonogestrel Implant Insertion and Venous Thromboembolism
    Floyd, Jessica L.
    Beasley, Anitra
    Swaim, Laurie S.
    Turrentine, Mark
    Nijjar, J. Biba
    OBSTETRICS AND GYNECOLOGY, 2020, 135 : 102S - 103S