Theoretical investigation of a humidification-dehumidification desalination system configured by a double-pass flat plate solar air heater

被引:60
|
作者
Yamali, Cemil [1 ]
Solmus, Ismail [1 ]
机构
[1] Middle E Tech Univ, Dept Engn Mech, TR-06531 Ankara, Turkey
关键词
solar desalination; humidification-dehumidification; double-pass flat plate solar air heater;
D O I
10.1016/j.desal.2006.02.053
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of this study is to investigate theoretically the effect of different system operating conditions, types of air heater, and some different design parameters and a weather condition on a solar water desalination system performance under the climatological conditions of Ankara (40 degrees N,33 degrees E), Turkey. For this purpose, a computer simulation program based on the mathematical model is developed by means of MATLAB software. In this simulation program, the fourth order Runge-Kutta method is used to solve the energy balance equations numerically. The desalination unit is configured by a double-pass flat plate solar air heater with two glass covers, humidifying tower, storage tank and dehumidifying exchanger. The system used in this work is based on the idea of closed water and open air cycles. Air is heated by using a double-pass solar air heater whereas water is not heated. The system productivity is increased up to 9% by using a double-pass solar air heater compared to a single-pass solar air heater and decreased about 30% without double-pass solar air heater under the same operating conditions. Significant development on the productivity of the system is achieved by increasing the humidifier inlet water and air mass flow rates. At a constant water mass flow rate, however, the productivity of the unit increases with the increasing of air mass flow rate to an optimum value and decreases after that value. In addition, theoretical results indicate that there is a significant improvement on the system performance as the inital water temperature and water mass in the storage tank is increased. Moreover, increasing the cooling water mass flow rate and decreasing its temperature lead to appreciable improvement on the unit productivity. It is also found that, the system performance is strongly affected by the double-pass solar air heater area and slightly influenced by the bottom heat loss coefficient of the solar air heater and storage tank (especially, when its temperature is lower than the ambient air temperature). Finally, the productivity of the unit that consists of a double-pass solar air heater with two glass covers is not influenced by the wind speed variations as much as double-pass solar air heater with one glass cover.
引用
收藏
页码:163 / 177
页数:15
相关论文
共 50 条
  • [1] Theoretical investigation on humidification-dehumidification desalination employing flat-plate solar water collector
    Shaikh, Javed Sikandar
    Ismail, Saleel
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (21) : 11835 - 11853
  • [2] Humidification-Dehumidification Desalination System Powered by Simultaneous Air-Water Solar Heater
    Soomro, Sadam Hussain
    Santosh, Ravichandran
    Bak, Chul-U
    Kim, Woo-Seung
    Kim, Young-Deuk
    SUSTAINABILITY, 2021, 13 (23)
  • [3] Thermal analysis of humidification-dehumidification desalination system based on evacuated tube solar air heater
    Tiwari, Abhishek
    Kumar, Amit
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (12) : 6585 - 6602
  • [4] Theoretical investigation of solar humidification-dehumidification desalination system using parabolic trough concentrators
    Mohamed, A. M. I.
    El-Minshawy, N. A.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (10) : 3112 - 3119
  • [5] Experimental Investigation of Humidification-Dehumidification Desalination System
    Kumar, Amit
    Tiwari, Abhishek
    JOURNAL OF POLYMER & COMPOSITES, 2024, 12 : S104 - S113
  • [6] Theoretical and experimental investigation of humidification-dehumidification desalination unit
    Amer, E. H.
    Kotb, H.
    Mostafa, G. H.
    El-Ghalban, A. R.
    DESALINATION, 2009, 249 (03) : 949 - 959
  • [7] Theoretical investigation of a direct-contact humidification-dehumidification desalination system
    Alvarez, Alejandro
    Carranza, Francisco
    Zavala, Ivett
    Sauceda, Daniel
    DESALINATION AND WATER TREATMENT, 2019, 142 : 11 - 23
  • [8] Theoretical and experimental study of a solar desalination unit based on humidification-dehumidification of air
    Moumouh, Jihane
    Tahiri, Mohamed
    Salouhi, Mohamed
    Balli, Lahcen
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (45) : 20818 - 20822
  • [9] Air humidification-dehumidification for a water desalination system using solar energy
    Orfi, J.
    Galanis, N.
    Laplante, M.
    DESALINATION, 2007, 203 (1-3) : 471 - 481
  • [10] Experimental investigation of a solar vacuum humidification-dehumidification (VHDH) desalination system
    Rahimi-Ahar, Zohreh
    Hatamipour, Mohammad Sadegh
    Ghalavand, Younes
    DESALINATION, 2018, 437 : 73 - 80