Oxygenation index, an indicator of optimal distending pressure during high-frequency oscillatory ventilation

被引:12
|
作者
van Genderingen, HR
van Vught, JA
Jansen, JRC
Duval, ELIM
Markhorst, DG
Versprille, A
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Clin Phys & Informat, NL-1007 MB Amsterdam, Netherlands
[2] Wilhelmina Childrens Hosp, Dept Pediat, Pediat Intens Care Unit, NL-3508 AB Utrecht, Netherlands
[3] Leiden Univ, Med Ctr, Dept Intens Care, NL-2300 RC Leiden, Netherlands
[4] Paola Childrens Hosp, Dept Pediat, Pediat Intens Care Unit, B-2020 Antwerp, Belgium
[5] Vrije Univ Amsterdam, Med Ctr, Dept Pediat, Pediat Intens Care Unit, NL-1007 MB Amsterdam, Netherlands
[6] Erasmus Univ, Dept Pulm Dis, Pathophysiol Lab, NL-3000 DR Rotterdam, Netherlands
关键词
acute lung injury; high-frequency oscillatory ventilation; oxygenation index; gas exchange;
D O I
10.1007/s00134-002-1368-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To test the hypothesis that, during high-frequency oscillatory ventilation (HFOV) of pigs with acute lung injury, the oxygenation index (OI = Paw*FIO2* 100/PaO2) is minimal at the lowest continuous distending pressure (Paw), where the physiological shunt fraction is below 0.1 (Paw(optimal)). Design and setting: Prospective, observational study in a university research laboratory. Subjects: Eight Yorkshire pigs weighing 12.0 +/- 0.5 kg, with lung injury induced by lung lavage. Interventions: After initiation of HFOV, the pigs were subjected to a stepwise increase of Paw to obtain under-inflation, optimal inflation and over-distension of the lungs (inflation) in series, followed by a similar decrease of Paw (deflation). Measurements and results: At each Paw level, the of and physiological shunt fraction were determined. The OI reached a minimum of 6.2 +/- 1.4 at Paw 30 +/- 4 cmH(2)O during inflation and a minimum of 2.4 +/- 0.3 at Paw 13 +/- 2 cmH(2)O during deflation. Paw(optimal) was 32 +/- 6 cmH(2)O on the inflation limb and 14 +/- 2 cmH(2)O on the deflation limb. The difference between the Paw at minimal OI and Paw(optimal) was -1.9 +/- 4.2 cmH(2)O (NS) during inflation and -1.5 +/- 1.6 cmH(2)O (p<0.05) during deflation. In 15 out of the 16 comparisons, the difference in Paw was within one step (+/- 3 cmH(2)O). Conclusion: The minimal OI is indicative for the Paw where oxygenation is optimal during HFOV in surfactant-depleted pigs.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 50 条
  • [1] Oxygenation index, an indicator of optimal distending pressure during high-frequency oscillatory ventilation?
    Huibert R. van Genderingen
    Johannus A. van Vught
    Jos R. Jansen
    Elisabeth L. Duval
    Dick G. Markhorst
    Adrian Versprille
    Intensive Care Medicine, 2002, 28 : 1151 - 1156
  • [2] Optimal continuous distending pressure during high frequency oscillatory ventilation
    Markhorst, DG
    Bertrand, JM
    INTENSIVE CARE MEDICINE, 1998, 24 (01) : 90 - 91
  • [3] Optimal continuous distending pressure during high frequency oscillatory ventilation
    D. G. Markhorst
    J. M. Bertrand
    Intensive Care Medicine, 1998, 24 (1) : B90 - 91
  • [4] Optimal continuous distending pressure during high frequency oscillatory ventilation - Reply
    Nelle, M
    Zilow, EP
    Linderkamp, O
    INTENSIVE CARE MEDICINE, 1998, 24 (01) : 91 - 92
  • [5] OXYGENATION INDEX IMPROVES WITH HIGH-FREQUENCY OSCILLATORY VENTILATION
    ACKERMAN, N
    TORRES, B
    PIMENTEL, B
    CURRAN, J
    CLINICAL RESEARCH, 1988, 36 (01): : A78 - A78
  • [6] OXYGENATION INDEX IMPROVES DURING WEANING FROM HIGH-FREQUENCY OSCILLATORY VENTILATION TO CONVENTIONAL VENTILATION
    TORRES, B
    PIMENTEL, B
    KANAREK, K
    DANIELS, R
    ACKERMAN, N
    CLINICAL RESEARCH, 1988, 36 (01): : A77 - A77
  • [7] RESPIRATORY INDUCTANCE PLETYSMOGRAPHY MAY IDENTIFY THE OPTIMAL CONTINUOUS DISTENDING PRESSURE IN PAEDIATRIC HIGH-FREQUENCY OSCILLATORY VENTILATION
    de Jager, P.
    Veldsema-Hakvoort, B.
    Kneyber, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S157 - S157
  • [8] Attenuation of pressure swings along the endotracheal tube is indicative of optimal distending pressure during high-frequency oscillatory ventilation in a model of acute lung injury
    van Genderingen, HR
    van Vught, AJ
    Duval, ELIM
    Markhorst, DG
    Jansen, JRC
    PEDIATRIC PULMONOLOGY, 2002, 33 (06) : 429 - 436
  • [9] AIRWAY PRESSURE MEASUREMENT DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    BOYNTON, BR
    MANNINO, FL
    MEATHE, EA
    KOPOTIC, RJ
    FRIEDERICHSEN, G
    CRITICAL CARE MEDICINE, 1984, 12 (01) : 39 - 43
  • [10] Volume and Pressure Delivery During Pediatric High-Frequency Oscillatory Ventilation
    Wong, Ronald
    Deakers, Timothy
    Hotz, Justin
    Khemani, Robinder G.
    Ross, Patrick A.
    Newth, Christopher J.
    PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (04) : E189 - E194