On Using Projective Relations for Calibration and Estimation in a Structured-Light Scanner

被引:0
|
作者
Dhillon, Daljit Singh [1 ]
Govindu, Venn Madhav [1 ]
机构
[1] Indian Inst Sci, Dept Elect Engn, Bangalore 560012, Karnataka, India
关键词
3D Reconstruction; Structured-Light Scanner; System Calibration; Projector Calibration; Homography; Cross-Ratio; MODEL;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
For structured-light scanners, the projective geometry between a projector-camera pair is identical to that of a camera-camera pair. Consequently, in conjunction with calibration, a variety of geometric relations are available for three-dimensional Euclidean reconstruction. In this paper, we use projector-camera epipolar properties and the projective invariance of the cross-ratio to solve for 3D geometry. A key contribution of our approach is the use of homographies induced by reference planes, along with a calibrated camera, resulting in a simple parametric representation for projector and system calibration. Compared to existing solutions that require an elaborate calibration process, our method is simple while ensuring geometric consistency. Our formulation using the invariance of the cross-ratio is also extensible to multiple estimates of 3D geometry that can be analysed in a statistical sense. The performance of our system is demonstrated on some cultural artifacts and geometric surfaces.
引用
收藏
页码:831 / 842
页数:12
相关论文
共 50 条
  • [1] Geometric and radiometric estimation in a structured-light 3D scanner
    Daljit Singh Dhillon
    Venu Madhav Govindu
    Machine Vision and Applications, 2015, 26 : 339 - 352
  • [2] Geometric and radiometric estimation in a structured-light 3D scanner
    Dhillon, Daljit Singh
    Govindu, Venu Madhav
    MACHINE VISION AND APPLICATIONS, 2015, 26 (2-3) : 339 - 352
  • [3] Calibration of lens distortion by structured-light scanning
    Sagawa, R
    Takatsuji, M
    Echigo, T
    Yagi, Y
    2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, Vols 1-4, 2005, : 1349 - 1354
  • [4] A Flexible Stereo Calibration for a Structured-light Profilometer
    Bevilacqua, M.
    Di Leo, G.
    Landi, M.
    Liguori, C.
    Paciello, V.
    Paolillo, A.
    Pietrosanto, A.
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 1026 - 1031
  • [5] Accuracy Assessment of Structured-Light Based Industrial Optical Scanner
    Jovanovic, Vedran
    Dalic, Velibor
    Maric, Petar
    2022 21ST INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2022,
  • [6] CALIBRATION OF A MULTISENSOR STRUCTURED LIGHT RANGE SCANNER
    GODHWANI, A
    BHATIA, G
    VANNIER, MW
    OPTICAL ENGINEERING, 1994, 33 (04) : 1359 - 1367
  • [7] The comparison of camera calibration methods based on structured-light measurement
    Feng, Xiuxia
    Cao, Maoyong
    Wang, Haixia
    Collier, Michael
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 2, PROCEEDINGS, 2008, : 155 - 160
  • [8] Calibration of a structured light system: A projective approach
    Huynh, DQ
    1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, : 225 - 230
  • [9] Flexible calibration of structured-light systems projecting point patterns
    Ben-Hamadou, Achraf
    Soussen, Charles
    Daul, Christian
    Blondel, Walter
    Wolf, Didier
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2013, 117 (10) : 1468 - 1481
  • [10] The Application of Camera Calibration Methods Based on Structured-Light Measurement
    Feng, Xiuxia
    Cao, Maoyong
    Wang, Haixia
    Collier, Michael
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 5090 - 5094