A study on the electroanalytical performance of a bismuth film-coated and Nafion-coated glassy carbon electrode in alkaline solutions

被引:19
|
作者
Li, Dongyue [2 ]
Jia, Jianbo [1 ]
Wang, Jianguo [2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
[2] Liaoning Univ, Coll Chem, Shenyang 110036, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Bismuth film electrode; Nafion; Lead; Alkaline solution; ANODIC-STRIPPING VOLTAMMETRY; DIAMOND THIN-FILM; TRACE-METALS; PASTE ELECTRODES; COMPOSITE FILM; LEAD; POTENTIALITIES; CADMIUM;
D O I
10.1007/s00604-010-0337-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bismuth film electrodes are widely used for determination of heavy metal ions in acidic solutions, while alkaline solutions are rarely employed. We have compared the deposition of Bi(III) and Pb(II) on a Nafion-coated glassy carbon electrode in alkaline and acidic solutions. The results indicate that both Bi(III) and Pb(II) can be deposited in either alkaline or acidic solution, but the quantity of Pb(II) deposited in alkaline solution is less than that in acidic solution. The modified electrode was used to determine heavy metal ions in both alkaline and acidic solutions, and the results of the method agree well with those of atomic absorption spectroscopy.