Development of an automaton model of rotational activity driving atrial fibrillation

被引:11
|
作者
Ciaccio, E. J. [1 ]
Biviano, A. B. [1 ]
Wan, E. Y. [1 ]
Peters, N. S. [2 ]
Garan, H. [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Med, Div Cardiol, New York, NY USA
[2] Imperial Coll London, Dept Med, Cardiovasc Sci, London, England
关键词
Atrial fibrillation; Conduction block; Rotational activity; Rotor; Vortex; INFARCT BORDER ZONE; ROTOR MODULATION; FOCAL IMPULSE; FRACTIONATED ELECTROGRAMS; VENTRICULAR-TACHYCARDIA; CHAMBER QUANTIFICATION; CONVENTIONAL ABLATION; REENTRANT CIRCUITS; CATHETER ABLATION; CARDIAC-MUSCLE;
D O I
10.1016/j.compbiomed.2017.02.008
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Atrial fibrillation (AF) is difficult to treat effectively, owing to uncertainty in where to best ablate to eliminate arrhythmogenic substrate. A model providing insight into the electrical activation events would be useful to guide catheter ablation strategy. Method A two-dimensional, 576x576 node automaton was developed to simulate atrial electrical activity. The substrate field was altered by the presence of differing refractory period at varying locations. Fibrosis was added in the form of short, randomly positioned lines of conduction block. Larger areas of block were used to simulate ablation lesions. Anisotropy was imposed in a 2:1 ratio. A premature electrical impulse from one of four grid corners was utilized to initiate activation. Results: Rotational activity was uninducible when refractory patch dimensions were less than 20x20 mm. For larger refractory regions, a single premature stimulus was capable of inducing an average of 1.19 +/- 1.10 rotors, which often formed near the patch edges. A maximum of 5 rotors formed when refractory patch dimensions approached the size of the entire left atrial virtual field. Rotors formed along a refractory patch edge, after wavefront arrival was delayed at turning points or due to the presence of a fiber cluster of sufficient size. However, rotational activity could also occur around a large fiber cluster without the need of spatially variable refractoriness. When obstacles to conduction were lacking in size, nascent rotors drifted and either extinguished, or stabilized upon anchoring at a sufficiently large fiber cluster elsewhere in the field. Transient rotors terminated when traversing a region with differing refractory periods, if no obstacle to conduction was present to sufficiently delay wavefront arrival beyond the longest refractory period. Other rotors were annihilated when a nearby rotor with faster spin rate gradually interrupted the activation pathway. Elimination of anchors by removal, or by simulated ablation over a sufficient region, prevented rotor onset at a particular location where it would otherwise form. Conclusions: The presence of obstacles to conduction and spatial differences in refractory period are important parameters for initiating and maintaining rotational activity in this simulation of an atrial substrate.
引用
收藏
页码:166 / 181
页数:16
相关论文
共 50 条
  • [1] Catheter ablation of rotational activity in atrial fibrillation: A barren oasis?
    Piccini, Jonathan P.
    Calkins, Hugh
    AMERICAN HEART JOURNAL, 2018, 205 : 142 - 144
  • [2] Real-Time Rotational Activity Detection in Atrial Fibrillation
    Rios-Munoz, Gonzalo R.
    Arenal, Angel
    Artes-Rodriguez, Antonio
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [3] Mechanisms of stochastic onset and termination of atrial fibrillation studied with a cellular automaton model
    Lin, Yen Ting
    Chang, Eugene T. Y.
    Eatock, Julie
    Galla, Tobias
    Clayton, Richard H.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2017, 14 (128)
  • [4] Rotational angiography for atrial fibrillation ablation
    Plank, F.
    Rahn, N.
    Till, D.
    Schgoer, W.
    Hintringer, F.
    Feuchtner, G.
    Stuehlinger, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 133 - 133
  • [5] Increased arrhythmia stability in hypertensive heart disease is not associated with increased rotational activity in porcine model of atrial fibrillation
    Manninger, M.
    Zweiker, D.
    van Hunnik, A.
    Zirngast, B.
    Alogna, A.
    Zeemering, S.
    Herbst, V.
    Schotten, U.
    Brussee, H.
    Pieske, B. M.
    Heinzel, F. R.
    Post, H.
    Scherr, D.
    WIENER KLINISCHE WOCHENSCHRIFT, 2017, 129 : S2 - S3
  • [6] A Modified Sensitive Driving Cellular Automaton Model
    GE Hong-Xia DAI Shi-Qiang DONG Li-Yun LEI Li Shanghai Institute of Applied Mathematics and Mechanics
    CommunicationsinTheoreticalPhysics, 2005, 43 (02) : 321 - 324
  • [7] A modified sensitive driving cellular automaton model
    Ge, HX
    Dai, SQ
    Dong, LY
    Lei, L
    COMMUNICATIONS IN THEORETICAL PHYSICS, 2005, 43 (02) : 321 - 324
  • [8] Bioelectric model of atrial fibrillation:: Applicability of blind source separation techniques for atrial activity estimation in atrial fibrillation episodes
    Rieta, JJ
    Castells, F
    Sánchez, C
    Moratal-Pérez, D
    Millet, J
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 525 - 528
  • [9] Rotational activity presence and its impact in persistent atrial fibrillation follow-up
    Rios-Munoz, G. R.
    Soto, N.
    Avila, P.
    Datino, T.
    Atienza, F.
    Gonzalez-Torrecilla, E.
    Fernandez-Aviles, F.
    Arenal, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 375 - 375
  • [10] CELLULAR AUTOMATON MODEL OF VENTRICULAR-FIBRILLATION
    MITCHELL, RH
    BAILEY, AH
    ANDERSON, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (03) : 253 - 259