Picoliter Well Array Chip-Based Digital Recombinase Polymerase Amplification for Absolute Quantification of Nucleic Acids

被引:36
|
作者
Li, Zhao [1 ]
Liu, Yong [1 ]
Wei, Qingquan [1 ]
Liu, Yuanjie [1 ]
Liu, Wenwen [1 ]
Zhang, Xuelian [1 ]
Yu, Yude [1 ,2 ]
机构
[1] Chinese Acad Sci, State Key Lab Integrated Optoelect, Inst Semicond, POB 912, Beijing 100083, Peoples R China
[2] Chinese Acad Sci, Joint Lab Bioinformat Acquisit & Sensing Technol, Inst Semicond, Beijing Inst Genom, POB 912, Beijing 100083, Peoples R China
来源
PLOS ONE | 2016年 / 11卷 / 04期
关键词
MEDIATED ISOTHERMAL AMPLIFICATION; REAL-TIME; DNA AMPLIFICATION; DROPLET FORMATION; CHAIN-REACTION; PCR; EMULSIFICATION; DEVICES; PLASMA;
D O I
10.1371/journal.pone.0153359
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Absolute, precise quantification methods expand the scope of nucleic acids research and have many practical applications. Digital polymerase chain reaction (dPCR) is a powerful method for nucleic acid detection and absolute quantification. However, it requires thermal cycling and accurate temperature control, which are difficult in resource-limited conditions. Accordingly, isothermal methods, such as recombinase polymerase amplification (RPA), are more attractive. We developed a picoliter well array (PWA) chip with 27,000 consistently sized picoliter reactions (314 pL) for isothermal DNA quantification using digital RPA (dRPA) at 39 degrees C. Sample loading using a scraping liquid blade was simple, fast, and required small reagent volumes (i.e., < 20 mu L). Passivating the chip surface using a methoxy-PEG-silane agent effectively eliminated cross-contamination during dRPA. Our creative optical design enabled wide-field fluorescence imaging in situ and both end-point and real-time analyses of picoliter wells in a 6-cm(2) area. It was not necessary to use scan shooting and stitch serial small images together. Using this method, we quantified serial dilutions of a Listeria monocytogenes gDNA stock solution from 9 x 10(-1) to 4 x 10(-3) copies per well with an average error of less than 11% (N = 15). Overall dRPA-on-chip processing required less than 30 min, which was a 4-fold decrease compared to dPCR, requiring approximately 2 h. dRPA on the PWA chip provides a simple and highly sensitive method to quantify nucleic acids without thermal cycling or precise micropump/microvalve control. It has applications in fast field analysis and critical clinical diagnostics under resource-limited settings.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Microfluidic Digital Chip for Absolute Quantification of Nucleic Acid Amplification
    Zhu Qiang-Yuan
    Yang Wen-Xiu
    Gao Yi-Bo
    Yu Bing-Wen
    Qiu Lin
    Zhou Chao
    Jin Wei
    Jin Qin-Han
    Mu Ying
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2013, 34 (03): : 545 - 550
  • [2] Absolute quantification of infecting viral particles by chip-based digital polymerase chain reaction
    McMullen, Africa
    Martinez-Hernandez, Francisco
    Martinez-Garcia, Manuel
    ENVIRONMENTAL MICROBIOLOGY REPORTS, 2019, 11 (06): : 855 - 860
  • [3] Digital Isothermal Quantification of Nucleic Acids via Simultaneous Chemical Initiation of Recombinase Polymerase Amplification Reactions on SlipChip
    Shen, Feng
    Davydova, Elena K.
    Du, Wenbin
    Kreutz, Jason E.
    Piepenburg, Olaf
    Ismagilov, Rustem F.
    ANALYTICAL CHEMISTRY, 2011, 83 (09) : 3533 - 3540
  • [4] Nucleic Acid Quantification with Amplicon Yield in Recombinase Polymerase Amplification
    Valloly, Priyanka
    Roy, Rahul
    ANALYTICAL CHEMISTRY, 2022, 94 (40) : 13897 - 13905
  • [5] Chip-Based and Wearable Tools for Isothermal Amplification and Electrochemical Analysis of Nucleic Acids
    Patiti, Claudia
    Sfragano, Patrick Severin
    Laschi, Serena
    Pillozzi, Serena
    Boddi, Anna
    Crociani, Olivia
    Bernini, Andrea
    Palchetti, Ilaria
    CHEMOSENSORS, 2022, 10 (07)
  • [6] Monte Carlo Modeling-Based Digital Loop-Mediated Isothermal Amplification on a Spiral Chip for Absolute Quantification of Nucleic Acids
    Xia, Yun
    Yan, Shuangqian
    Zhang, Xian
    Ma, Peng
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    ANALYTICAL CHEMISTRY, 2017, 89 (06) : 3716 - 3723
  • [7] An automated, dead-volume reduced, isothermal digital nucleic acid quantification system based on recombinase polymerase amplification
    Zhang, Zhongping
    Zhu, Rui
    Li, Tianwei
    Wang, Nan
    Zhang, Lulu
    Mauk, Michael G.
    Miao, Guijun
    Qiu, Xianbo
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2025,
  • [8] Absolute quantification of DNA methylation using microfluidic chip-based digital PCR
    Wu, Zhenhua
    Bai, Yanan
    Cheng, Zule
    Liu, Fangming
    Wang, Ping
    Yang, Dawei
    Li, Gang
    Jin, Qinghui
    Mao, Hongju
    Zhao, Jianlong
    BIOSENSORS & BIOELECTRONICS, 2017, 96 : 339 - 344
  • [9] Digital recombinase polymerase amplification in hydrogel nanofluidic chip for ultrafast and precise quantification of pathogens in fresh food
    Luo, Zisheng
    Lu, Yating
    Sun, Yuhao
    Wang, Yiru
    Su, Bin
    Lin, Xingyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 367
  • [10] Digital recombinase polymerase amplification chip based on asymmetric contact angle composite interface
    Zhang, Zhongping
    Li, Tianwei
    Tan, Yao
    Liu, Luyao
    Chen, Hao
    Zhang, Lulu
    Mauk, Michael G.
    Qiu, Xianbo
    ANALYTICA CHIMICA ACTA, 2025, 1337