High-flux ptychographic imaging using the new 55 μm-pixel detector 'Lambda' based on the Medipix3 readout chip

被引:14
|
作者
Wilke, R. N. [1 ]
Wallentin, J. [1 ]
Osterhoff, M. [1 ]
Pennicard, D. [2 ]
Zozulya, A. [2 ]
Sprung, M. [2 ]
Salditt, T. [1 ]
机构
[1] Univ Gottingen, Inst Xray Phys, D-37077 Gottingen, Germany
[2] Deutsch Elektronen Synchrotron DESY, D-22607 Hamburg, Germany
关键词
phase retrieval; ptychography; coherent diffractive imaging; semi-transparent central stop; semi-transparent beam stop; Lambda detector; Medipix3; chip; solar-cell nanowires; RAY-DIFFRACTION MICROSCOPY; PRIMARY WAVE FIELDS; PHASE RETRIEVAL; NONPERIODIC OBJECTS; RESOLUTION; ALGORITHM; RECONSTRUCTION; OPTICS; OPTIMIZATION; TRANSMISSION;
D O I
10.1107/S2053273314014545
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Suitable detection systems that are capable of recording high photon count rates with single-photon detection are instrumental for coherent X-ray imaging. The new single-photon-counting pixel detector `Lambda' has been tested in a ptychographic imaging experiment on solar-cell nanowires using Kirkpatrick-Baez-focused 13.8keV X-rays. Taking advantage of the high count rate of the Lambda and dynamic range expansion by the semi-transparent central stop, a high-dynamic-range diffraction signal covering more than seven orders of magnitude has been recorded, which corresponds to a photon flux density of about 10(5)photonsnm(-2)s(-1) or a flux of approximate to 10(10)photonss(-1) on the sample. By comparison with data taken without the semi-transparent central stop, an increase in resolution by a factor of 3-4 is determined: from about 125nm to about 38nm for the nanowire and from about 83nm to about 21nm for the illuminating wavefield.
引用
收藏
页码:552 / 562
页数:11
相关论文
共 4 条
  • [1] Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E.
    Llopart, X.
    Tlustos, L.
    Wong, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S15 - S18
  • [2] The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging
    Ballabriga, R.
    Alozy, J.
    Blaj, G.
    Campbell, M.
    Fiederle, M.
    Frojdh, E.
    Heijne, E. H. M.
    Llopart, X.
    Pichotka, M.
    Procz, S.
    Tlustos, L.
    Wong, W.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [3] A high resolution, high frame rate detector based on a microchannel plate readout with the Medipix2 counting CMOS pixel chip
    Mikulec, B
    Vallerga, JV
    McPhate, JB
    Tremsin, AS
    Siegmund, OHW
    Clark, AG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1021 - 1026
  • [4] SMARTPIX, a photon-counting pixel detector for synchrotron applications based on Medipix3RX readout chip and active edge pixel sensors
    Ponchut, C.
    Collet, E.
    Herve, C.
    Le Caer, T.
    Cerrai, J.
    Siron, L.
    Dabin, Y.
    Ribois, J. F.
    JOURNAL OF INSTRUMENTATION, 2015, 10