Visualization and Quantification of Nasal and Olfactory Deposition in a Sectional Adult Nasal Airway Cast
被引:61
|
作者:
Xi, Jinxiang
论文数: 0引用数: 0
h-index: 0
机构:
Cent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Xi, Jinxiang
[1
]
Yuan, Jiayao Eddie
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Dept Mech Engn, New York, NY 10027 USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Yuan, Jiayao Eddie
[2
]
Zhang, Yu
论文数: 0引用数: 0
h-index: 0
机构:
Cent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Zhang, Yu
[1
]
Nevorski, Dannielle
论文数: 0引用数: 0
h-index: 0
机构:
Cent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Nevorski, Dannielle
[1
]
Wang, Zhaoxuan
论文数: 0引用数: 0
h-index: 0
机构:
Cent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Wang, Zhaoxuan
[1
]
Zhou, Yue
论文数: 0引用数: 0
h-index: 0
机构:
Lovelace Resp Res Inst, Aerosol & Resp Dosimetry Program, Albuquerque, NY USACent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
Zhou, Yue
[3
]
机构:
[1] Cent Michigan Univ, Sch Engn & Technol, 1200 South Franklin St, Mt Pleasant, MI 48858 USA
[2] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[3] Lovelace Resp Res Inst, Aerosol & Resp Dosimetry Program, Albuquerque, NY USA
To compare drug deposition in the nose and olfactory region with different nasal devices and administration techniques. A Sar-Gel based colorimetry method will be developed to quantify local deposition rates. A sectional nasal airway cast was developed based on an MRI-based nasal airway model to visualize deposition patterns and measure regional dosages. Four nasal spray pumps and four nebulizers were tested with both standard and point-release administration techniques. Delivered dosages were measured using a high-precision scale. The colorimetry correlation for deposited mass was developed via image processing in Matlab and its performance was evaluated through comparison to experimental measurements. Results show that the majority of nasal spray droplets deposited in the anterior nose while only a small fraction (less than 4.6%) reached the olfactory region. For all nebulizers considered, more droplets went beyond the nasal valve, leading to distinct deposition patterns as a function of both the nebulizer type (droplet size and initial speed) and inhalation flow rate. With the point-release administration, up to 9.0% (+/- 1.9%) of administered drugs were delivered to the olfactory region and 15.7 (+/- 2.4%) to the upper nose using Pari Sinus. Standard nasal devices are inadequate to deliver clinically significant olfactory dosages without excess drug losses in other nasal epitheliums. The Sar-Gel based colorimetry method appears to provide a simple and practical approach to visualize and quantify regional deposition.
机构:
Lovelace Respiratory Research Institute, P.O. Box 5890, Albuquerque, NM 87185-5890, United StatesLovelace Respiratory Research Institute, P.O. Box 5890, Albuquerque, NM 87185-5890, United States
Zwartz, G.J.
Smuin, S.R.
论文数: 0引用数: 0
h-index: 0
机构:
University of Iowa, Biomedical Engineering, 1042 Engineering Building, Iowa City, IA 52242, United StatesLovelace Respiratory Research Institute, P.O. Box 5890, Albuquerque, NM 87185-5890, United States
Smuin, S.R.
Guilmette, R.A.
论文数: 0引用数: 0
h-index: 0
机构:
Lovelace Respiratory Research Institute, P.O. Box 5890, Albuquerque, NM 87185-5890, United StatesLovelace Respiratory Research Institute, P.O. Box 5890, Albuquerque, NM 87185-5890, United States