Solitary pulmonary nodules - Optimal slice thickness of high-resolution CT in differentiating malignant from benign

被引:12
|
作者
Iwano, S
Makino, N
Ikeda, M
Itoh, S
Tadokoro, M
Satake, H
Ishigaki, T
机构
[1] Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, Nagoya, Aichi 46685500, Japan
[2] Toyota Mem Hosp, Dept Radiol, Nagoya, Aichi, Japan
[3] Nagoya Univ, Sch Med, Dept Med Informat & Records, Nagoya, Aichi 46685500, Japan
[4] Nagoya Univ, Sch Med, Dept Med Informat & Records, Nagoya, Aichi 46685500, Japan
[5] Nagoya Univ, Sch Hlth Sci, Dept Radiol Technol, Nagoya, Aichi, Japan
关键词
cancer; high-resolution computed tomography; solitary pulmonary nodules;
D O I
10.1016/S0899-7071(03)00282-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine an optimal slice thickness that was efficient in differentiating malignant from benign solitary pulmonary nodules (SPNs) on high-resolution computed tomography (HRCT) images. For a total of 92 SPNs, four radiologist indicated their confidence level for the malignant or benign SPN on the CT images presented in 1-, 3-, and 5-mm slice thickness. HRCT could be used to differentiate more accurately the malignant nodules from the benign ones using 1-mm-thick sections than 3- or 5-mm-thick sections. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:322 / 328
页数:7
相关论文
共 50 条
  • [1] Computer-aided differentiation of malignant from benign solitary pulmonary nodules imaged by high-resolution CT
    Iwano, Shingo
    Nakamura, Tatsuya
    Kamioka, Yuko
    Ikeda, Mitsuru
    Ishigaki, Takeo
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (05) : 416 - 422
  • [2] Diagnostic value of PET/CT in differentiating benign from malignant solitary pulmonary nodules
    Dalli, A.
    Sen, H. Selimoglu
    Coskunsel, M.
    Komek, H.
    Abakay, O.
    Sergi, C.
    Tanrikulu, A. Cetin
    JOURNAL OF BUON, 2013, 18 (04): : 935 - 941
  • [3] Usefulness of computerized scheme for differentiating benign from malignant lung nodules on high-resolution CT
    Li, F
    Li, Q
    Aoyama, M
    Shiraishi, J
    Abe, H
    Suzuki, K
    Engelmann, R
    Sone, S
    MacMahon, H
    Doi, K
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 946 - 951
  • [4] The role of HRCT in differentiating benign from malignant solitary pulmonary nodules
    Potente, G
    Palmeggiani, F
    Iacari, V
    Macori, F
    Caimi, M
    Misiti, A
    Anaveri, G
    2ND INTERNATIONAL CONGRESS ON LUNG CANCER, 1996, : 189 - 192
  • [5] Usefulness of an artificial neural network for differentiating benign from malignant pulmonary nodules on high-resolution CT: Evaluation with receiver operating characteristic analysis
    Matsuki, Y
    Nakamura, K
    Watanabe, H
    Aoki, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 657 - 663
  • [6] The value of radiomics based on dual-energy CT for differentiating benign from malignant solitary pulmonary nodules
    Liang, Gao
    Yu, Wei
    Liu, Shu-Qin
    Xie, Ming-Guo
    Liu, Min
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [7] The value of radiomics based on dual-energy CT for differentiating benign from malignant solitary pulmonary nodules
    Gao Liang
    Wei Yu
    Shu-qin Liu
    Ming-guo Xie
    Min Liu
    BMC Medical Imaging, 22
  • [8] The Value of LDH Level of BAL Fluid in Differentiating Benign from Malignant Solitary Pulmonary Nodules
    Emad, A.
    Jannati, M.
    Amooee, S.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2007, 32 (03) : 137 - 142
  • [9] The value of BAL fluid LDH level in differentiating benign from malignant solitary pulmonary nodules
    Ali Emad
    Vahid Emad
    Journal of Cancer Research and Clinical Oncology, 2008, 134 : 489 - 493
  • [10] The value of BAL fluid LDH level in differentiating benign from malignant solitary pulmonary nodules
    Emad, Ali
    Emad, Vahid
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2008, 134 (04) : 489 - 493