Cost-effectiveness of cardiac resynchronization therapy plus an implantable cardioverter-defibrillator in patients with heart failure: a systematic review

被引:4
|
作者
Teimourizad, Abedin [1 ]
Rezapour, Aziz [2 ]
Sadeghian, Saeed [3 ]
Tajdini, Masih [3 ]
机构
[1] Iran Univ Med Sci, Sch Hlth Management & Informat Sci, Dept Hlth Econ, Tehran, Iran
[2] Iran Univ Med Sci, Hlth Management & Econ Res Ctr, Sch Hlth Management & Informat Sci, Tehran, Iran
[3] Univ Tehran Med Sci, Tehran Heart Ctr, Tehran, Iran
关键词
Heart failure; Cost-effectiveness; Implantable cardiac devices; Systematic review; ECONOMIC EVALUATIONS; GENERALIZABILITY; EPIDEMIOLOGY; UNCERTAINTY; DIAGNOSIS;
D O I
10.1186/s12962-021-00285-5
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction Heart failure (HF) is an unusual heart function that causes reduction in cardiac or pulmonary output. Cardiac resynchronization therapy (CRT) is a mechanical device that helps to recover ventricular dysfunction by pacing the ventricles. This study planned to systematically review cost-effectiveness of CRT combined with an implantable cardioverter-defibrillator (ICD) versus ICD in patients with HF. Methods We used five databases (NHS Economic Evaluation Database, Cochrane Library, Medline, PubMed, and Scopus) to systematically reviewed studies published in the English language on the cost-effectiveness of CRT with defibrillator (CRT-D) Vs. ICD in patients with HF over 2000 to 2020. Consolidated Health Economic Evaluation Reporting Standards (CHEERS) checklist was applied to assess the quality of the selected studies. Results Five studies reporting the cost-effectiveness of CRT-D vs ICD were finally identified. The results revealed that time horizon, direct medical costs, type of model, discount rate, and sensitivity analysis obviously mentioned in almost all studies. All studies used quality-adjusted life years (QALYs) as an effectiveness measurement. The highest and the lowest Incremental cost-effectiveness ratio (ICER) were reported in the USA ($138,649per QALY) and the UK ($41,787per QALY), respectively. Conclusion Result of the study showed that CRT-D compared to ICD alone was the most cost-effective treatment in patients with HF.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Cost-effectiveness of cardiac resynchronization therapy plus an implantable cardioverter-defibrillator in patients with heart failure: a systematic review
    Abedin Teimourizad
    Aziz Rezapour
    Saeed Sadeghian
    Masih Tajdini
    Cost Effectiveness and Resource Allocation, 19
  • [2] Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure
    Woo, Christopher Y.
    Strandberg, Erika J.
    Schmiegelow, Michelle D.
    Pitt, Allison L.
    Hlatky, Mark A.
    Owens, Douglas K.
    Goldhaber-Fiebert, Jeremy D.
    ANNALS OF INTERNAL MEDICINE, 2015, 163 (06) : 417 - +
  • [3] Incidence of Appropriate Cardioverter-Defibrillator Shocks and Mortality in Patients With Heart Failure Treated With Combined Cardiac Resynchronization Plus Implantable Cardioverter-Defibrillator Therapy Versus Implantable Cardioverter-Defibrillator Therapy
    Desai, Harit
    Aronow, Wilbert S.
    Ahn, Chul
    Tsai, Fausan S.
    Lai, Hoang M.
    Gandhi, Kaushang
    Amin, Harshad
    Frishman, William H.
    Kalapatapu, Kumar
    Cohen, Martin
    Sorbera, Carmine
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY AND THERAPEUTICS, 2010, 15 (01) : 37 - 40
  • [4] The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator
    Yao, Guiqing
    Freemantle, Nick
    Calvert, Melanie J.
    Bryan, Stirling
    Daubert, Jean-Claude
    Cleland, John G. F.
    EUROPEAN HEART JOURNAL, 2007, 28 (01) : 42 - 51
  • [5] Cost-effectiveness of implantable cardioverter-defibrillator
    不详
    HEART RHYTHM, 2006, 3 (01) : 126 - 126
  • [6] COST-EFFECTIVENESS OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    DELISSOVOY, G
    GUARNIERI, T
    PROGRESS IN CARDIOVASCULAR DISEASES, 1993, 36 (03) : 209 - 213
  • [7] Economic Implications and Cost-effectiveness of Implantable Cardioverter Defibrillator and Cardiac Resynchronization Therapy
    Bernard, Michael L.
    Gold, Michael R.
    HEART FAILURE CLINICS, 2011, 7 (02) : 241 - +
  • [8] Statins Reduce Appropriate Cardioverter-Defibrillator Shocks and Mortality in Patients With Failure and Combined Heart Cardiac Resynchronization and Implantable Cardioverter-Defibrillator Therapy
    Desai, Harit
    Aronow, Wilbert S.
    Tsai, Fausan S.
    Ahn, Chu
    Lai, Hoang M.
    Amin, Harshad
    Gandhi, Kaushang
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY AND THERAPEUTICS, 2009, 14 (03) : 176 - 179
  • [9] Diabetes Mellitus and Outcomes of Cardiac Resynchronization With Implantable Cardioverter-Defibrillator Therapy in Older Patients With Heart Failure
    Echouffo-Tcheugui, Justin B.
    Masoudi, Frederick A.
    Bao, Haikun
    Spatz, Erica S.
    Fonarow, Gregg C.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (08):
  • [10] Cardiac resynchronization therapy in combination with implantable cardioverter-defibrillator
    Daubert, J. Claude
    Leclercq, Christophe
    Mabo, Philippe
    EUROPACE, 2009, 11 : 87 - 92