Effect of hyperthermal cryogenic environments on the performance of piezoelectric transducer

被引:16
|
作者
Wang, Tongzhao [1 ]
Quan, Qiquan [1 ]
Tang, Dewei [1 ]
Yang, Zheng [1 ]
Huang, Jiangchuan [2 ]
Guo, Fan [3 ]
Meng, Linzhi [3 ]
Zhao, Zhijun [3 ]
Deng, Zongquan [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
[2] China Acad Space Technol, Beijing 100094, Peoples R China
[3] Beijing Inst Spacecraft Syst Engn, Beijing 100094, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasonic drill; Hyperthermal and cryogenic; Resonant characteristics; Single crystal piezoelectric rings; Asteroid exploration; ULTRASONIC MOTOR; PREDICTION; DRILL;
D O I
10.1016/j.applthermaleng.2021.116725
中图分类号
O414.1 [热力学];
学科分类号
摘要
China's asteroid exploration mission plans to use multiple ultrasonic drill cross-drilling to anchor the spacecraft on the asteroid surface. To solve the problem of the environmental temperature adaptability of the ultrasonic drill on the surface of asteroids, we propose an ultrasonic drill driven by the Single crystal piezoelectric rings piezoelectric transducer and studied the resonant characteristics of the piezoelectric transducer at hyperthermal and cryogenic environments. First, the ultrasonic drill's structure and working principle are proposed along with the detailed design of the transducer. Then, the theoretical analysis and finite element method were used to establish the frequency-temperature model of the transducer, respectively. It can be simulated the effect of temperature on the resonant frequency and the nodal plane offset of the transducer. Finally, experiments were conducted to verify the change law of the resonant frequency of the transducer, and tested the drilling performance of the ultrasonic drill in hyperthermal and cryogenic. Our results showed that the transducer's resonant frequency decreases with the increase of temperature, which is approximately linear; the ultrasonic drill can maintain good drilling performance in the temperature range of -175 to 100 degrees C. Meanwhile, the drilling pressure is only 5 N, and the drilling power is less than 40 W. This article fills the research gap in the resonant performance of ultrasonic drill in hyperthermal and cryogenic environments, and provides a technical reference for the application of ultrasonic drill in extraterrestrial environments.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] TRANSIENT PERFORMANCE OF A PIEZOELECTRIC TRANSDUCER
    REDWOOD, M
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1961, 33 (04): : 527 - +
  • [2] Performance of smart piezoelectric transducers for structural health monitoring on composite laminates in cryogenic environments
    Tseng, KK
    Tinker, ML
    Lassiter, JO
    Wang, LS
    SMART STRUCTURES AND MATERIALS 2004: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS, 2004, 5391 : 636 - 643
  • [3] ELECTRONICALLY SCANNED MULTICHANNEL PRESSURE TRANSDUCER SYSTEM FOR CRYOGENIC ENVIRONMENTS
    CHAPMAN, JJ
    CRYOGENICS, 1990, 30 (12) : 1104 - 1108
  • [4] MEDICAL PIEZOELECTRIC ULTRASONIC TRANSDUCER AND THEIR PERFORMANCE ANALYSES
    Yang, Lin-zhi
    Li, Quan-lu
    Ji, Yang-hong
    Geng, Jie
    Wang, Sheng-li
    Cai, Chun-fang
    PROCEEDINGS OF THE 2008 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS, 2008, : 488 - +
  • [5] Optimization of the performance of the sandwich piezoelectric ultrasonic transducer
    Lin, SY
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (01): : 182 - 186
  • [6] Effects of heat acclimation on individual safety performance in hyperthermal indoor environments
    Chong, Daokun
    Zhu, Neng
    Luo, Wei
    Zhang, Zhiyu
    Pan, Xiaodi
    BUILDING AND ENVIRONMENT, 2020, 168
  • [7] MICROBIAL LIFE IN HYPERTHERMAL ENVIRONMENTS
    STETTER, KO
    ASM NEWS, 1995, 61 (06): : 285 - 290
  • [8] Minimizing RF Performance Spikes in a Cryogenic Orthomode Transducer (OMT)
    Henke, Doug
    Claude, Stephane
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (04) : 840 - 850
  • [9] PIEZOELECTRIC DISPLACEMENT TRANSDUCER FOR FINE MOVEMENT AND ITS PERFORMANCE
    BINDAL, VN
    CHANDRA, M
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1977, 15 (02) : 109 - 114
  • [10] INVESTIGATION OF PIEZOELECTRIC TRANSDUCER PERFORMANCE AT HIGH ELECTRIC DRIVES
    BINDAL, VN
    SAKSENA, TK
    JAIN, SK
    GUPTA, R
    ACUSTICA, 1994, 80 (01): : 90 - 92