Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

被引:4
|
作者
Nakamura, T. [1 ]
Wada, H. [1 ]
Asaji, T. [2 ]
Furuse, M. [1 ]
机构
[1] Oshima Coll, Natl Inst Technol, 1091-1 Komatsu, Yamaguchi 7422193, Japan
[2] Toyama Coll, Natl Inst Technol, 13 Hongo, Toyama 9398630, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 02期
关键词
D O I
10.1063/1.4937012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar4+ ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Emittance studies of the 2.45 GHz permanent magnet ECR ion source
    Zelenak, A
    Bogomolov, SL
    Yazvitsky, NY
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1653 - 1655
  • [2] Magnetic Field Design for a 2.45-GHz ECR Ion Source with Permanent Magnets
    Park, J. Y.
    Lee, H. S.
    Won, M. S.
    Lee, B. S.
    Kim, J. P.
    Yoon, J. H.
    Bae, J. S.
    Bang, J. K.
    Ahn, J. K.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (02) : 409 - 414
  • [3] 2.45 GHz single charge state ECR ion source with permanent magnet
    Ding, J.Z.
    Zhao, Y.B.
    Liu, Z.W.
    Zhao, H.W.
    Yuan, P.
    Cao, Y.
    Lei, H.L.
    Zhang, Z.M.
    Zhang, X.Z.
    Zhang, W.
    Guo, X.H.
    Wang, H.
    Feng, Y.C.
    Li, J.Y.
    Ma, B.H.
    Gao, J.Y.
    Song, P.
    Li, X.X.
    He Jishu/Nuclear Techniques, 2001, 24 (01):
  • [4] Studies on the effect of the axial magnetic field on the x-ray bremsstrahlung in a 2.45 GHz permanent magnet microwave ion source
    Kumar, Narender
    Rodrigues, G.
    Lakshmy, P. S.
    Baskaran, R.
    Mathur, Y.
    Ahuja, R.
    Kanjilal, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [5] Electron temperature Profiles in Axial Field 2.45 GHz ECR Ion Source with a Ceramic Chamber
    Abe, K.
    Tamura, R.
    Kasuya, T.
    Wada, M.
    FIFTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2016), 2017, 1869
  • [6] A compact 2.45 GHz ECR ion source with permanent magnets for material science
    Tojyo, E
    Katayama, I
    Jeong, SC
    Oyaizu, M
    Ishiyama, H
    Kawakami, H
    Enomoto, K
    Miyatake, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 586 - 588
  • [7] A miniaturized 2.45 GHz ECR ion source at Peking University
    温佳美
    彭士香
    任海涛
    张滔
    张景丰
    武文斌
    孙江
    郭之虞
    陈佳洱
    Chinese Physics B, 2018, (05) : 378 - 381
  • [8] A miniaturized 2.45 GHz ECR ion source at Peking University*
    Wen, Jia-Mei
    Peng, Shi-Xiang
    Ren, Hai-Tao
    Zhang, Tao
    Zhang, Jing-Feng
    Wu, Wen-Bin
    Sun, Jiang
    Guo, Zhi-Yu
    Chen, Jia-Er
    CHINESE PHYSICS B, 2018, 27 (05)
  • [9] DEVELOPMENT OF A COMPACT 2.45 GHZ ECR ION-SOURCE
    FIEDLER, S
    WINTER, HP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2532 - 2534
  • [10] Sufficient cusp field generated by permanent magnet for compact ECR ion source
    Rashid, MH
    Bhandari, RK