Copper(II) ion selective PVC membrane electrode based on S,S′-bis(2-aminophenyl)ethanebis(thioate)

被引:0
|
作者
Buzuk, Marijo [1 ]
Brinic, Slobodan [1 ]
Generalic, Eni [1 ]
Bralic, Marija [1 ]
机构
[1] Univ Split, Fac Chem & Technol, Dept Gen & Inorgan Chem, Split 21000, Croatia
关键词
copper(II); ISE; S; '-bis(2-aminophenyl)ethanebis(thioate); polymer membrane electrodes; potentiometry; NEUTRAL IONOPHORE; BULK OPTODES; SENSORS; CARRIER; MATRIX;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
S,S'-bis(2-aminophenyl)ethanebis(thioate) (APhET) was synthesized and used as ion carrier in the preparation of copper(II) ion selective PVC membrane electrodes. The best performances were obtained by a membrane electrode with the composition: PVC as matrix (66 mg), APhET as ionophore (4 mg), o-NPOE as plasticizer (132 mg) and NaTBP as anionic additive (1/2 mole ratio in respect to APhET). This electrode exhibited a linear potential response to copper(II) in the concentration range 6.0 x 10(-6) - 5.0 x 10(-2) mol dm(-3), with Nernstian slope of 29.5 mV/decade and detection limit down to 4 x 10(-6) mol dm(-3). It is suitable for copper(II) determination within pH between 4 and 7, and performs well over a period of 3 months. The electrode is selective for copper over a large number of metal ions, except Hg2+. No interference was noticed by chlorides and other examined anions. Described membrane electrode can be used in analytical measurements by direct potentiometry as well in potentiometric titration.
引用
收藏
页码:801 / 806
页数:6
相关论文
共 50 条
  • [1] Zn(II)-selective membrane electrode based on tetra(2-aminophenyl) porphyrin
    Fakhari, AR
    Shamsipur, M
    Ghanbari, K
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 177 - 183
  • [2] Extraction and spectrophotometric determination of copper(II) with S,S′-bis(2-aminophenyl)oxalate
    Nohut, S
    Karaböcek, S
    Güner, S
    Gök, Y
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) : 309 - 314
  • [3] Copper Ion Selective Membrane Electrode Based on Bis(salphenH2) Derivatives
    Lee, Chaegyung
    Kim, Dong Wan
    Kim, Junghwan
    Yang, Mi-Hyi
    Choi, Myong Yong
    Kim, Jae Sang
    SENSOR LETTERS, 2010, 8 (02) : 297 - 302
  • [4] Improving the Response of Copper(II) Selective PVC Membrane Electrode by Modification of N2S2 Donor Ligand
    Brinic, Slobodan
    Buzuk, Marijo
    Generalic, Eni
    Bralic, Marija
    ACTA CHIMICA SLOVENICA, 2010, 57 (02) : 318 - 324
  • [5] Development of a new copper(II) ion-selective PVC membrane electrode based on tris(2-benzimidazolylmethyl)amine
    Tomar, Praveen Kumar
    Chandra, Sulekh
    Singh, Inderjeet
    Kumar, Avdhesh
    Malik, Amrita
    Singh, Arendra
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (11) : 1739 - 1744
  • [6] A selective membrane electrode for salicylate ion based on a bis-salicylaldoxime complex of copper(II) as ionophore
    Wang Fuchang
    Chai Yaqin
    Yuan Ruo
    Gui Guofeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 725 - 728
  • [7] A PVC MATRIX MEMBRANE COPPER ION-SELECTIVE ELECTRODE BASED ON A MACROCYCLIC POLYTHIAETHER
    KAMATA, S
    HIGO, M
    KAMIBEPPU, T
    TANAKA, I
    CHEMISTRY LETTERS, 1982, (03) : 287 - 288
  • [8] ION-SELECTIVE MEMBRANE ELECTRODE FOR COPPER (II)
    PICK, J
    KEMIAI KOZLEMENYEK, 1973, 39 (01): : 19 - 33
  • [9] PREPARATION AND CHARACTERIZATION ION SELECTIVE ELECTRODE Cd(II) BASED ON CHITOSAN IN PVC MEMBRANE
    Panggabean, A. Sentosa
    INDONESIAN JOURNAL OF CHEMISTRY, 2011, 11 (03) : 285 - 289
  • [10] A selective membrane electrode for thiocyanate ion based on a bis-taurine-salicylic binuclear copper(II) complex as ionophore
    Wang, FC
    Chai, YQ
    Yuan, R
    Chen, CH
    Dai, JY
    Xu, L