Sequential sandwich immunoassay for simultaneous detection in trace samples using single-channel surface plasmon resonance

被引:1
|
作者
Xia, Yinqiang [1 ]
Zhang, Peiqian [1 ]
Yuan, Hui [1 ]
Su, Rongxin [1 ,2 ]
Huang, Renliang [3 ]
Qi, Wei [1 ,2 ]
He, Zhimin [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, Tianjin Key Lab Membrane Sci & Desalinat Technol, State Key Lab Chem Engn, Tianjin 300072, Peoples R China
[2] Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
HYALURONIC-ACID; SPR BIOSENSOR; SENSORS; ASSAY;
D O I
10.1039/c9an01183h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To analyze multiple analytes in trace samples, low-dosage and high efficiency are crucial in many common cases. Herein, we developed a facile method using a single-channel surface plasmon resonance (SPR)-based biosensor for the simultaneous detection of gentamicin (GEN) and melamine (MEL) in milk and serum with only one sample injection. Based on a sandwich immunoassay, non-interfering antibodies against GEN from mouse (AbGEN) and against MEL from rabbit (AbMEL) were chosen to capture the analytes. Secondary antibodies against mouse (AbM) and rabbit (AbR) were used to bind with AbGEN and AbMEL to determine the concentrations of GEN and MEL on a single channel of an SPR sensor. All of the detection process could be done in 10 min with 50 mu L of sample injection. According to the response shifts of AbM and AbR, two standard curves for GEN and MEL were obtained successively, with the limit of detection (LOD) values at 4.4 ng mL(-1) and 1.3 ng mL(-1), respectively. Moreover, the feasibility was determined by spiking milk and serum samples with GEN and MEL, with recoveries in the range of 81.6%-118.0%. Importantly, the analytes can be substituted by others for much more applications. This method is also expected to multiply the detection efficiency of multi-channel SPR biosensors with low-dosage samples in the future.
引用
收藏
页码:5700 / 5705
页数:6
相关论文
共 50 条
  • [1] Detection of fungal spores using a generic surface plasmon resonance immunoassay
    Skottrup, Peter
    Hearty, Stephen
    Frokiaer, Hanne
    Leonard, Paul
    Hejgaard, Jorn
    O'Kennedy, Richard
    Nicolaisen, Mogens
    Justesen, Annemarie F.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2724 - 2729
  • [2] A single molecule immunoassay by localized surface plasmon resonance
    Mayer, Kathryn M.
    Hao, Feng
    Lee, Seunghyun
    Nordlander, Peter
    Hafner, Jason H.
    NANOTECHNOLOGY, 2010, 21 (25) : 255503
  • [3] Design of elution strategy for simultaneous detection of chloramphenicol and gentamicin in complex samples using surface plasmon resonance
    Xia, Yinqiang
    Su, Rongxin
    Huang, Renliang
    Ding, Li
    Wang, Libing
    Qi, Wei
    He, Zhimin
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 266 - 272
  • [4] Indirect competitive immunoassay for the detection of fungicide Thiabendazole in whole orange samples by Surface Plasmon Resonance
    Estevez, M. -Carmen
    Belenguer, Jose
    Gomez-Montes, Silvia
    Miralles, Javier
    Escuela, Alfonso M.
    Montoya, Angel
    Lechuga, Laura M.
    ANALYST, 2012, 137 (23) : 5659 - 5665
  • [5] Modeling of Detection Limit for Competitive Immunoassay Using Surface Plasmon Resonance Sensor
    Naruse, Masahiro
    Morishita, Masahiro
    Onodera, Takeshi
    Toko, Kiyoshi
    Hayashi, Yuzuru
    SENSORS AND MATERIALS, 2016, 28 (03) : 219 - 229
  • [6] Rapid detection of nivalenol and deoxynivalenol in wheat using surface plasmon resonance immunoassay
    Kadota, Tomoyuki
    Takezawa, Yoko
    Hirano, Satoshi
    Tajima, Osamu
    Maragos, Chris M.
    Nakajima, Takashi
    Tanaka, Toshitsugu
    Kamata, Yoichi
    Sugita-Konishi, Yoshiko
    ANALYTICA CHIMICA ACTA, 2010, 673 (02) : 173 - 178
  • [7] The simultaneous detection of free and total prostate antigen in serum samples with high sensitivity and specificity by using the dual-channel surface plasmon resonance
    Jiang, Zhongxiu
    Qin, Yun
    Peng, Zhen
    Chen, Shenghua
    Chen, Shu
    Deng, Chunyan
    Xiang, Juan
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 268 - 273
  • [8] Simultaneous, quantitative detection of five whey proteins in multiple samples by surface plasmon resonance
    Billakanti, Jagan M.
    Fee, Conan J.
    Lane, Felicity R.
    Kash, Ali Shiweh
    Fredericks, Rayleen
    INTERNATIONAL DAIRY JOURNAL, 2010, 20 (02) : 96 - 105
  • [9] Detection of microcystins in environmental samples using surface plasmon resonance biosensor
    Hu, Chenlin
    Gan, Nanqin
    Chen, Yuanyuan
    Bi, Lijun
    Zhang, Xianen
    Song, Lirong
    TALANTA, 2009, 80 (01) : 407 - 410
  • [10] An improved immunoassay for detection of saxitoxin by surface plasmon resonance biosensors
    Yakes, Betsy Jean
    Prezioso, Samantha
    Haughey, Simon A.
    Campbell, Katrina
    Elliott, Christopher T.
    DeGrasse, Stacey L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02): : 805 - 811