Determination of sulfide in waters by flow-injection solid phase spectrophotometry

被引:70
|
作者
Cassella, RJ
Teixeira, LSG
Garrigues, S
Costa, ACS
Santelli, RE
de la Guardia, M
机构
[1] Univ Valencia, Dept Quim Analit, E-46100 Valencia, Spain
[2] CEFETEQ RJ, BR-20270021 Rio De Janeiro, Brazil
[3] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Niteroi, RJ, Brazil
[4] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
关键词
D O I
10.1039/b004008h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive flow injection solid-phase spectrophotometric method was developed for the determination of sulfide in waters. The method is based on the formation of Methylene Blue (MB) by reaction between sulfide and N,N-dimethyl-p-phenylenediamine chloride in presence of Fe(iii) in acidic medium. The MB formed was adsorbed on C-18 bonded silica, located inside a laboratory-made flow cell, which was placed in the optical path of the spectrophotometer. Analyte retention and detection at 666 nm were performed simultaneously, followed by elution with a mixture of methanol and hydrochloric acid. Several variables of the system, such as amine concentration, acidity of the reaction medium, reactor coil volume, sample volume and flow rate of the cleaning solution, were studied in order to achieve the best performance in the analysis of natural samples. This procedure provides an alternative for the determination of sulfide in the range 5-50 g L-1 with a relative standard deviation of 4.0% for 10 independent determinations at a concentration level of 50 g L-1. A detection limit of 1.7 g L-1, for a confidence level of 99.7%, was found. The system presented an analytical throughput of 12 h(-1).
引用
收藏
页码:1835 / 1838
页数:4
相关论文
共 50 条
  • [1] Determination of formaldehyde in Brazilian alcohol fuels by flow-injection solid phase spectrophotometry
    Teixeira, LSG
    Leao, ES
    Dantas, AF
    Pinheiro, HLC
    Costa, ACS
    de Andrade, JB
    TALANTA, 2004, 64 (03) : 711 - 715
  • [2] Flow-injection solid-phase spectrophotometry for the determination of zinc in pharmaceutical preparations
    Teixeira, LSG
    Rocha, FRP
    Korn, M
    Reis, BF
    Ferreira, SLC
    Costa, ACS
    ANALYTICA CHIMICA ACTA, 1999, 383 (03) : 309 - 315
  • [3] DETERMINATION OF PARAQUAT BY FLOW-INJECTION SPECTROPHOTOMETRY
    JAIN, A
    VERMA, KK
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1993, 284 (02) : 275 - 279
  • [4] DETERMINATION OF PARAQUAT BY FLOW-INJECTION SPECTROPHOTOMETRY
    GUIJARRO, EC
    YANEZSEDENO, P
    DIEZ, LMP
    ANALYTICA CHIMICA ACTA, 1987, 199 : 203 - 208
  • [5] FLOW-INJECTION METHOD FOR THE DETERMINATION OF TIN IN FRUIT JUICES USING SOLID-PHASE SPECTROPHOTOMETRY
    CAPITANVALLVEY, LF
    VALENCIA, MC
    MIRON, G
    ANALYTICA CHIMICA ACTA, 1994, 289 (03) : 365 - 370
  • [6] SELECTIVE DETERMINATION OF ARSENITE BY FLOW-INJECTION SPECTROPHOTOMETRY
    FRENZEL, W
    TITZENTHALER, F
    ELBEL, S
    TALANTA, 1994, 41 (11) : 1965 - 1971
  • [7] DETERMINATION OF CADMIUM IN FERTILIZERS BY FLOW-INJECTION SPECTROPHOTOMETRY
    NETO, JAG
    BERGAMIN, H
    ZAGATTO, EAG
    KRUG, FJ
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 439 - 445
  • [8] DETERMINATION OF MOLYBDENUM IN STEELS BY FLOW-INJECTION SPECTROPHOTOMETRY
    KRUG, FJ
    BAHIA, O
    ZAGATTO, EAG
    ANALYTICA CHIMICA ACTA, 1984, 161 (JUL) : 245 - 255
  • [9] SEQUENTIAL DETERMINATION OF NICKEL AND COPPER IN WASTE-WATERS BY REVERSED FLOW-INJECTION SPECTROPHOTOMETRY
    WANG, P
    SHI, SJ
    ZHOU, D
    MICROCHEMICAL JOURNAL, 1995, 52 (02) : 146 - 154
  • [10] Nickel and zinc determination by flow-injection solid-phase spectrophotometry exploiting different sorption rates
    Teixeira, LSG
    Rocha, FRP
    Korn, M
    Reis, BF
    Ferreira, SLC
    Costa, ACS
    TALANTA, 2000, 51 (05) : 1027 - 1033