Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: Four-Year Clinical Results

被引:0
|
作者
Roediger, Matthias [1 ]
Gersdorff, Nikolaus [1 ]
Huels, Alfons [1 ]
Rinke, Sven
机构
[1] Univ Gottingen, Dept Prosthodont, D-37075 Gottingen, Germany
关键词
COMPLICATION RATES; OBSERVATION PERIOD; DENTAL PROSTHESES; SURVIVAL; FPDS; METAANALYSIS; FRAMEWORKS; CROWNS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In this prospective clinical study, the performance of three- and four-unit fixed partial dentures (FPDs) with frameworks fabricated of yttria partially stabilized zirconia was determined after a mean observation period of 50 months. The study focused on the survival of the restoration (in situ criterion) and the success of the ceramic veneers (no defect). Materials and Methods: Seventy-five patients with a maximum of two missing teeth and an antagonistic dentition were treated at the Department of Prosthodontics, University of Goettigen, with 99 posterior FPDs. Fifty-one specimens (experimental group) were veneered with an experimental ceramic suitable for titanium and zirconia frameworks (thermal expansion coefficient [TEC]: 8.5 mu m/m(star)K); 48 restorations (Ceram-S group) were veneered with a commercially available low-fusing ceramic optimized for zirconia frameworks (TEC: 9.5 pm/m(star)K). All restorations were luted with zinc-phosphate cement. Statistical analysis was performed according to the Kaplan-Meier method; time-dependent success rates of the different types of ceramic veneers were analyzed using the log-rank test. Results: Seven restorations were lost: 4 due to technical complications and 3 due to biologic complications. The overall survival rate after 48 months was 94% (Kaplan-Meier analysis). Twenty-three events required clinical intervention for restoration maintenance: 13 ceramic veneer chippings (polishing), 6 losses of retention (recementation), 3 caries lesions (filling therapy), and 1 loss of vitality (endodontic treatment). Between the two groups of veneering materials, no significant difference in the probability for success was determined (log-rank test, P = .81). Conclusions: Within a mean observation period of 4 years, sufficient survival rates for zirconia-based posterior FPDs could be verified. The main complications included fracture of the ceramic veneering material and decementation, which occurred mainly in the mandible. Int J Prosthodont 2010;23:141-148.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [1] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results
    Rinke, Sven
    Gersdorff, Nikolaus
    Lange, Katharina
    Roediger, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 164 - 171
  • [2] Zirconia Posterior Fixed Partial Dentures: 5-Year Clinical Results of a Prospective Clinical Trial
    Schmitt, Johannes
    Goellner, Matthias
    Lohbauer, Ulrich
    Wichmann, Manfred
    Reich, Sven
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (06) : 585 - 589
  • [3] Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
    Sailer, Irena
    Feher, Aurel
    Filser, Frank
    Gauckler, Ludwig J.
    Luethy, Heinz
    Hammerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (04) : 383 - 388
  • [4] A Four-Year Prospective Clinical Evaluation of Zirconia and Metal-Ceramic Posterior Fixed Dental Prostheses
    Pelaez, Jesus
    Cogolludo, Pablo G.
    Serrano, Benjamin
    Lozano, Jose F. L.
    Suarez, Maria J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (05) : 451 - 458
  • [5] Zirconia Posterior Fixed Partial Dentures: A Prospective Clinical 3-year Follow-up
    Schmitt, Johannes
    Holst, Stefan
    Wichmann, Manfred
    Reich, Sven
    Goellner, Matthias
    Hamel, Joerg
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (06) : 597 - 603
  • [6] Ten-year clinical performance of zirconia posterior fixed partial dentures
    Matta, Ragai-Edward
    Eitner, Stephan
    Stelzer, Simon Paul
    Reich, Sven
    Wichmann, Manfred
    Berger, Lara
    JOURNAL OF ORAL REHABILITATION, 2022, 49 (01) : 71 - 80
  • [7] Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures
    Esquivel-Upshaw, Josephine F.
    Young, Henry
    Jones, Jack
    Yang, Mark
    Anusavice, Kenneth J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (02) : 155 - 160
  • [8] Prospective clinical study of zirconia posterior fixed partial dentures:: 3-year follow-up
    Sailer, Irena
    Feher, Aurel
    Filser, Frank
    Luethy, Heinz
    Gauckler, Ludwig J.
    Schaerer, Peter
    Haemmerie, Christoph Hans Franz
    QUINTESSENCE INTERNATIONAL, 2006, 37 (09): : 685 - 693
  • [9] 3-year clinical results of zirconia posterior fixed partial dentures made Direct Ceramic Machining (DCM).
    Sailer, I.
    Luethy, H.
    Feher, A.
    Schumacher, M.
    Schaerer, P.
    Hammerle, C. H. F.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B21 - B21
  • [10] Prospective Evaluation of Posterior Fixed Zirconia Dental Prostheses: 10-Year Clinical Results
    Rinke, Sven
    Wehle, Jens
    Schulz, Xenia
    Bruegers, Ralf
    Roediger, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (01) : 35 - 42