Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

被引:26
|
作者
Ozarslan, Mehmet Mustafa [1 ]
Buyukkaplan, Ulviye Sebnem [1 ]
Barutcigil, Cagatay [2 ]
Arslan, Merve [1 ]
Turker, Nurullah [1 ]
Barutcigil, Kubilay [1 ]
机构
[1] Akdeniz Univ, Dept Prosthodont, Fac Dent, TR-07058 Antalya, Turkey
[2] Akdeniz Univ, Dept Restorat Dent, Fac Dent, TR-07058 Antalya, Turkey
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2016年 / 8卷 / 01期
关键词
PICN; VITA Enamic; Finishing and polishing; Surface roughness; Spectrophotometer; IN-VITRO; DENTAL CERAMICS; PORCELAIN; WEAR;
D O I
10.4047/jap.2016.8.1.16
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions 2 x 10 x 12 mm from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at alpha=0.05. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding Delta E-00 was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (Delta E-00<2.25) except Clinical Kit Groups (Delta E-00>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [1] EFFECTS OF SURFACE-FINISHING PROTOCOLS ON THE ROUGHNESS, COLOR CHANGE, AND TRANSLUCENCY OF DIFFERENT CERAMIC SYSTEMS
    Akar, Gulcan Coskun
    Pekkan, Gurel
    Cal, Ebru
    Eskitascioglu, Gurcan
    Ozcan, Mutlu
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 314 - 321
  • [2] The Effect of Different Surface Finishing Procedures on Surface Roughness and Fracture Toughness in All-Ceramic Restorations
    Yondem, Isa
    Inan, Ozgur
    INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2011, 8 (02) : 437 - 445
  • [3] Effects of Different Finishing Procedures on Surface Roughness of Hybrid CAD/CAM Materials
    Akan, Ender
    Colgecen, Ozlem
    Mese, Ibrahim T.
    Bagis, Bora
    JOURNAL OF DENTISTRY INDONESIA, 2021, 28 (03) : 185 - 191
  • [4] Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic
    Capelozza Boaventura, Juliana Maria
    Nishida, Rodrigo
    Elossais, Andre Afif
    Lima, Darlon Martins
    Santos Nunes Reis, Jose Mauricio
    Campos, Edson Alves
    de Andrade, Marcelo Ferrarezi
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (3-4) : 438 - 443
  • [5] Influence of Different Finishing-Polishing Procedures and Thermocycle Aging on the Surface Roughness of Nano-Ceramic Hybrid CAD/CAM Material
    Ozer, N. E.
    Oguz, E., I
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (05) : 604 - 611
  • [6] Bond strength between composite repair and polymer-infiltrated ceramic-network material: Effect of different surface treatments
    Dal Bello, Yuri
    Di Domenico, Marielle B.
    Dal Magro, Leticia
    Lise, Monica W.
    Corazza, Pedro H.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (03) : 275 - 279
  • [7] Effect of resin cement viscosities and surface roughness on shear bond strength of conditioned polymer infiltrated ceramic network
    Alzahrani, Khaled M.
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 49
  • [8] Evaluation of the effects of finishing and polishing systems on ceramic surface roughness.
    Bottino, M. C.
    Valandro, L. F.
    Kantorski, K. Z.
    Scotti, R.
    Bottino, M. A.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B133 - B133
  • [9] Superficial Effects of Different Finishing and Polishing Systems on the Surface Roughness and Color Change of Resin-Based CAD/CAM Blocks
    Aydin, Numan
    Karaoglanoglu, Serpil
    Oktay, Elif Aybala
    Ersoz, Bilge
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (03) : 87 - 97
  • [10] Effect of finishing methods on surface roughness and color stability in all-ceramic systems
    Yondem, Isa
    Secilmis, Asli
    Inan, Ozgur
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2011, 357 (6-7) : 1499 - 1503