Processing of low-intensity CCD for temperature mapping in industrial processes

被引:0
|
作者
Zauner, G [1 ]
Heim, D [1 ]
Niel, K [1 ]
Hendorfer, G [1 ]
Stoeri, H [1 ]
机构
[1] Univ Appl Sci Upper Austria, Coll Engn, Fachhsch Wels Automat Engn, A-4600 Wels, Austria
关键词
thermal imaging; temperature mapping; image processing; image denoising; CCD camera characterisation; platelet-filtering;
D O I
10.1117/12.545372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The temperature-mapping system presented is based on a grayscale CCD camera, rotating near infrared filters and an image processing software which is used for thermal imaging of heated metal parts in heat treatment processes (plasma nitriding). Due to relatively low process temperatures of about 300 degreesC - 500 degreesC the received light intensity of the glowing metal parts is very weak. The quality of these images can be improved by applying modern image processing filter methods. A precondition for a correct application of these denoising filters is an exact noise characterisation of the imaging system. A camera characterisation procedure based on the photon transfer technique and the system transfer function is presented. Based on these results, examples for density and intensity estimations of Poisson noise images with multiresolution methods (Platelets) are presented. The results are used to improve image quality and measurement accuracy of CCD based thermal images.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [1] CALCULATION OF RELAXATION PROCESSES OF A PHOTOTRIODE FOR LOW-INTENSITY ILLUMINATION
    POTEKHINA, ND
    SOVIET PHYSICS-SOLID STATE, 1960, 1 (10): : 1383 - 1388
  • [2] EL SALVADORS NEGOTIATED TRANSITION - LOW-INTENSITY CONFLICT TO LOW-INTENSITY DEMOCRACY LOW-INTENSITY DEMOCRACY
    STAHLERSHOLK, R
    JOURNAL OF INTERAMERICAN STUDIES AND WORLD AFFAIRS, 1994, 36 (04): : 1 - 59
  • [3] Noninvasive neuromodulation and thalamic mapping with low-intensity focused ultrasound
    Dallapiazza, Robert F.
    Timbie, Kelsie F.
    Holmberg, Stephen
    Gatesman, Jeremy
    Lopes, M. Beatriz
    Price, Richard J.
    Miller, G. Wilson
    Elias, W. Jeffrey
    JOURNAL OF NEUROSURGERY, 2018, 128 (03) : 875 - 884
  • [4] Low-intensity surveillance
    Greblo, Edoardo
    AUT AUT, 2008, (340): : 14 - 36
  • [5] LOW-INTENSITY CONFLICT
    HERMAN, PF
    ORBIS-A JOURNAL OF WORLD AFFAIRS, 1990, 34 (03): : 431 - 435
  • [6] The effects on the tissue temperature distribution of low-intensity laser irradiation
    Wang, XJ
    Zeng, CC
    Liu, SH
    Liu, LG
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 780 - 788
  • [7] Effects of low-intensity Ultrahigh frequency electromagnetic radiation on inflammatory processes
    Lushnikov, KV
    Shumilina, YV
    Yakushina, VS
    Gapeev, AB
    Sadovnikov, VB
    Chemeris, NK
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2004, 137 (04) : 364 - +
  • [8] Effects of Low-Intensity Ultrahigh Frequency Electromagnetic Radiation on Inflammatory Processes
    K. V. Lushnikov
    Yu. V. Shumilina
    V. S. Yakushina
    A. B. Gapeev
    V. B. Sadovnikov
    N. K. Chemeris
    Bulletin of Experimental Biology and Medicine, 2004, 137 : 364 - 366
  • [9] Neuroelectric Indices of Attentional Processing are Reduced During Low-Intensity Cycling
    Carmichael, Kaitlyn E.
    Cleveland, David J.
    Vigil, Alyssa G.
    Ruhland, Megan E.
    Olson, Ryan L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 553 - 553
  • [10] EFFECT OF LOW-INTENSITY LUMINESCENCE ON REPARATIVE PROCESSES IN SKIN WOUNDS IN THE RAT
    MONICH, VA
    SHAKHOV, BE
    VOROBEV, AV
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1994, 117 (06) : 674 - 675