An integrated laser blood flowmeter

被引:47
|
作者
Higurashi, E [1 ]
Sawada, R [1 ]
Ito, T [1 ]
机构
[1] NTT Microsyst Integrat Labs, Kanagawa 2430198, Japan
关键词
blood flow; integrated optics; optical sensor; silicon micromachining; wearable sensor;
D O I
10.1109/JLT.2003.809551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have constructed a very small and lightweight blood flowmeter using micromachining and surface mounting techniques for a wearable health monitoring system. The hybrid integrated structure of the optical system incorporates a InGaAsP-InP distributed feedback laser diode (DFB-LD) with a wavelength of 1310 nm, an edge-illuminated photodiode (PD) and a polyimide waveguide on silicon substrate (2 min x 3 mm). This integrated flowmeter can be positioned directly on the tissue and permits real-time monitoring of capillary microcirculation. In-vivo measurements of blood perfusion in a finger confirm the feasibility of the blood flowmeter.
引用
收藏
页码:591 / 595
页数:5
相关论文
共 50 条
  • [1] Integrated micro blood flowmeter
    Higurashi, Eiji
    Sawada, Renshi
    Ito, Takahiro
    NTT R and D, 2002, 51 (05): : 28 - 32
  • [2] Integrated laser Doppler blood flowmeter combining optical contact force
    Nogami, Hirofumi
    Komatsutani, Kosuke
    Hirata, Tomoki
    Sawada, Renshi
    2019 INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING (ICEP 2019), 2019, : 287 - 290
  • [3] Integrated Laser Doppler Blood Flowmeter Designed to Enable Wafer-Level Packaging
    Kimura, Yoshinori
    Goma, Masaki
    Onoe, Atsushi
    Higurashi, Eiji
    Sawada, Renshi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (08) : 2026 - 2033
  • [4] Low-power Consumption Integrated Laser Doppler Blood Flowmeter with a Built-in Silicon Microlens
    Kimura, Yoshinori
    Onoe, Atsushi
    Higurashi, Eiji
    Sawada, Renshi
    2008 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2008, : 13 - +
  • [5] EVALUATION OF AN INFRARED LASER-DOPPLER BLOOD FLOWMETER
    SHEPHERD, AP
    RIEDEL, GL
    KIEL, JW
    HAUMSCHILD, DJ
    MAXWELL, LC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : G832 - G839
  • [6] Evaluation of a new laser Doppler retinal blood flowmeter
    Feke, GT
    Ishiko, S
    McMeel, JW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S487 - S487
  • [7] Wearable laser blood flowmeter for ubiquitous healthcare service
    Kiyokura, T.
    Tatara, N.
    Shimada, J.
    Haga, T.
    2007 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2007, : 4 - 5
  • [8] MICROPOWER INTEGRATED-CIRCUITS FOR AN IMPLANTABLE BIDIRECTIONAL BLOOD FLOWMETER
    FRESCURA, BL
    MEINDL, JD
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1976, 11 (06) : 817 - 825
  • [9] A novel laser Doppler flowmeter for pulpal blood flow measurements
    Zang, DY
    Millerd, JE
    WilderSmith, PBB
    Arrastia, AMA
    LASERS IN DENTISTRY II, PROCEEDINGS OF, 1996, 2672 : 21 - 26
  • [10] The use of a laser Doppier flowmeter to measure rectal blood flow
    M. J. O’Sullivan
    D. C. Winter
    A. E. Brannigan
    J. Deasy
    Irish Journal of Medical Science, 2002, 171 (Suppl 2)