Electrochemical sensor for endocrine disruptor bisphenol A based on a glassy carbon electrode modified with silica and nanocomposite prepared from reduced graphene oxide and gold nanoparticles

被引:29
|
作者
Liu, Enli [1 ]
Zhang, Xiaoli [1 ]
机构
[1] Shandong Univ, Sch Chem & Chem Engn, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
LIQUID-CHROMATOGRAPHY; GLUCOSE BIOSENSOR; HUMAN EXPOSURE; RIVER WATER; COMPOSITE; FILM; PHTHALOCYANINE; POLYCARBONATE; SPECTROMETRY; MILK;
D O I
10.1039/c4ay01714e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on silica and nanocomposite prepared from reduced graphene oxide and gold nanoparticles (SiO2/rGO-AuNPs), a novel and sensitive electrochemical sensor for bisphenol A (BPA) was fabricated. The electrochemical behavior of BPA on a SiO2/rGO-AuNP nanocomposite was investigated by cyclic voltammetry. Compared with bare GCE, the SiO2/rGO-AuNPs/GCE electrochemical sensor obviously reduced the oxidation overpotential of BPA and greatly enhanced the peak current. The direct detection of BPA was accomplished by using differential pulse voltammetry (DPV) under optimized conditions. A linear voltammetric response to BPA within the concentration range of 3.0 x 10(-8) to 1.0 x 10(-5) mol L-1 and 1.0 x 10(-5) to 1.2 x 10(-4) mol L-1 with a low detection limit of 5.0 x 10(-9) mol L-1 (S/N = 3) was obtained. In addition, the fabricated sensor was successfully applied to detect BPA in thermal paper samples, and the results were satisfactory.
引用
收藏
页码:8604 / 8612
页数:9
相关论文
共 50 条
  • [1] Reduced graphene oxide/gold nanoparticles nanocomposite-modified glassy carbon electrode for determination of endocrine disruptor methylparaben
    Piovesan, Jamille V.
    Santana, Edson R.
    Spinelli, Almir
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 163 - 170
  • [2] Reduced Graphene Oxide/Carbon Nanotube/Gold Nanoparticles Nanocomposite Functionalized Screen-Printed Electrode for Sensitive Electrochemical Detection of Endocrine Disruptor Bisphenol A
    Wang, Yi-Cheng
    Cokeliler, Dilek
    Gunasekaran, Sundaram
    ELECTROANALYSIS, 2015, 27 (11) : 2527 - 2536
  • [3] Development of an electrochemical sensor of endocrine disruptor bisphenol A by reduced graphene oxide for incorporation of spherical carbon nanoparticles
    Canevari, Thiago C.
    Rossi, Maura, V
    Alexiou, Anamaria D. P.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 832 : 24 - 30
  • [4] Electrochemical Dopamine Sensor Based on Gold Nanoparticles Electrodeposited on a Polymer/Reduced Graphene Oxide-Modified Glassy Carbon Electrode
    Guler, Muhammet
    Kavak, Emrah
    Kivrak, Arif
    ANALYTICAL LETTERS, 2022, 55 (07) : 1131 - 1148
  • [5] A novel electrochemical sensor of bisphenol A based on stacked graphene nanofibers/gold nanoparticles composite modified glassy carbon electrode
    Niu, Xiuli
    Yang, Wu
    Wang, Guoying
    Ren, Jie
    Guo, Hao
    Gao, Jinzhang
    ELECTROCHIMICA ACTA, 2013, 98 : 167 - 175
  • [6] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Jafari, Marzieh
    Tashkhourian, Javad
    Absalan, Ghodratollah
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1253 - 1262
  • [7] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Marzieh Jafari
    Javad Tashkhourian
    Ghodratollah Absalan
    Journal of the Iranian Chemical Society, 2017, 14 : 1253 - 1262
  • [8] Ultrasensitive DNA sensor based on gold nanoparticles/reduced graphene oxide/glassy carbon electrode
    Benyidi, Ali
    Firouzabadi, Afsaneh Dehghani
    Moshtaghiun, Seyed Mohammad
    Mazloum-Ardakani, Mohammad
    Tezerjani, Marzieh Dehghan
    ANALYTICAL BIOCHEMISTRY, 2015, 484 : 24 - 30
  • [9] Electrochemical Determination of Bisphenol A on a Glassy Carbon Electrode Modified with Gold Nanoparticles Loaded on Reduced Graphene Oxide-Multi-Walled Carbon Nanotubes Composite
    Yu Hao
    Feng Xiao
    Chen Xiao-Xia
    Qiao Jin-Li
    Gao Xiao-Ling
    Xu Na
    Gao Lou-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (05) : 713 - 720
  • [10] Dopamine and uric acid electrochemical sensor based on a glassy carbon electrode modified with cubic Pd and reduced graphene oxide nanocomposite
    Wang, Jin
    Yang, Beibei
    Zhong, Jiatai
    Yan, Bo
    Zhang, Ke
    Zhai, Chunyang
    Shiraishi, Yukihide
    Du, Yukou
    Yang, Ping
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 497 : 172 - 180