Optical coherence tomography using physical domain data compression to achieve MHz A-scan rates

被引:6
|
作者
Stroud, Jasper R. [1 ]
Liu, Luoluo [1 ]
Chin, Sang [1 ,2 ]
Tran, Trac D. [1 ]
Foster, Mark A. [1 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[2] Boston Univ, Dept Comp Sci, Boston, MA 02215 USA
来源
OPTICS EXPRESS | 2019年 / 27卷 / 25期
基金
美国国家科学基金会;
关键词
OCT; RECONSTRUCTION; PRINCIPLES; RECOVERY; FLOW;
D O I
10.1364/OE.27.036329
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The three-dimensional volumetric imaging capability of optical coherence tomography (OCT) leads to the generation of large amounts of data, which necessitates high speed acquisition followed by high dimensional image processing and visualization. This signal acquisition and processing pipeline demands high A-scan rates on the front end, which has driven researchers to push A-scan acquisition rates into the MHz regime. To this end, the optical time-stretch approach uses a mode locked laser (MLL) source, dispersion in optical fiber, and a single analog-to-digital converter (ADC) to achieve multi-MHz A-scan rates. While enabling impressive performance this Nyquist sampling approach is ultimately constrained by the sampling rate and bandwidth of the ADC. Additionally such an approach generates massive amounts of data. Here we present a compressed sensing (CS) OCT system that uses a MLL, electro-optic modulation, and optical dispersion to implement data compression in the physical domain and rapidly acquire real-time compressed measurements of the OCT signals. Compression in the analog domain prior to digitization allows for the use of lower bandwidth ADCs, which reduces cost and decreases the required data capacity of the sampling interface. By leveraging a compressive A-scan optical sampling approach and the joint sparsity of C-scan data we demonstrate 14.4-MHz to 144-MHz A-scan acquisition speeds using a sub-Nyquist 1.44 Gsample/sec ADC sampling rate. Furthermore we evaluate the impact of data compression and resulting imaging speed on image quality. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:36329 / 36339
页数:11
相关论文
共 50 条
  • [1] Towards combined optical coherence tomography and multi-spectral imaging with MHz a-scan rates for endoscopy
    Goeb, Madita
    Pfeiffer, Tom
    Huber, Robert
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA III, 2019, 11078
  • [2] A normative database of A-scan data using the Heidelberg Spectralis Spectral Domain Optical Coherence Tomography machine
    Meyer, Joos
    Karri, Roshan
    Danesh-Meyer, Helen
    Drummond, Kate
    Symons, Andrew
    PLOS ONE, 2021, 16 (07):
  • [3] Statistics of A-scan photocurrent in time-domain optical coherence tomography
    Sherif, Sherif S.
    Chang, Shoude
    Flueraru, Tostel
    PHOTONICS NORTH 2006, PTS 1 AND 2, 2006, 6343
  • [4] Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices
    Chen, Chieh-Li
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Ling, Yun
    Bilonick, Richard A.
    Kagemann, Larry
    Sigal, Ian A.
    Schuman, Joel S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3463 - 3471
  • [5] Imaging of human finger nail-fold with MHz A-scan rate swept source optical coherence tomography
    Poddar, Raju
    Mondal, Indranil
    LASER PHYSICS, 2018, 28 (07)
  • [6] High-resolution retinal swept source optical coherence tomography with an ultra-wideband Fourier-domain mode-locked laser at MHz A-scan rates
    Kolb, Jan Philip
    Pfeiffer, Tom
    Eibl, Matthias
    Hakert, Hubertus
    Huber, Robert
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (01): : 120 - 130
  • [7] Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns
    Kraus, Martin F.
    Potsaid, Benjamin
    Mayer, Markus A.
    Bock, Ruediger
    Baumann, Bernhard
    Liu, Jonathan J.
    Hornegger, Joachim
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1182 - 1199
  • [8] An open access normative database and smart phone application of A-scan data using the Heidelberg Spectralis spectral domain optical coherence tomography machine
    Meyer, Joos
    Karri, Roshan
    Danesh-Meyer, Helen V.
    Drummond, Kate
    Symons, Andrew
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 855 - 856
  • [9] Optical amplification of the signal and sensitivity of the ultrafast spectral domain optical coherence tomography at an A-scan rate of 10MHz in a wavelength region of 1300nm
    Choi, D.
    Hiro-oka, H.
    Shimizu, K.
    Ohbayashi, K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [10] Ultrahigh-Speed Spectral-Domain Optical Coherence Tomography up to 1-MHz A-Scan Rate Using Space-Time-Division Multiplexing
    Seong, Daewoon
    Jeon, Deokmin
    Wijesinghe, Ruchire Eranga
    Park, Kibeom
    Kim, Hyeree
    Lee, Euimin
    Jeon, Mansik
    Kim, Jeehyun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70