Intracorneal ring segment depth in keratoconus patients: a long-term follow-up study

被引:5
|
作者
Shahhoseini, Saied [1 ]
Hashemi, Hassan [2 ]
Asgari, Soheila [3 ]
机构
[1] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[2] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Intracorneal ring segment; Femtosecond laser; Anterior OCT; Actual depth; FEMTOSECOND LASER; IMPLANTATION; INTACS; MANAGEMENT; MODERATE; EFFICACY; CREATION; EYES;
D O I
10.1007/s10792-017-0595-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the actual depth of the tunnel created with femtosecond laser for intracorneal ring segment (ICRS) implantation with the target depth in keratoconus patients. In this mix design study, eligible keratoconus patients were identified through chart review. The inclusion criterion was a history of ICRS implantation with femtosecond laser more than 6 months prior to enrollment. Participants underwent anterior segment optical coherence tomography using Spectralis (Heidelberg Engineering GmbH, Heidelberg, Germany) for depth measurement defined as the distance from the anterior corneal surface to anterior rim of the ring. The mean age of the 30 participants was 31.4 +/- 7.9 years, and 58.6% were male. Mean follow-up time after ring implantation was 25.8 +/- 10.0 (range 7-41) months. Mean actual depth was 59.9% (42.4-86.8%), and the target depth was 85.0% (74.8-90.0%) (P < 0.001). The ring was at a depth of less than 70% in 25 eyes of the 30 (83.3%) studied eyes. The mean 26 months after implantation, ring segments are placed at a shallower depth than originally intended. Therefore, although femtosecond laser technology is an acceptable method for the surgeon, it is necessary to revisit the depth calculator of the device.
引用
收藏
页码:1379 / 1383
页数:5
相关论文
共 50 条
  • [1] Intracorneal ring segment depth in keratoconus patients: a long-term follow-up study
    Saied Shahhoseini
    Hassan Hashemi
    Soheila Asgari
    International Ophthalmology, 2018, 38 : 1379 - 1383
  • [2] Intracorneal ring segments for keratoconus correction:: Long-term follow-up
    Alio, Jorge L.
    Shabayek, Mohamed H.
    Artola, Alberto
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06): : 978 - 985
  • [3] Long-term follow up of intracorneal ring segment implantation in 932 keratoconus eyes
    Warrak, E. L.
    Serhan, H. A.
    Ayash, J. G.
    Wahab, C. H.
    Baban, T. A.
    Daoud, R. C.
    Sammouh, F. K.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2020, 43 (10): : 1020 - 1024
  • [4] Long-term follow-up on intracorneal ring segment inserted for the correction of myopia
    Klug, Sidsel Ehlers
    Hjortdal, Jesper
    Ehlers, Niels
    ACTA OPHTHALMOLOGICA, 2009, 87 (08) : 920 - 921
  • [5] Implantation of intracorneal ring segments in pediatric patients: long-term follow-up
    Abreu, Ana Carolina
    Malheiro, Luisa
    Coelho, Joao
    Neves, Miguel Mesquita
    Gomes, Miguel
    Oliveira, Luis
    Meneres, Pedro
    INTERNATIONAL MEDICAL CASE REPORTS JOURNAL, 2018, 11 : 23 - 27
  • [6] Long-Term Follow-up of Intrastromal Corneal Ring Segment Implantation in Pediatric Keratoconus
    Alfonso, Jose F.
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Monteiro, Tiago
    Madrid-Costa, David
    CORNEA, 2019, 38 (07) : 840 - 846
  • [7] Long-term follow-up of intrastromal corneal ring segments in keratoconus
    Torquetti, Leonardo
    Berbel, Rodrigo Fabri
    Ferrara, Paulo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10): : 1768 - 1773
  • [8] Long-term follow-up of intacs in keratoconus
    Kymionis, George D.
    Siganos, Charalambos S.
    Tsiklis, Nikolaos S.
    Anastasakis, Anastasios
    Yoo, Sonia H.
    Pallikaris, Aristofanis I.
    Astyrakakis, Nikolaos
    Pallikaris, Ioannis G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 236 - 244
  • [9] LONG-TERM FOLLOW-UP OF EPIKERATOPHAKIA FOR KERATOCONUS
    UUSITALO, RJ
    UUSITALO, HM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1476 - 1476
  • [10] Long-term follow-up of penetrating keratoplasty for keratoconus
    Filipec, M
    Letko, E
    ADVANCES IN CORNEAL RESEARCH: SELECTED TRANSACTIONS OF THE WORLD CONGRESS ON THE CORNEA IV, 1997, : 503 - 510