共 50 条
First/Preliminary Experience of Gore Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Fenestrated and Branched Endovascular Aortic Repair
被引:18
|作者:
Gallitto, Enrico
[1
]
Faggioli, Gianluca
[1
]
Pini, Rodolfo
[1
]
Mascoli, Chiara
[1
]
Sonetto, Alessia
[1
]
Abualhin, Mohammad
[1
]
Logiacco, Antonino
[1
]
Ricco, Jean-Baptiste
[2
]
Gargiulo, Mauro
[1
]
机构:
[1] Univ Bologna, Dept Expt Diagnost & Specialty Med, Policlin St Orsola Malpighi, Vasc Surg, Bologna, Italy
[2] Univ Hosp Poitiers, DRCI, Poitiers, France
关键词:
SPINAL-CORD ISCHEMIA;
EDITORS CHOICE;
ANEURYSM REPAIR;
OUTCOMES;
GRAFTS;
IMPACT;
D O I:
10.1016/j.avsg.2019.04.049
中图分类号:
R61 [外科手术学];
学科分类号:
摘要:
Background: The aim of this study is to evaluate the preliminary outcomes of the Gore (R) Viabahn (R) balloon-expandable endoprosthesis (VBX) as bridging stent for fenestrated/branched aortic endograft. Methods: Between April and June 2018, patients undergoing fenestrated and branched-endovascular aortic repair were prospectively collected. Anatomical, procedural, and post-operative data of patients treated with VBX as bridging stents to connect fenestrations/branches to target visceral vessels (TVVs) were analyzed. Technical success and any TVV- related adverse event were assessed before discharge, at 30 days, and after 6 months of follow-up. Results: Fifteen patients undergoing fenestrated and branched-endovascular aortic repair for juxta/pararenal aneurysms (11), proximal type I endoleak after endovascular aortic repair (1), and thoracoabdominal aneurysms (3) were included in the study. Overall, 60 TVVs-celiac trunk (n = 14), superior mesenteric artery (n = 13), renal arteries (n = 30), hypogastric artery (n = 3)-were accommodated by fenestrations (n = 51), branches (n = 7), and scallops (n = 2). The bridging stent graft was a VBX in 40 (67%) TVVs. A renal artery dissection was successfully managed by a self-expandable bare metal stent. Overall, relining of a bridging stent graft was required in 2 TVVs revascularized by fenestrations (superior mesenteric artery: n = 1, renal artery: n = 1). One intraoperative type III endoleak from renal fenestration was detected and successfully sealed by an adjunctive flaring maneuver. Technical success was achieved in all cases. At 5-day, 1 VBX (1/40: 2.5%) lost its sealing in a renal artery revascularized by a branch (type II thoracoabdominal aortic aneurysm) and required reintervention and relining with a self-expandable stent graft. No TVV occlusion or reintervention occurred <30 days or after 6 months of follow-up. Conclusions: According to these preliminary results, the Gore Viabahn VBX balloon-expandable endoprosthesis can be safely used as bridging stent graft for fenestrated or branched endografts. A longer follow-up with a larger case load is necessary in order to validate this preliminary experience.
引用
收藏
页码:299 / 309
页数:11
相关论文