Modeling the detection efficiency of an HP-Ge detector for use in boron neutron capture therapy

被引:7
|
作者
Nakamura, Satoshi [1 ]
Wakita, Akihisa [1 ]
Ito, Masashi [1 ]
Okamoto, Hiroyuki [1 ]
Nishioka, Shie [1 ]
Iijima, Kotaro [1 ]
Kobayashi, Kazuma [1 ]
Nishio, Teiji [2 ]
Igaki, Hiroshi [1 ]
Itami, Jun [1 ]
机构
[1] Natl Canc Ctr, Dept Radiat Oncol, Chuo Ku, 5-1-1 Tsukiji, Tokyo 1040045, Japan
[2] Tokyo Womens Univ, Grad Sch Med, Dept Med Phys, Shinjyuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
关键词
BNCT; HP-Ge detector; Detection efficiency; Modeling procedure; Multi-foil method; IRRADIATION-FACILITY; UNIVERSITY; SPECTRA; SYSTEM; FIELD; BNCT;
D O I
10.1016/j.apradiso.2017.03.027
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The multi-foil method is commonly used to determine upon an energy spectrum of neutrons in boron neutron capture therapy. The method requires to measure the radioactivation of the foils. This study develops a simple modeling procedure of a high-purity Ge detector, which is used to measure the radioactivation, in order to calculate the detection efficiency with GEANT4. By changing four parameters from their manufacturing specifications of the detector, the simulated detection efficiency is able to reproduce the actual detection efficiency.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [1] Thickness-dependent neutron detection efficiency of LiF-Si-based active neutron detector for boron neutron capture therapy
    Takada, Masashi
    Endo, Satoru
    Kajimoto, Tsuyoshi
    Horiguchi, Tetsuo
    Yamanishi, Hirokuni
    Yagi, Natsumi
    Masuda, Akihiko
    Matsumoto, Tetsuro
    Tanaka, Hiroki
    Nunomiya, Tomoya
    Aoyama, Kei
    Narita, Masataka
    Nakamura, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [2] GE PETtrace cyclotron as a neutron source for boron neutron capture therapy
    Bosko, A
    Zhilchenkov, D
    Reece, WD
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1057 - 1062
  • [3] Mechanism of secondary gamma-ray skyshine from intense 14 MeV neutron source facility with Hp-Ge detector
    Murata, I
    Yoshida, S
    Saito, N
    Takahashi, A
    FUSION TECHNOLOGY, 1998, 34 (03): : 997 - 1001
  • [4] Clinical Use of Radiopharmaceuticals in Boron Neutron Capture Therapy
    Lee, Yun-Sang
    Seo, Hyo Jung
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 56 (03) : 111 - 113
  • [5] Clinical Use of Radiopharmaceuticals in Boron Neutron Capture Therapy
    Yun-Sang Lee
    Hyo Jung Seo
    Nuclear Medicine and Molecular Imaging, 2022, 56 : 111 - 113
  • [6] Initial trials of a dose monitoring detector for boron neutron capture therapy
    Bykov, T. A.
    Kasatov, D. A.
    Koshkarev, A. M.
    Makarov, A. N.
    Porosev, V. V.
    Savinov, G. A.
    Shchudlo, I. M.
    Taskaev, S. Yu
    Verkhovod, G. D.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (01)
  • [7] Microstructure Boron Detector for High Efficiency Thermal Neutron Detection
    Fujiwara, T.
    Takahashi, H.
    Yamada, N. L.
    Uesaka, M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Measurement of secondary gamma-ray skyshine from intense 14 MeV neutron source facility with Hp-Ge detector
    Yoshida, S
    Saito, N
    Murata, I
    Takahashi, A
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 1392 - 1394
  • [9] BeNEdiCTE (Boron Neutron Capture): A Versatile Gamma-Ray Detection Module for Boron Neutron Capture Therapy
    Caracciolo, Anita
    Buonanno, Luca
    Di Vita, Davide
    D'Adda, Ilenia
    Chacon, Andrew
    Kielly, Marissa
    Carminati, Marco
    Safavi-Naeini, Mitra
    Fiorini, Carlo
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (08) : 886 - 892
  • [10] AN EQUIVALENT THERMAL-NEUTRON FLUENCE DETECTOR FOR BORON NEUTRON-CAPTURE THERAPY
    BLUE, TE
    WANG, CKC
    BLUE, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (09): : 1301 - 1307