Surface composition analysis of failed cementless CoCr- and Ti-base-alloy total hip implants

被引:10
|
作者
Decking, R
Reuter, P
Hüttner, M
Puhl, W
Claes, LE
Scharf, HP
机构
[1] Univ Ulm, Dept Orthoped Surg, RKU, D-89081 Ulm, Germany
[2] Univ Ulm, Dept Biomat, D-89069 Ulm, Germany
[3] Univ Ulm, Dept Surface Chem & Catalysis, D-89069 Ulm, Germany
[4] Univ Ulm, Inst Orthoped Res & Biomech, D-89069 Ulm, Germany
关键词
arthroplasty; hip; SEM; EDX; XPS;
D O I
10.1002/jbm.b.10555
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The surfaces of retrieved failed cementless total hip implants made of cobalt-chromium-molybdenum casting alloy and of wrought titanium 6-aluminum 4-vanadium alloy were studied with the use of scanning-electron microscopy (SEM), energy-dispersive X-ray analysis (EDX) and X-ray photoelectron spectroscopy (XPS). New implants of the same make served as controls. The XPS scans revealed a dense carbon layer on the entire analyzed specimen. The relative composition of the titanium alloy implants showed an overall agreement with the international standards for implants for surgery, and the overall surface composition did not change over the period of the implantation. However, an inhomogeneous distribution of the constituents could be demonstrated in the retrieved as well as in the new MEC-screw rings made of TiAl6V4 alloy, an implant that has been linked to a high early failure rate. In the CoCr-alloy components (Lord-screw rings) a high percentage of aluminum, mainly organized in aluminum inclusions, was found in the retrieved as well as in the new implants. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 21 条
  • [1] Surface analysis of a femoral stem after failed total hip replacement
    G. Maccauro
    C. Piconi
    L. Pilloni
    L. Proietti
    V. De Santis
    E. De Santis
    International Orthopaedics, 2000, 24 : 231 - 233
  • [2] Surface analysis of a femoral stem after failed total hip replacement
    Maccauro, G
    Piconi, C
    Pilloni, L
    Proietti, L
    De Santis, V
    De Santis, E
    INTERNATIONAL ORTHOPAEDICS, 2000, 24 (04) : 231 - 233
  • [3] Contamination of surfaces for osseointegration of cementless total hip implants by small aluminium oxide particles: analysis of established implants by use of a new technique
    Kolb, Alexander
    Reinisch, Georg
    Sabeti-Aschraf, Manuel
    Gruebl, Alexander
    Windhager, Reinhard
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (02) : 245 - 249
  • [4] Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty
    Leuridan, Steven
    Goossens, Quentin
    Pastrav, Leonard Cezar
    Mulier, Michiel
    Desmet, Wim
    Vander Sloten, Jos
    Denis, Kathleen
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2021, 9
  • [5] Microscopic analysis of characteristic surface features of a set of retrieved total hip implants
    Burbano, Maria
    Roy, Diana
    Russell, Robert
    Huo, Michael
    Rodrigues, Danieli
    FASEB JOURNAL, 2014, 28 (01):
  • [6] Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty
    Chang, PB
    Robie, BH
    Bartel, DL
    JOURNAL OF BIOMECHANICS, 1999, 32 (12) : 1309 - 1318
  • [7] Surface Properties of Retrieved Cementless Femoral Hip Endoprostheses Produced from a Ti6Al7Nb Alloy
    Avsec, Klemen
    Jenko, Monika
    Conradi, Marjetka
    Kocijan, Aleksandra
    Vesel, Alenka
    Kovac, Janez
    Godec, Matjaz
    Belic, Igor
    Batic, Barbara Setina
    Donik, Crtomir
    Gorensek, Matevz
    Kocjancic, Bostjan
    Dolinar, Drago
    COATINGS, 2019, 9 (12)
  • [8] METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS
    AGINS, HJ
    ALCOCK, NW
    BANSAL, M
    SALVATI, EA
    WILSON, PD
    PELLICCI, PM
    BULLOUGH, PG
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03): : 347 - 356
  • [9] High Revision Rates of a Cementless Beta-Titanium Alloy Stem with Contamination-Free Roughened Surface in Primary Total Hip Arthroplasty
    Stenicka, Sandra
    Hanreich, Carola
    Babeluk, Rita
    Kubista, Bernd
    Giurea, Alexander
    Sigmund, Irene Katharina
    Windhager, Reinhard
    Kotz, Rainer
    Lass, Richard
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 12
  • [10] Failure analysis of two Ti-alloy total hip arthroplasty femoral stems fractured in vivo
    Magnissalis, EA
    Zinelis, S
    Karachalios, T
    Hartofilakidis, G
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 66B (01) : 299 - 305