Development of a method for reliable power input measurements in conventional and single-use stirred bioreactors at laboratory scale

被引:15
|
作者
Kaiser, Stephan C. [1 ]
Werner, Soren [2 ]
Jossen, Valentin [2 ]
Kraume, Matthias [3 ]
Eibl, Dieter [2 ]
机构
[1] Finesse Solut Inc, 3501 Leonard Court, Santa Clara, CA 95054 USA
[2] Zurich Univ Appl Sci, Inst Chem & Biotechnol, Wadenswil, Switzerland
[3] Tech Univ Berlin, Fachgebiet Verfahrenstech, Berlin, Germany
来源
ENGINEERING IN LIFE SCIENCES | 2017年 / 17卷 / 05期
关键词
Measurement; Power input; Single-use bioreactors; Stirrers Torque; IMPELLER TYPE; CONSUMPTION; GEOMETRY; VESSELS; NUMBERS; DESIGN; CELLS; TANKS; MODEL;
D O I
10.1002/elsc.201600096
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Power input is an important engineering and scale-up/down criterion in stirred bioreactors. However, reliably measuring power input in laboratory-scale systems is still challenging. Even though torque measurements have proven to be suitable in pilot scale systems, sensor accuracy, resolution, and errors from relatively high levels of friction inside bearings can become limiting factors at smaller scales. An experimental setup for power input measurements was developed in this study by focusing on stainless steel and single-use bioreactors in the single-digit volume range. The friction losses inside the air bearings were effectively reduced to less than 0.5% of themeasurement range of the torque meter. A comparison of dimensionless power numbers determined for a reference Rushton turbine stirrer (N-P = 4.17 +/- 0.14 for fully turbulent conditions) revealed good agreement with literature data. Hence, the power numbers of several reusable and single-use bioreactors could be determined over a wide range of Reynolds numbers between 100 and > 10(4). Power numbers of between 0.3 and 4.5 (for Re = 10(4)) were determined for the different systems. The rigid plastic vessels showed similar power characteristics to their reusable counterparts. Thus, it was demonstrated that the torque-based technique can be used to reliably measure power input in stirred reusable and single-use bioreactors at the laboratory scale.
引用
收藏
页码:500 / 511
页数:12
相关论文
共 50 条
  • [1] Power Input Measurements in Stirred Bioreactors at Laboratory Scale
    Kaiser, Stephan C.
    Werner, Soeren
    Jossen, Valentin
    Blaschczok, Katharina
    Eibl, Dieter
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (135):
  • [2] On the fluid dynamics of a laboratory scale single-use stirred bioreactor
    Odeleye, A. O. O.
    Marsh, D. T. J.
    Osborne, M. D.
    Lye, G. J.
    Micheletti, M.
    CHEMICAL ENGINEERING SCIENCE, 2014, 111 : 299 - 312
  • [3] Single-Use Bioreactors: To Scale Up or Scale Out?
    Mirasol, Feliza
    BIOPHARM INTERNATIONAL, 2020, 33 (01) : 19 - 21
  • [4] CFD SIMULATION OF SMALL-SCALE SINGLE-USE STIRRED TANK BIOREACTORS; COMPARISONS AND PERSPECTIVES
    Gaddum, N.
    Baptista, R. P.
    Delahaye, M.
    Fraser, H.
    Partington, L.
    Popova, D.
    Mirmalek-Sani, H.
    Ward, S.
    CYTOTHERAPY, 2017, 19 (05) : S74 - S74
  • [5] Measurement of heat transfer coefficients in stirred single-use bioreactors by the decay of hydrogen peroxide
    Mueller, Matthias
    Meusel, Wolfram
    Husemann, Ute
    Greller, Gerhard
    Kraume, Matthias
    ENGINEERING IN LIFE SCIENCES, 2017, 17 (12): : 1234 - 1243
  • [6] Fully automated single-use stirred-tank bioreactors for parallel microbial cultivations
    Andreas Kusterer
    Christian Krause
    Klaus Kaufmann
    Matthias Arnold
    Dirk Weuster-Botz
    Bioprocess and Biosystems Engineering, 2008, 31 : 207 - 215
  • [7] Fully automated single-use stirred-tank bioreactors for parallel microbial cultivations
    Kusterer, Andreas
    Krause, Christian
    Kaufmann, Klaus
    Arnold, Matthias
    Weuster-Botz, Dirk
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2008, 31 (03) : 207 - 215
  • [8] Scale-up analysis of geometrically dissimilar single-use bioreactors
    Kreitmayer, Diana
    Gopireddy, Srikanth R.
    Aki, Yuichi
    Nonaka, Koichi
    Urbanetz, Nora A.
    Gutheil, Eva
    BIOTECHNOLOGY AND BIOENGINEERING, 2023, 120 (11) : 3381 - 3395
  • [9] High-throughput fermentation process design with single-use stirred-tank bioreactors
    Weuster-Botz, Dirk
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S279 - S280
  • [10] Model Predictive Feeding Rate Control in Conventional and Single-use Lab-scale Bioreactors: A Study on Practical Application
    Grigs, O.
    Galvanauskas, V.
    Dubencovs, K.
    Vanags, J.
    Suleiko, A.
    Berzins, T.
    Kunga, L.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2016, 30 (01) : 47 - 60