Push-out bond strength of CAD/CAM-ceramic luted to dentin with self-adhesive resin cements

被引:22
|
作者
Flury, Simon [1 ]
Lussi, Adrian [1 ]
Peutzfeldt, Anne [1 ]
Zimmerli, Brigitte [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prevent Restorat & Pediat Dent, CH-3010 Bern, Switzerland
关键词
Luting agents; Thermocycling; Storage; Ceramic restoration; Computer-aided; design/manufacturing; 5-YEAR CLINICAL-EVALUATION; IN-VITRO; LUTING CEMENTS; INLAYS; COMPOSITE; RESTORATIONS; SYSTEMS; ENAMEL; AGENTS; PERFORMANCE;
D O I
10.1016/j.dental.2010.05.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study evaluated the initial and the artificially aged push-out bond strength between ceramic and dentin produced by one of five resin cements. Methods. Two-hundred direct ceramic restorations (IPS Empress CAD) were luted to standardized Class I cavities in extracted human molars using one of four self-adhesive cements (SpeedCEM, RelyX Unicem Aplicap, SmartCem2 and iCEM) or a reference etch-and-rinse resin cement (Syntac/Variolink II) (n = 40/cement). Push-out bond strength (PBS) was measured (1) after 24h water storage (non-aged group; n = 20/cement) or (2) after artificial ageing with 5000 thermal cycles followed by 6 months humid storage (aged group; n = 20/cement). Nonparametrical ANOVA and pairwise Wilcoxon rank-sum tests with Bonferroni-Holm adjustment were applied for statistical analysis. The significance level was set at alpha= 0.05. In addition, failure mode and fracture pattern were analyzed by stereomicroscope and scanning electron microscopy. Results. Whereas no statistically significant effect of storage condition was found (p = 0.441), there was a significant effect of resin cement (p < 0.0001): RelyX Unicem showed significantly higher PBS than the other cements. Syntac/Variolink II showed significantly higher PBS than SmartCEM2 (p < 0.001). No significant differences were found between SpeedCEM, SmartCem2, and iCEM. The predominant failure mode was adhesive failure of cements at the dentin interface except for RelyX Unicem which in most cases showed cohesive failure in ceramic. Significance. The resin cements showed marked differences in push-out bond strength when used for luting ceramic restorations to dentin. Variolink II with the etch-and-rinse adhesive Syntac did not perform better than three of the four self-adhesive resin cements tested. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:855 / 863
页数:9
相关论文
共 50 条
  • [1] Push-Out Bond Strength of Quartz Fiber Posts Luted with Self-Adhesive and Conventional Resin Cements
    Cardoso Vieira, Luiz Clovis
    Araujo, Elito
    Ramirez Barrantes, Juan Carlos
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2016, 18 (02) : 73 - 90
  • [2] Push-out bond strength of an experimental self-adhesive resin cement
    Juloski, Jelena
    Fadda, Giovanni M.
    Radovic, Ivana
    Chieffi, Nicoletta
    Vulicevic, Zoran R.
    Aragoneses, Juan M.
    Ferrari, Marco
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2013, 121 (01) : 50 - 56
  • [3] Effect of Sonic Application of Self-Adhesive Resin Cements on Push-Out Bond Strength of Glass Fiber Posts to Root Dentin
    Lima, Darlon Martins
    Linhares, Thatyla Silva
    Linares Lima, Suellen Nogueira
    Carvalho, Edilausson Moreno
    Loguercio, Alessandro Dourado
    Bauer, Jose
    Carvalho, Ceci Nunes
    MATERIALS, 2019, 12 (12):
  • [4] Bond strength of modern self-adhesive resin cements to human dentin and different CAD/CAM ceramics
    Malysa, Andrzej
    Wezgowiec, Joanna
    Danel, Dariusz
    Boening, Klaus
    Walczak, Katarzyna
    Wieckiewicz, Mieszko
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2020, 22 (02) : 25 - 34
  • [5] Push-out bond strength and SEM analysis of two self-adhesive resin cements: An in vitro study
    Baldea, Bogdan
    Furtos, Gabriel
    Antal, Mark
    Nagy, Katalin
    Popescu, Dragos
    Nica, Luminita
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (03) : 296 - 305
  • [6] Push-out Bond Strength of Self-adhesive Methacrylate Resin-based Sealers to Root Dentin
    孙燕
    李宇红
    樊明文
    Current Medical Science, 2014, (01) : 108 - 113
  • [7] Push-out bond strength of self-adhesive methacrylate resin-based sealers to root dentin
    Sun, Yan
    Li, Yu-hong
    Fan, Ming-wen
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (01) : 108 - 113
  • [8] Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block
    Berkman, Meric
    Tuncer, Safa
    Tekce, Neslihan
    Karabay, Ferda
    Demirci, Mustafa
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (01) : 116 - 125
  • [9] Push-out bond strength of self-adhesive methacrylate resin-based sealers to root dentin
    Yan Sun
    Yu-hong Li
    Ming-wen Fan
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 108 - 113
  • [10] Tensile bond strength of indirect composites luted with three new self-adhesive resin cements to dentin
    Turkmen, Cafer
    Durkan, Meral
    Cimilli, Hale
    Oksuz, Mustafa
    JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (04) : 363 - 369