A novel method for the activity measurement of large-area beta reference sources

被引:0
|
作者
Stanga, D. [1 ]
De Felice, P. [2 ]
Keightley, J. [3 ]
Capogni, M. [2 ]
Ioan, M. R. [1 ]
机构
[1] Natl Inst R&D Phys & Nucl Engn Horia Hulubei, IFIN HH, POB MG 6, R-077125 Bucharest, Romania
[2] Inst Nazl Metrol Radiaz Ionizzante, ENEA, CR Casaccia, POB 2400, I-00100 Rome, Italy
[3] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
关键词
Method of measurement; Large area reference sources; Numerical model; CALIBRATION; EFFICIENCY;
D O I
10.1016/j.apradiso.2015.12.030
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A novel method has been developed for the activity measurement of large-area beta reference sources. It makes use of two emission rate measurements and is based on the weak dependence between the source activity and the activity distribution for a given value of transmission coefficient. The method was checked experimentally by measuring the activity of two (Co-60 and Cs-137) large-area reference sources constructed from anodized aluminum foils. Measurement results were compared with the activity values measured by gamma spectrometry. For each source, they agree within one standard uncertainty and also agree within the same limits with the certified values of the source activity. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:358 / 362
页数:5
相关论文
共 50 条
  • [1] On the determination of activity profiles in large-area reference sources
    Janssen, H
    Thieme, K
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 677 - 682
  • [2] Characterization of large-area reference sources for the calibration of beta-contamination monitors
    Janssen, H
    Klein, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 552 - 556
  • [3] Improvements in the absolute standardization of large-area reference sources
    Stanga, D.
    De Felice, P.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (09) : 1716 - 1720
  • [4] A simple method for determining the activity of large-area beta sources constructed from anodized aluminum foils
    Stanga, D.
    APPLIED RADIATION AND ISOTOPES, 2014, 87 : 211 - 215
  • [5] A novel method for large-area sources preparation for the calibration of β- and α-contamination monitors
    Tsoupko-Sitnikov, V
    Picolo, JL
    Carrier, M
    Peulon, S
    Moutard, G
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 21 - 29
  • [6] Variability - Surface intensity distribution of large-area reference sources
    da Silva Jr, Iremar Alves
    Siqueira, Paulo de T. D.
    do Nascimento, Eduardo
    Yoriyaz, Helio
    Sordi, Gian-Maria A. A.
    Potiens, Maria de Penha A.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [7] An advanced method of activity determination of large area beta emitting sources
    Javornik, Andrej
    Svec, Anton
    APPLIED RADIATION AND ISOTOPES, 2014, 87 : 216 - 219
  • [8] LARGE-AREA PLASMA SOURCES
    EHLERS, KW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (10): : 1296 - 1296
  • [9] Correction factors for non-uniform large-area reference sources
    Silva Jr, Iremar Alves
    Siqueira, Paulo de T. D.
    do Nascimento, Eduardo
    Yoriyaz, Helio
    Sordi, Gian-Maria A. A.
    Vivolo, Vitor
    Potiens, Maria Penha A.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [10] Uniformity measurement of wide area reference sources for beta emitters
    Ohshiro, Masahiro
    Shiina, Takuya
    Yamada, Takahiro
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 397 - 401