Adaptation and validation of an Arabic version of a 10-item patient-reported outcome measure of physical function in rheumatoid arthritis

被引:1
|
作者
Farrag, Shaza Mohamed [1 ]
Abdelnaby, Mai Mohamed [2 ]
Mohamed, Aly Elsayed [2 ]
机构
[1] Damietta Specialized Hosp, Dept Phys Med Rheumatol & Rehabil, Dumyat, Egypt
[2] Suez Canal Univ, Fac Med, Dept Phys Med Rheumatol & Rehabil, Ring Rd,K4-5,PO 41522, Ismailia, Egypt
关键词
Arabic PF-10a; patient-reported outcomes measures; physical function; rheumatoid arthritis; validation; QUALITY-OF-LIFE; AMERICAN-COLLEGE; SCALES;
D O I
10.1111/1756-185X.13763
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To adapt and validate an Arabic version of the short form of physical function measure (PF-10a), a generic questionnaire for physical function, in Egyptian patients with rheumatoid arthritis (RA). Methods After standardized linguistic validation of the Arabic version of PF-10a, with forward and backward translation, the questionnaire was completed by 70 Egyptian RA patients who were diagnosed according to American College of Rheumatology/European League Against Rheumatism 2010 classification criteria, on two occasions 3-5 days apart. The internal consistency and test-retest reliability were evaluated using Cronbach's alpha and intra-class correlation. The content validity of the Arabic PF-10a was tested against Health Assessment Questionnaire Disability Index (HAQ-DI), Clinical Disease Activity Index (CDAI) and Disease Activity Score in 28 joints using erythrocyte sedimentation rate (DAS28-ESR). In addition, serology results, hand radiographs, and treatments received were all recorded. Results Most of our patients were female (88.6%) with a mean age of 49.2 +/- 10.5 years. They had a mean disease duration of 7.3 +/- 7 years and an active disease with a mean CDAI of 33.1 +/- 12.6. The mean value of PF-10a was 34.6 +/- 6.2. The Cronbach's alpha for Arabic PF-10a was 0.904. Intra-CLASS CORRELATION was 0.897. Arabic PF-10a correlated strongly with HAQ-DI (-0.746), moderately with CDAI, patient global assessment, and pain (-0.457, -0.417, and -0.371 respectively). Conclusion The validation study showed that the Arabic PF-10a had acceptable psychometric characteristics, in terms of internal consistency and construct validity. The Arabic PF-10a is a reliable and valid instrument to be used by Arabic RA patients.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 50 条
  • [1] Validity and Responsiveness of a 10-Item Patient-Reported Measure of Physical Function in a Rheumatoid Arthritis Clinic Population
    Wahl, Elizabeth
    Gross, Andrew
    Chernitskiy, Vladimir
    Trupin, Laura
    Gensler, Lianne
    Chaganti, Krishna
    Michaud, Kaleb
    Katz, Patricia
    Yazdany, Jinoos
    ARTHRITIS CARE & RESEARCH, 2017, 69 (03) : 338 - 346
  • [2] Development of a patient-reported outcome measure for the foot affected by rheumatoid arthritis
    Walmsley, Steven
    Ravey, Mike
    Graham, Andrea
    Teh, Lee S.
    Williams, Anita E.
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2012, 65 (04) : 413 - 422
  • [3] Cross-cultural adaptation of an Arabic version of the 10-item hearing handicap inventory
    Weinstein, Barbara E.
    Rasheedy, Doha
    Taha, Hend M.
    Fatouh, Fathy N.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (05) : 341 - 346
  • [4] Validation of the Italian version of a patient-reported outcome measure for Hereditary Spastic Paraplegia
    Diella, Eleonora
    D'Angelo, Maria Grazia
    Stefan, Cristina
    Girardi, Giulia
    Morganti, Roberta
    Martinuzzi, Andrea
    Biffi, Emilia
    PLOS ONE, 2024, 19 (04):
  • [5] Validation of a Swedish version of a short patient-reported outcome measure for superficial venous insufficiency
    Hultman, Karolina Helczynska
    Sinabulya, Helen
    Blomgren, Lena
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (02) : 416 - +
  • [6] Translation, cultural adaptation and validation of the Danish version of the haematological malignancy patient-reported outcome measure (HM-PRO)
    Sam Salek
    Sören Möller
    Niels Abildgaard
    Tine Rosenberg
    Maria Torp Larsen
    Peter Asdahl
    Kasper Kofod Pedersen
    Marie Therese Lassen
    Christen Lykkegaard Andersen
    Lene Kongsgaard Nielsen
    Journal of Patient-Reported Outcomes, 9 (1)
  • [7] Validation and implementation of a patient-reported experience measure for patients with rheumatoid arthritis and spondyloarthritis in the Netherlands
    Esther Beckers
    Casper Webers
    Annelies Boonen
    Peter M. ten Klooster
    Harald E. Vonkeman
    Astrid van Tubergen
    Clinical Rheumatology, 2020, 39 : 2889 - 2897
  • [8] Validation and implementation of a patient-reported experience measure for patients with rheumatoid arthritis and spondyloarthritis in the Netherlands
    Beckers, Esther
    Webers, Casper
    Boonen, Annelies
    ten Klooster, Peter M.
    Vonkeman, Harald E.
    van Tubergen, Astrid
    CLINICAL RHEUMATOLOGY, 2020, 39 (10) : 2889 - 2897
  • [9] Adaptation and Validation of the Polish Version of the 10-Item Mobile Phone Problematic Use Scale
    Mach, Anna
    Demkow-Jania, Marta
    Klimkiewicz, Anna
    Jakubczyk, Andrzej
    Abramowska, Malgorzata
    Kuciak, Anna
    Serafin, Piotr
    Szczypinski, Jan
    Wojnar, Marcin
    FRONTIERS IN PSYCHIATRY, 2020, 11
  • [10] Translation and Cultural Adaptation into Arabic of Patient-Reported Outcome Measurement Information System® Item Banks: Cognitive Function Abilities and Physical Function for Samples with Mobility Aid Users
    Almohaya, Hadeil S.
    Bakhsh, Hadeel R.
    Bin Sheeha, Bodor
    Aldhahi, Monira I.
    Alhasani, Rehab
    HEALTHCARE, 2024, 12 (02)