The use of liquid chromatography/mass spectrometry for quantitative analysis of oxycodone, oxymorphone and noroxycodone in Ringer solution, rat plasma and rat brain tissue

被引:21
|
作者
Boström, E [1 ]
Jansson, B [1 ]
Hammarlund-Udenaes, M [1 ]
Simonsson, USH [1 ]
机构
[1] Dept Biopharmaceut Sci, Div Pharmacokinet & Drug Therapy, SE-75124 Uppsala, Sweden
关键词
D O I
10.1002/rcm.1658
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sensitive and reproducible methods for the determination of oxycodone, oxymorphone and noroxycodone in Ringer solution, rat plasma and rat brain tissue by liquid chromatography/mass spectrometry are described. Deuterated analogs of the substances were used as internal standards. Samples in Ringer solution were analyzed by direct injection of 10 muL Ringer solution diluted by an equal volume of water. The limit of quantification was 0.5 ng/mL and the method was linear in the range of 0.5-150 ng/mL for all substances. To analyze oxycodone and oxymorphone in rat plasma, 50 muL, of plasma were precipitated with acetonitrile, and the supernatant was directly injected onto the column. To analyze oxycodone, oxymorphone and noroxycodone in rat plasma, 100 muL of rat plasma were subjected to a C18 solid-phase extraction (SPE) procedure, before reconstituting in mobile phase and injection onto the column. For both methods the limit of quantification in rat plasma was 0.5 ng/mL and the methods were linear in the range of 0.5-250 ng/mL for all substances. To analyze the content of oxycodone, oxymorphone and noroxycodone in rat brain tissue, 100 muL of the brain homogenate supernatant were subjected to a C18 SPE procedure. The limit of quantification of oxycodone was 20 ng/g brain, and for oxymorphone and noroxycodone 4 ng/g brain, and the method was linear in the range of 20-1000 ng/g brain for oxycodone and 4-1000 ng/g brain for oxymorphone and noroxycodone. All methods utilized a mobile phase of 5 mM ammonium acetate in 45% acetonitrile, and a SB-CN column was used for separation. The total run time of all methods was 9 min. The intra-day precision and accuracy were <11.3% and <+/-14.9%, respectively, and the inter-day precision and accuracy were <14.9% and <+/-6.5%, respectively, for all the concentrations and matrices described. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:2565 / 2576
页数:12
相关论文
共 50 条
  • [1] Determination of oxycodone, noroxycodone, oxymorphone, and noroxymorphone in human plasma by liquid chromatography-electrospray-tandem mass Spectrometry
    Neuvonen, Mikko
    Neuvonen, Pertti J.
    THERAPEUTIC DRUG MONITORING, 2008, 30 (03) : 333 - 340
  • [2] Development of a sensitive method for the determination of oxycodone and its major metabolites noroxycodone and oxymorphone in human plasma by liquid chromatography-tandem mass spectrometry
    Gaudette, Fleur
    Sirhan-Daneau, Andrea
    St-Onge, Maude
    Turgeon, Jacques
    Michaud, Veronique
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 174 - 180
  • [3] Quantitative Analysis of Neurochemical Panel in Rat Brain and Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Zheng, Xiao
    Kang, An
    Dai, Chen
    Liang, Yan
    Xie, Tong
    Xie, Lin
    Peng, Yin
    Wang, Guangji
    Hao, Haiping
    ANALYTICAL CHEMISTRY, 2012, 84 (22) : 10044 - 10051
  • [4] Quantitative determination of dihydroetorphine in rat plasma and brain by liquid chromatography-tandem mass spectrometry
    Ohmori, S
    Hayashi, T
    Kawase, M
    Saito, S
    Morimoto, Y
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 253 - 263
  • [5] Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases
    Pantano, Flaminia
    Brauneis, Stefano
    Forneris, Alexandre
    Pacifici, Roberta
    Marinelli, Enrico
    Kyriakou, Chrystalla
    Pichini, Simona
    Busardo, Francesco Paolo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (09) : 1324 - 1331
  • [6] Quantitative analysis of phosphatidyllcholline in rat liver tissue by nanoflow liquid chromatography/tandem mass spectrometry
    Ahn, Eun Jeong
    Kim, Hanna
    Chung, Bong Chul
    Moon, Myeong Hee
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (16) : 2598 - 2604
  • [7] Quantitative analyses of phenibut in rat brain tissue extracts by liquid chromatography-tandem mass spectrometry
    Grinberga, Solveiga
    Zvejniece, Liga
    Liepinsh, Edgars
    Dambrova, Maija
    Pugovics, Osvalds
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (12) : 1321 - 1324
  • [8] Quantitative determination of sauchinone in rat plasma by liquid chromatography-mass spectrometry
    Xu, Chun-lei
    Chen, Jian-wei
    Ju, Wen-zheng
    Liu, Shi-jia
    Chen, Yong
    Chen, Zhi-peng
    Xue, Ping
    Chen, Hong-jiang
    Li, Xiang
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (10) : 1210 - 1214
  • [9] Quantitative determination of sparfloxacin in rat plasma by liquid chromatography/tandem mass spectrometry
    Noh, Keumhan
    Kwon, Kwang-il
    Jeong, Tae Cheon
    Kang, Wonku
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) : 1199 - 1202
  • [10] Quantitative determination of daumone in rat plasma by liquid chromatography-mass spectrometry
    Noh, Keumhan
    Park, Jung Hyun
    Park, Jong Hee
    Kim, Minkyu
    Jung, Mankil
    Ha, Hunjoo
    Kwon, Kwang-il
    Lee, Hwa Jeong
    Kang, Wonku
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 114 - 117