Megavoltage cone-beam computed tomography using a high-efficiency image receptor

被引:96
|
作者
Seppi, EJ [1 ]
Munro, P [1 ]
Johnsen, SW [1 ]
Shapiro, EG [1 ]
Tognina, C [1 ]
Jones, D [1 ]
Pavkovich, JM [1 ]
Webb, C [1 ]
Mollov, I [1 ]
Partain, LD [1 ]
Colbeth, RE [1 ]
机构
[1] Varian Med Syst, Ginzton Technol Ctr, Mountain View, CA 94043 USA
关键词
dynamic targeting; megavoltage cone-beam CT; electronic portal imaging device;
D O I
10.1016/S0360-3016(02)04155-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop an image receptor capable of forming high-quality megavoltage CT images using modest radiation doses. Methods and Materials: A flat-panel imaging system consisting of a conventional flat-panel sensor attached to a thick CsI scintillator has been fabricated. The scintillator consists of individual CsI crystals 8 mm thick by 0.38 rum x 0.38-mm pitch. Five sides of each crystal are coated with a reflecting powder/epoxy mixture, and the sixth side is in contact with the flat-panel sensor. A timing interface coordinates acquisition by the imaging system and pulsing of the linear accelerator. With this interface, as little as one accelerator pulse (0.023 cGy at the isocenter) can be used to form projection images. Different CT phantoms irradiated by a 6-MV X-ray beam have been imaged to evaluate the performance of the imaging system. The phantoms have been mounted on a rotating stage and rotated while 360 projection images are acquired in 48 s. These projections have been reconstructed using the Feldkamp cone-beam CT reconstruction algorithm. Results and Discussion: Using an irradiation of 16 cGy (360 projections x 0.046 cGy/projection), the contrast resolution is similar to1% for large objects. High-contrast structures as small as 1.2 rum are clearly visible. The reconstructed CT values are linear (R-2 = 0.98) for electron densities between 0.001 and 2.16 g/cm(3), and the reconstruction time for a 512 x 512 x 512 data set is 6 min. Images of an anthropomorphic phantom show that soft-tissue structures such as the heart, lung, kidneys, and liver are visible in the reconstructed images (16 cGy, 5-mm-thick slices). Conclusions: The acquisition of megavoltage CT images with soft-tissue contrast is possible with irradiations as small as 16 cGy. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:793 / 803
页数:11
相关论文
共 50 条
  • [1] Megavoltage cone-beam computed tomography using a high quantum efficiency image receptor
    Munro, P
    Seppi, E
    Johnsen, S
    Shapiro, E
    Tognina, C
    Jones, D
    Pavkovich, J
    Webb, C
    Mollov, I
    Partain, L
    Colbeth, RE
    MEDICAL PHYSICS, 2002, 29 (06) : 1340 - 1340
  • [2] Low-dose megavoltage cone-beam computed tomography for lung tumors using a high-efficiency image receptor
    Sillanpaa, Jussi
    Chang, Jenghwa
    Mageras, Gikas
    Yorke, Ellen
    De Arruda, Fernando
    Rosenzweig, Kenneth E.
    Munro, Peter
    Seppi, Edward
    Pavkovich, John
    Amols, Howard
    MEDICAL PHYSICS, 2006, 33 (09) : 3489 - 3497
  • [3] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration
    Akino, Yuichi
    Yoshioka, Yasuo
    Fukuda, Shoichi
    Maruoka, Shintaroh
    Takahashi, Yutaka
    Yagi, Masashi
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (03): : 602 - 608
  • [5] Evaluation of male pelvic phantom for megavoltage cone-beam computed tomography
    Schaly, B.
    Varchena, V.
    Au, P.
    Pang, G.
    MEDICAL PHYSICS, 2006, 33 (07) : 2658 - 2658
  • [6] Cone-beam megavoltage computed tomography using ART-type reconstruction methods
    Hampton, C
    Munley, M
    Bourland, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1474 - 1474
  • [7] Megavoltage Cone-Beam Computed Tomography Using 2.5MV X-Rays
    Tang, G.
    Kirov, A.
    Lim, S.
    Seppi, E.
    Morf, D.
    Thieme, S.
    Moussot, C.
    Amols, H.
    MEDICAL PHYSICS, 2010, 37 (06) : 3443 - +
  • [8] Cone-beam Computed Tomography Image Pretreatment and Segmentation
    Zheng, Jia
    Zhang, Dinghua
    Huang, Kuidong
    Sun, Yuanxi
    2018 11TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID), VOL 1, 2018, : 25 - 28
  • [9] Characterizing a novel scintillating glass for application to megavoltage cone-beam computed tomography
    Hu, Yue-Houng
    Shedlock, Daniel
    Wang, Adam
    Rottmann, Joerg
    Baturin, Paul
    Myronakis, Marios
    Huber, Pascal
    Fueglistaller, Rony
    Shi, Mengying
    Morf, Daniel
    Star-Lack, Josh
    Berbeco, Ross I.
    MEDICAL PHYSICS, 2019, 46 (03) : 1323 - 1330
  • [10] Evaluation of Megavoltage Cone-Beam Computed Tomography Doses in Thoracic Radiation Therapy
    Yan, S.
    Zhu, J.
    Yan, S.
    MEDICAL PHYSICS, 2021, 48 (06)