Is measurement of cervical length an accurate predictive tool in women with a history of preterm delivery who present with threatened preterm labor?

被引:14
|
作者
Melamed, N.
Hiersch, L.
Meizner, I.
Bardin, R.
Wiznitzer, A.
Yogev, Y.
机构
[1] Helen Schneider Hosp Women, Rabin Med Ctr, IL-49100 Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
cervical length; preterm delivery; preterm labor; risk; INTACT MEMBRANES; GESTATIONAL-AGE; TRANSVAGINAL SONOGRAPHY; SINGLETON PREGNANCIES; PARTURITION SYNDROME; LIKELIHOOD RATIOS; RISK-ASSESSMENT; BIRTH;
D O I
10.1002/uog.13395
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To determine whether sonographically measured cervical length is an effective predictive tool in women with threatened preterm labor and a history of past spontaneous preterm delivery. Methods This was a retrospective cohort study of all women with singleton pregnancies who presented with preterm labor at less than 34 + 0 weeks' gestation and underwent sonographic measurement of cervical length in a tertiary medical center between 2007 and 2012. The accuracy of cervical length in predicting preterm delivery was compared between women with and those without a history of spontaneous preterm delivery. Women with risk factors for preterm delivery other than a history of preterm delivery were excluded from both groups. Results Overall, 1023 women who presented with preterm labor met the study criteria, of whom 136 (13.3%) had a history of preterm delivery (past-PTD group) and 887 (86.7%) had no risk factors for preterm delivery (low-risk group). The rate of preterm delivery was significantly higher for women with a history of preterm delivery (36.8% vs 22.5%; P<0.001). Cervical length was significantly correlated with the examination-to-delivery interval in low-risk women (r = 0.32, P < 0.001) but not in women who had had a previous preterm delivery (r = 0.07, P = 0.4). On multivariable analysis, cervical length was independently associated with the risk of preterm delivery for women in the low-risk group but not for women with a history of previous preterm delivery. For women with previous preterm delivery who presented with threatened preterm labor, cervical length failed to distinguish between those who did and those who did not deliver prematurely (area under the receiver-operating characteristics curve range, 0.475-0.506). When using standardized thresholds, the sensitivity and specificity of cervical length for the prediction of preterm delivery were significantly lower in women with previous preterm delivery than in women with no risk factors for preterm delivery. Conclusion Cervical length appears to be of limited value in the prediction of preterm delivery among women with threatened preterm labor who are at high risk for preterm delivery owing to a history of spontaneous preterm delivery in a previous pregnancy. Copyright (c) 2014 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 50 条
  • [1] The role of cervical length measurement for preterm delivery prediction in women with cervical dilatation who present with threatened preterm labor
    Hiersch, Liran
    Ashwal, Eran
    Melamed, Nir
    Bardin, Ron
    Aviram, Amir
    Meizner, Israel
    Wiznitzer, Arnon
    Yogev, Yariv
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S223 - S223
  • [2] Role of Cervical Length Measurement for Preterm Delivery Prediction in Women With Threatened Preterm Labor and Cervical Dilatation
    Hiersch, Liran
    Melamed, Nir
    Aviram, Amir
    Bardin, Ron
    Yogev, Yariv
    Ashwal, Eran
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (12) : 2631 - 2640
  • [3] Predictive Value of Cervical Length in Women With Threatened Preterm Labor
    Melamed, Nir
    Hiersch, Liran
    Domniz, Noam
    Maresky, Akiva
    Bardin, Ron
    Yogev, Yariv
    OBSTETRICS AND GYNECOLOGY, 2013, 122 (06): : 1279 - 1287
  • [4] Prediction of time of delivery using cervical length measurement in women with threatened preterm labor
    Ho, Nicole
    Liu, Cathy
    Anh Nguyen
    Lehner, Christoph
    Amoako, Akwasi
    Sekar, Renuka
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2021, 34 (16): : 2649 - 2654
  • [5] The predictive accuracy of cervical length in women with threatened preterm-labor
    Hiersch, Liran
    Melamed, Nir
    Bardin, Ron
    Hadar, Eran
    Wiznitzer, Arnon
    Yogev, Yariv
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S400 - S401
  • [6] Predictive Value of Cervical Length Measurement and Fibronectin Testing in Threatened Preterm Labor
    van Baaren, Gert-Jan
    Vis, Jolande Y.
    Wilms, Femke F.
    Oudijk, Martijn A.
    Kwee, Anneke
    Porath, Martina M.
    Oei, Guid
    Scheepers, Hubertina C. J.
    Spaanderman, Marc E. A.
    Bloemenkamp, Kitty W. M.
    Haak, Monique C.
    Bolte, Antoinette C.
    Bax, Caroline J.
    Cornette, Jerome M. J.
    Duvekot, Johannes J.
    Bijvanck, Bas W. A. Nij
    van Eyck, Jim
    Franssen, Maureen T. M.
    Sollie, Krystyna M.
    Vandenbussche, Frank P. H. A.
    Woiski, Mallory
    Grobman, William A.
    van der Post, Joris A. M.
    Bossuyt, Patrick M. M.
    Opmeer, Brent C.
    Mol, Ben W. J.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 (06): : 1185 - 1192
  • [7] Predictive value of cervical length in women with twin pregnancy presenting with threatened preterm labor
    Melamed, N.
    Hiersch, L.
    Gabbay-Benziv, R.
    Bardin, R.
    Meizner, I.
    Wiznitzer, A.
    Yogev, Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (01) : 73 - 81
  • [8] Repeat Measurement of Cervical Length inWomen with Threatened Preterm Labor
    Wagner, P.
    Sonek, J.
    Heidemeyer, M.
    Schmid, M.
    Abele, H.
    Hoopmann, M.
    Kagan, K. O.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2016, 76 (07) : 779 - 784
  • [9] Uterocervical Angle and Cervical Length as a Tool to Predict Preterm Birth in Threatened Preterm Labor
    Luechathananon, Sireethorn
    Songthamwat, Metha
    Chaiyarach, Sukanya
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2021, 13 : 153 - 159
  • [10] Cervilenz assessment of cervical length compared to fetal fibronectin in the prediction of preterm delivery in women with threatened preterm labor
    Burwick, Richard M.
    Zork, Noelia M.
    Lee, Gene T.
    Ross, Michael G.
    Kjos, Siri L.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2011, 24 (01): : 127 - 131