Dosimetric and radiobiological comparison of Cyberknife and Tomotherapy in stereotactic body radiotherapy for localized prostate cancer

被引:10
|
作者
Chen, Chun-You [1 ]
Lee, Liang-Ming [2 ]
Yu, Hsiao-Wei [3 ]
Lee, Steve P. [4 ]
Lee, Hsin-Lun [3 ]
Lin, Yung-Wei [2 ]
Wen, Yu-Ching [2 ]
Chen, Yi-Ju [1 ]
Chen, Chiu-Ping [1 ]
Tsai, Jo-Ting [5 ]
机构
[1] Taipei Med Univ, Wan Fang Hosp, Dept Radiat Oncol, Taipei, Taiwan
[2] Taipei Med Univ, Dept Urol, Wan Fang Hosp, Taipei, Taiwan
[3] Taipei Med Univ Hosp, Dept Radiat Oncol, Taipei, Taiwan
[4] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[5] Taipei Med Univ, Shuang Ho Hosp, Dept Radiat Oncol, Taipei, Taiwan
关键词
Stereotactic body radiation therapy (SBRT); prostate cancer; equivalent uniform dose (EUD); normal tissue complication probability (NTCP); cyberknife; tomotherapy; INTENSITY-MODULATED RADIOTHERAPY; CONFORMAL RADIATION-THERAPY; LINEAR-QUADRATIC MODEL; HELICAL TOMOTHERAPY; PROBABILITY-MODELS; DOSE-DISTRIBUTION; ALPHA/BETA RATIO; CLINICAL-TRIAL; FRACTIONS; PHASE-II;
D O I
10.3233/XST-16169
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND AND PURPOSE: As recent studies have suggested relatively low alpha/beta for prostate cancer, the interest in hypofractionated stereotactic body radiotherapy (SBRT) for prostate cancer is rising. The aim of this study is to compare dosimetric results of Cyberknife (CK) with Tomotherapy (HT) in SBRT for localized prostate cancer. Furthermore, the radiobiologic consequences of heterogeneous dose distribution are also analyzed. MATERIAL AND METHOD: A total of 12 cases of localized prostate cancer previously treated with SBRT were collected. Treatments had been planned and delivered using CK. Then HT plans were generated for comparison afterwards. The prescribed dose was 37.5Gy in 5 fractions. Dosimetric indices for target volumes and organs at risk (OAR) were compared. For radiobiological evaluation, generalized equivalent uniform dose (gEUD) and normal tissue complication probability (NTCP) were calculated and compared. RESULT: Both CK and HT achieved target coverage while meeting OAR constraints adequately. HT plans resulted in better dose homogeneity (Homogeneity index: 1.04 +/- 0.01 vs. 1.21 +/- 0.01; p = 0.0022), target coverage (97.74 +/- 0.86% vs. 96.56 +/- 1.17%; p = 0.0076) and conformity (new vonformity index: 1.16 +/- 0.05 vs. 1.21 +/- 0.04; p = 0.0096). HT was shown to predict lower late rectal toxicity as compared to CK. Integral dose to body was also significantly lower in HT plans (46.59 +/- 6.44 Gy'L vs 57.05 +/- 11.68 Gy'L; p = 0.0029). CONCLUSION: Based on physical dosimetry and radiobiologic considerations, HT may have advantages over CK, specifically in rectal sparing which could translate into clinical benefit of decreased late toxicities.
引用
收藏
页码:465 / 477
页数:13
相关论文
共 50 条
  • [1] Dosimetric Comparison of Stereotactic Body Radiotherapy for Spinal Metastasis in Cyberknife and Helical Tomotherapy
    Kang, Young-nam
    Kay, Chul Seung
    Son, Seok Hyun
    Choi, Byung Ock
    Jung, Ji-Young
    Shin, Hun-Joo
    Kay, Chul Seung
    Son, Seok Hyun
    Kim, Myong Ho
    Seo, Jae-Hyuk
    Lee, Gi Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2049 - 2053
  • [2] Dosimetric comparison of stereotactic body radiotherapy for spinal metastasis in cyberknife and helical tomotherapy
    Young-nam Kang
    Chul Seung Kay
    Seok Hyun Son
    Byung Ock Choi
    Ji-Young Jung
    Hun-Joo Shin
    Chul Seung Kay
    Seok Hyun Son
    Myong Ho Kim
    Jae-Hyuk Seo
    Gi Woong Lee
    Journal of the Korean Physical Society, 2012, 61 : 2049 - 2053
  • [3] Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer
    Zhi-tao Dai
    Li Ma
    Ting-ting Cao
    Lian Zhu
    Man Zhao
    Ning Li
    Scientific Reports, 11
  • [4] Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer
    Dai, Zhi-tao
    Ma, Li
    Cao, Ting-ting
    Zhu, Lian
    Zhao, Man
    Li, Ning
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [5] Stereotactic body radiotherapy using a hydrogel spacer for localized prostate cancer: A dosimetric comparison between tomotherapy with the newly-developed tumor-tracking system and cyberknife
    Manabe, Yoshihiko
    Hashimoto, Seiji
    Mukouyama, Hideki
    Shibamoto, Yuta
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 66 - 72
  • [6] Stereotactic radiotherapy with cyberknife® system in localized prostate cancer
    Falivene, S.
    Borzillo, V.
    Di Franco, R.
    Totaro, G.
    Ravo, V.
    Quarto, G.
    Sorrentino, D.
    Perdona, S.
    Muto, P.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S715 - S716
  • [7] Dosimetric and radiobiological comparison of TomoTherapy and IMRT plans for prostate cancer
    Pourfarshid, Amin
    Mesbahi, Asghar
    Mohammadzadeh, Mohammad
    Molazadeh, Mikaeil
    Zeinali, Ahad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [8] Dosimetric comparison among cyberknife, helical tomotherapy and VMAT for hypofractionated treatment in localized prostate cancer
    Serra, Marcello
    Ametrano, Gianluca
    Borzillo, Valentina
    Quarto, Maria
    Muto, Matteo
    Di Franco, Rossella
    Federica, Savino
    Loffredo, Filomena
    Paolo, Muto
    MEDICINE, 2020, 99 (50) : E23574
  • [9] Stereotactic Body Radiotherapy Using a Hydrogel Spacer for Localized Prostate Cancer: A Dosimetric Study Between Tomotherapy With the Newly-Developed Tumor-Tracking System and CyberKnife
    Manabe, Y.
    Hashimoto, S.
    Mukouyama, H.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E277 - E277
  • [10] Stereotactic Body Radiotherapy in Localized Prostate Cancer
    Kashihara, Tairo
    van As, Nicholas
    Patel, Jaymini
    Hall, Emma
    NEW ENGLAND JOURNAL OF MEDICINE, 2025, 392 (02): : 206 - 207